{"product_id":"physiological-data-recording-unit-maclab-4e-adinstruments","title":"MacLab\/4e ADInstruments High Performance Recording Unit","description":"\u003ch2 data-start=\"385\" data-end=\"495\"\u003e\u003cstrong data-start=\"388\" data-end=\"495\"\u003eHigh Performance Recording Unit: ADInstruments MacLab\/4e High Performance 4-Channel Data Recording Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"497\" data-end=\"579\"\u003e\u003cstrong data-start=\"501\" data-end=\"579\"\u003eProfessional 4-Channel Recording Unit for Physiological Signal Acquisition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"581\" data-end=\"927\"\u003eThe \u003cstrong data-start=\"585\" data-end=\"645\"\u003eHigh Performance Recording Unit: ADInstruments MacLab\/4e\u003c\/strong\u003e is a robust 4-channel data acquisition system designed for precise biological and physiological signal recording. Built for research, teaching, and experimental applications, this \u003cstrong data-start=\"826\" data-end=\"861\"\u003ehigh performance recording unit\u003c\/strong\u003e captures real-time data with exceptional clarity and stability.\u003c\/p\u003e\n\u003cp data-start=\"929\" data-end=\"1281\"\u003eEquipped with \u003cstrong data-start=\"943\" data-end=\"985\"\u003epositive and negative output terminals\u003c\/strong\u003e and a \u003cstrong data-start=\"992\" data-end=\"1017\"\u003eBNC trigger connector\u003c\/strong\u003e, the \u003cstrong data-start=\"1023\" data-end=\"1065\"\u003eADInstruments MacLab\/4e Recording Unit\u003c\/strong\u003e integrates easily with other lab systems for synchronised data capture. It supports \u003cstrong data-start=\"1150\" data-end=\"1162\"\u003ePowerLab\u003c\/strong\u003e and \u003cstrong data-start=\"1167\" data-end=\"1179\"\u003eLabChart\u003c\/strong\u003e environments, providing seamless compatibility for biomedical and physiological research workflows.\u003c\/p\u003e\n\u003cp data-start=\"1283\" data-end=\"1565\"\u003eThis pre-owned \u003cstrong data-start=\"1298\" data-end=\"1316\"\u003eMacLab\/4e unit\u003c\/strong\u003e has been fully tested and verified in excellent condition, ensuring reliable performance for educational and professional laboratories. Compact and rack-mountable, it fits neatly into modern lab setups where space efficiency and precision matter.\u003c\/p\u003e\n\u003chr data-start=\"1567\" data-end=\"1570\"\u003e\n\u003ch3 data-start=\"1572\" data-end=\"1603\"\u003e\u003cstrong data-start=\"1576\" data-end=\"1603\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1605\" data-end=\"2129\"\u003e\n\u003cli data-start=\"1605\" data-end=\"1699\"\u003e\n\u003cp data-start=\"1607\" data-end=\"1699\"\u003e\u003cstrong data-start=\"1607\" data-end=\"1634\"\u003e4 Independent Channels:\u003c\/strong\u003e Acquire multiple signals simultaneously for accurate analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1791\"\u003e\u003cstrong data-start=\"1702\" data-end=\"1734\"\u003ePositive \u0026amp; Negative Outputs:\u003c\/strong\u003e Enhanced flexibility for advanced experimental design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1872\"\u003e\n\u003cp data-start=\"1794\" data-end=\"1872\"\u003e\u003cstrong data-start=\"1794\" data-end=\"1820\"\u003eTrigger BNC Connector:\u003c\/strong\u003e Allows synchronisation with external lab devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1873\" data-end=\"1947\"\u003e\n\u003cp data-start=\"1875\" data-end=\"1947\"\u003e\u003cstrong data-start=\"1875\" data-end=\"1910\"\u003eCompact, Rack-Mountable Design:\u003c\/strong\u003e Fits standard lab equipment racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1948\" data-end=\"2038\"\u003e\n\u003cp data-start=\"1950\" data-end=\"2038\"\u003e\u003cstrong data-start=\"1950\" data-end=\"1977\"\u003eSoftware Compatibility:\u003c\/strong\u003e Works with ADInstruments LabChart (software not included).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2039\" data-end=\"2129\"\u003e\n\u003cp data-start=\"2041\" data-end=\"2129\"\u003e\u003cstrong data-start=\"2041\" data-end=\"2059\"\u003eTrusted Brand:\u003c\/strong\u003e Widely used in biomedical, physiological, and educational research.