{"product_id":"exergen-calibration-verification-kit-thermometer-bundle","title":"Exergen Calibration Verification Kit with Two TAT-5000S and Two TAT-5000 Temporal Artery Thermometers","description":"\u003c!-- ═══════════════════════════════════ SECTION 1 : DESCRIPTION, REFERENCES, FEATURES, NOTICES ═══════════════════════════════════ --\u003e\n\u003ch2\u003eExergen Calibration Verification Kit with Two TAT-5000S and Two TAT-5000 Temporal Artery Thermometers, Pre-owned\u003c\/h2\u003e\n\u003cp\u003eAn Exergen calibration verification kit, part 129062, supplied with four TemporalScanner infrared temporal artery thermometers: two of the current TAT-5000S and two of the preceding TAT-5000. The kit holds a certified master reference thermometer, a portable handheld blackbody target and a mains supply with international adapter blades, in a rugged case, and it verifies thermometers against the master on the bench rather than sending them away.\u003c\/p\u003e\n\u003cp\u003eThis is what turns a set of thermometers into a managed estate. A clinical thermometer is a measuring instrument, and an instrument whose accuracy nobody has checked is an instrument nobody should be charting from. Exergen's answer is a portable blackbody held at body temperature, between 36 and 40 degrees Celsius, and a certified master thermometer kept alongside it. Both the master and the instrument under test read the same target in turn, and the two figures are compared. A TAT-5000 or TAT-5000S passes if it agrees with the master within 0.2 degrees Celsius.\u003c\/p\u003e\n\u003cp\u003eThe procedure is deliberately undramatic, which is why a ward can run it. The verifier warms up for about five minutes, the thermometers sit in the same room for at least ten so everything is at one temperature, every lens including the master's is wiped with an alcohol swab, and readings are then taken alternately. On a large batch the master is re-read about every ten instruments so its own drift does not go unnoticed. Exergen note that a dirty lens is the commonest cause of a low reading, so a cleaning and a repeat comes before any conclusion that an instrument has failed.\u003c\/p\u003e\n\u003cp\u003eThe kit covers the whole TemporalScanner family rather than one generation, which is why a mixed set like this one works with it: Exergen list the TAT-2000, TAT-2000C, TAT-5000 and TAT-5000S as applicable models. The two TAT-5000S units are the current generation, released as the successor to the TAT-5000 with the same stated accuracy and a revised housing, and all four read to 0.1 degrees Celsius with a clinical accuracy of plus or minus 0.1 degrees Celsius to ASTM E1112.\u003c\/p\u003e\n\u003ch3\u003eReferences\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExergen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration verification kit, part 129062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermometers supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo TemporalScanner TAT-5000S and two TemporalScanner TAT-5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVerification principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComparison against a certified master reading a blackbody target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlackbody target range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 to 40 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePass tolerance for the 5000 series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin 0.2 degrees Celsius of the certified master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplicable models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTAT-2000, TAT-2000C, TAT-5000 and TAT-5000S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermometer accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlus or minus 0.1 degrees Celsius, to ASTM E1112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerification carried out on the bench, so instruments are not sent away to be checked.\u003c\/li\u003e\n\u003cli\u003eCertified master reference thermometer, held as the comparison standard.\u003c\/li\u003e\n\u003cli\u003ePortable handheld blackbody target, model PBB-1, held at body temperature.\u003c\/li\u003e\n\u003cli\u003ePass tolerance of 0.2 degrees Celsius for the TAT-5000 and TAT-5000S.\u003c\/li\u003e\n\u003cli\u003eCovers the whole TemporalScanner family, including the TAT-2000 series at a 0.3 degrees Celsius tolerance.\u003c\/li\u003e\n\u003cli\u003eMains supply with adapter blades for United Kingdom, European and other outlets.\u003c\/li\u003e\n\u003cli\u003eRuns on a 9 V alkaline battery for around five hours, or from the mains supply at 90 to 264 V.\u003c\/li\u003e\n\u003cli\u003eIndicator light that goes out when the battery falls too low to give a valid comparison.\u003c\/li\u003e\n\u003cli\u003eRugged storage case holding the whole kit together.\u003c\/li\u003e\n\u003cli\u003eFour thermometers supplied, two of each generation.\u003c\/li\u003e\n\u003cli\u003eAll four reading to 0.1 degrees Celsius with a clinical accuracy of plus or minus 0.1 degrees Celsius.\u003c\/li\u003e\n\u003cli\u003eEnough instruments and the means to check them for a small department in one purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #fff3cd; border-left: 5px solid #ffc107; padding: 16px 20px; margin: 0 0 22px; border-radius: 4px;\"\u003e\n\u003cp\u003e\u003cstrong style=\"color: #856404;\"\u003ePoints to note before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExergen calibrate these instruments two ways, arterial and oral equivalent, and the kit only verifies thermometers of the same type as its certified master: the serial numbers carry the letter A or O and both master and instrument under test must match, so the prefixes on the master and on all four thermometers are read before the set is relied on as a working whole. The certified master itself is a dated instrument, recertified by Exergen annually against the sticker on it, and the verifier carries a one year certification of its own, so a kit whose dates have passed will need recertifying before it can support a quality assurance record, which is a matter for the receiving organisation rather than something that can be judged from the outside. Scale matters too, since Exergen build the thermometers in Fahrenheit and preset Celsius versions and a United Kingdom ward needs Celsius, though the master itself switches between the two on a switch inside its battery compartment. In use the verifier warms for around five minutes, the instruments equilibrate in the same room for at least ten, every lens is cleaned with an alcohol swab, probe covers and sheaths are left off during verification, and a thermometer that reads outside tolerance is cleaned and re-read before it is judged, a dirty lens being the commonest reason for a low figure; recalibration itself is a factory operation rather than a field adjustment. The kit and its contents are wiped with alcohol or a mild cleaning solution and never immersed.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- ═══════════════════════════════════ SECTION 2 : TECHNICAL SPECIFICATION ═══════════════════════════════════ --\u003e","brand":"Exergen","offers":[{"title":"VAT excluded","offer_id":60408864735557,"sku":"EXE4220V","price":499.99,"currency_code":"GBP","in_stock":true},{"title":"VAT included","offer_id":60408864768325,"sku":"EXE4221V","price":499.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/images_63f4d62f-7e40-43f2-8ee5-cf15a4912bb7.jpg?v=1795618506","url":"https:\/\/selfimed.com\/fi\/products\/exergen-calibration-verification-kit-thermometer-bundle","provider":"SelfiMed UK","version":"1.0","type":"link"}