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2131\" data-end=\"2134\"\u003e\n\u003ch3 data-start=\"2136\" data-end=\"2168\"\u003e\u003cstrong data-start=\"2140\" data-end=\"2168\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2170\" data-end=\"2715\"\u003e\n\u003cthead data-start=\"2170\" data-end=\"2205\"\u003e\n\u003ctr data-start=\"2170\" data-end=\"2205\"\u003e\n\u003cth data-start=\"2170\" data-end=\"2190\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2172\" data-end=\"2189\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2190\" data-end=\"2205\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2192\" data-end=\"2203\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2243\" data-end=\"2715\"\u003e\n\u003ctr data-start=\"2243\" data-end=\"2275\"\u003e\n\u003ctd data-start=\"2243\" data-end=\"2258\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"2258\" data-end=\"2275\" data-col-size=\"md\"\u003eADInstruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2276\" data-end=\"2297\"\u003e\n\u003ctd data-start=\"2276\" data-end=\"2284\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2284\" data-end=\"2297\" data-col-size=\"md\"\u003eMacLab\/4e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2298\" data-end=\"2340\"\u003e\n\u003ctd data-start=\"2298\" data-end=\"2310\" data-col-size=\"sm\"\u003eCondition\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2310\" data-end=\"2340\"\u003eUsed – Excellent Condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2341\" data-end=\"2381\"\u003e\n\u003ctd data-start=\"2341\" data-end=\"2352\" data-col-size=\"sm\"\u003eChannels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2352\" data-end=\"2381\"\u003e4 analogue input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2382\" data-end=\"2427\"\u003e\n\u003ctd data-start=\"2382\" data-end=\"2392\" data-col-size=\"sm\"\u003eOutputs\u003c\/td\u003e\n\u003ctd data-start=\"2392\" data-end=\"2427\" data-col-size=\"md\"\u003ePositive and negative terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2428\" data-end=\"2461\"\u003e\n\u003ctd data-start=\"2428\" data-end=\"2444\" data-col-size=\"sm\"\u003eTrigger Input\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2444\" data-end=\"2461\"\u003eBNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2462\" data-end=\"2514\"\u003e\n\u003ctd data-start=\"2462\" data-end=\"2478\" data-col-size=\"sm\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2478\" data-end=\"2514\"\u003eMac and earlier PowerLab systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2515\" data-end=\"2564\"\u003e\n\u003ctd data-start=\"2515\" data-end=\"2526\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2526\" data-end=\"2564\"\u003eLabChart compatible (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2565\" data-end=\"2613\"\u003e\n\u003ctd data-start=\"2565\" data-end=\"2580\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2580\" data-end=\"2613\"\u003eStandard AC, region-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2614\" data-end=\"2662\"\u003e\n\u003ctd data-start=\"2614\" data-end=\"2628\" data-col-size=\"sm\"\u003eAccessories\u003c\/td\u003e\n\u003ctd data-start=\"2628\" data-end=\"2662\" data-col-size=\"md\"\u003eNone included unless specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2663\" data-end=\"2715\"\u003e\n\u003ctd data-start=\"2663\" data-end=\"2669\" data-col-size=\"sm\"\u003eUse\u003c\/td\u003e\n\u003ctd data-start=\"2669\" data-end=\"2715\" data-col-size=\"md\"\u003eEducation, biomedical, physiology research\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2717\" data-end=\"2720\"\u003e\n\u003ch3 data-start=\"2722\" data-end=\"2749\"\u003e\u003cstrong data-start=\"2726\" data-end=\"2749\"\u003eIncluded Components\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2751\" data-end=\"2888\"\u003e\n\u003cli data-start=\"2751\" data-end=\"2812\"\u003e\n\u003cp data-start=\"2753\" data-end=\"2812\"\u003e1 × ADInstruments MacLab\/4e 4-Channel Data Recording Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2813\" data-end=\"2888\"\u003e\n\u003cp data-start=\"2815\" data-end=\"2888\"\u003eUnit only (no leads, software, or documentation included unless stated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2890\" data-end=\"2893\"\u003e\n\u003ch3 data-start=\"2895\" data-end=\"2912\"\u003e\u003cstrong data-start=\"2899\" data-end=\"2912\"\u003eIdeal For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2914\" data-end=\"3103\"\u003e\n\u003cli data-start=\"2914\" data-end=\"2954\"\u003e\n\u003cp data-start=\"2916\" data-end=\"2954\"\u003ePhysiology and pharmacology research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2955\" data-end=\"3001\"\u003e\n\u003cp data-start=\"2957\" data-end=\"3001\"\u003eBiomedical signal and waveform acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3002\" data-end=\"3049\"\u003e\n\u003cp data-start=\"3004\" data-end=\"3049\"\u003eTeaching laboratories using PowerLab setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3050\" data-end=\"3103\"\u003e\n\u003cp data-start=\"3052\" data-end=\"3103\"\u003eCustom data recording and synchronisation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ADInstruments","offers":[{"title":"Default Title","offer_id":54992751460677,"sku":"MAL151901","price":99.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/ADInstruments_MacLab_4e_close-up_showing_four_input_ports.jpg?v=1767164223","url":"https:\/\/selfimed.com\/de\/products\/physiological-data-recording-unit-maclab-4e-adinstruments","provider":"SelfiMed UK","version":"1.0","type":"link"}