{"product_id":"vital-signs-monitor-suntech-ct40-nibp-spo2-temperature","title":"Suntech CT40 Vital Signs Monitor in a Box","description":"\u003cstyle\u003e\n.pw{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;color:#212529;line-height:1.65;font-size:16px;max-width:1000px}\n.pw h2{font-size:26px;line-height:1.3;font-weight:700;color:#1b4f72;margin:0 0 18px}\n.pw h3{font-size:20px;font-weight:700;color:#1b4f72;margin:32px 0 14px}\n.pw p{margin:0 0 16px}\n.pw ul{margin:0 0 16px;padding-left:22px}\n.pw li{margin:0 0 8px}\n.pw-intro{background:#eaf2f8;border-left:5px solid #1b4f72;padding:18px 20px;margin:0 0 26px;border-radius:4px}\n.pw-intro p:last-child{margin-bottom:0}\n.pw-table{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-table th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700;font-size:15px}\n.pw-table.pw-excluded th{background:#6c757d}\n.pw-table td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-table tr:nth-child(even) td{background:#f8f9fa}\n.pw-badge{display:inline-block;padding:3px 9px;border-radius:3px;font-size:12px;font-weight:700;letter-spacing:.3px;white-space:nowrap}\n.pw-new{background:#d4edda;color:#155724}\n.pw-used{background:#fff3cd;color:#856404}\n.pw-sold{background:#f8d7da;color:#721c24}\n.pw-addon{background:#e2d9f3;color:#4a1d96}\n.pw-box{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 14px}\n.pw-box strong{color:#1b4f72}\n.pw-specs{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-specs th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-specs td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-specs td:first-child{font-weight:600;width:34%;background:#f8f9fa}\n.pw-note{background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-note strong{color:#856404}\n.pw-note p:last-child,.pw-note ul:last-child{margin-bottom:0}\n.pw-alert{background:#eaf2f8;border-left:5px solid #1b4f72;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-alert strong{color:#1b4f72}\n.pw-alert p:last-child,.pw-alert ul:last-child{margin-bottom:0}\n.pw-schedule{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-schedule th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-schedule td{border:1px solid #dee2e6;padding:11px 14px}\n.pw-schedule tr:nth-child(even) td{background:#f8f9fa}\n.pw-media{margin:0 0 26px;text-align:center}\n.pw-media img{max-width:100%;height:auto;border:1px solid #dee2e6;border-radius:5px}\n.pw-docs{list-style:none;margin:0 0 26px;padding:0}\n.pw-docs li{margin:0 0 10px}\n.pw-docs a{display:inline-flex;align-items:center;gap:10px;color:#1b4f72;font-weight:600;text-decoration:none}\n.pw-docs a:hover{text-decoration:underline}\n.pw-docs svg{flex:0 0 auto}\n.pw-video-wrap{position:relative;padding-bottom:56.25%;height:0;overflow:hidden;margin:0 0 26px;border-radius:5px}\n.pw-video-wrap iframe{position:absolute;top:0;left:0;width:100%;height:100%;border:0}\n@media(max-width:600px){.pw h2{font-size:22px}.pw-table,.pw-specs,.pw-schedule{font-size:14px}.pw-specs td:first-child{width:42%}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"pw\"\u003e\n\n\u003ch2\u003eSunTech CT40 Vital Signs Monitor, Pre-Owned, Complete with Accessories, NIBP, SpO2 and Temperature\u003c\/h2\u003e\n\n\u003cdiv class=\"pw-intro\"\u003e\n\u003cp\u003eThe SunTech CT40 is a spot-check vital signs device measuring brachial blood pressure, heart rate, oxygen saturation and body temperature in patients from three years of age through to adults. It runs SunTech Advantage oscillometric blood pressure technology, the same measurement platform used in clinical trial and research settings, which is what separates it from a general purpose observations machine. Its distinguishing feature is a modular build: the pulse oximetry and thermometry modules can be added or changed in the field rather than sending the device away. Supplied here with its accessories in a box, ready for clinic, ward and outreach use. No trolley or rollstand is included, so the device sits on a desk, worktop or existing stand.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSunTech CT40 device\u003c\/td\u003e\n\u003ctd\u003eSpot-check vital signs device, model 260, with fitted modules\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply and lead\u003c\/td\u003e\n\u003ctd\u003eMains power supply for the device\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlood pressure cuff and hose\u003c\/td\u003e\n\u003ctd\u003eCuff and connecting hose as supplied in the box\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO2 sensor and cable\u003c\/td\u003e\n\u003ctd\u003eFinger sensor and interface cable for the fitted oximetry module\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature probe\u003c\/td\u003e\n\u003ctd\u003eProbe for the fitted thermometry module\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table pw-excluded\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe covers\u003c\/td\u003e\n\u003ctd\u003eSingle-use covers for contact thermometry, a consumable\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional cuff sizes\u003c\/td\u003e\n\u003ctd\u003eSmall adult, large adult, thigh and paediatric cuffs\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare SpO2 sensors\u003c\/td\u003e\n\u003ctd\u003eSensors matched to the fitted oximetry module\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRollstand or mobile trolley\u003c\/td\u003e\n\u003ctd\u003eStand, trolley or wall bracket for the device\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi adapter\u003c\/td\u003e\n\u003ctd\u003eOptional wireless connectivity hardware\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarcode scanner\u003c\/td\u003e\n\u003ctd\u003ePatient and operator identification accessory\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork integration\u003c\/td\u003e\n\u003ctd\u003eHL7 and IHE configuration into a clinical record system\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and calibration\u003c\/td\u003e\n\u003ctd\u003eEngineer service, accuracy verification and certification\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eChecked before dispatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaned and inspected.\u003c\/li\u003e\n\u003cli\u003ePowered up and function tested across the fitted parameters.\u003c\/li\u003e\n\u003cli\u003eCuff, hose, sensor and probe leads checked for splits, kinks and secure connection.\u003c\/li\u003e\n\u003cli\u003eMains lead and plug visually inspected for damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service and calibration is not included unless this listing states that the unit has been serviced. Verification of measurement accuracy against a calibrated reference, planned maintenance and periodic electrical safety testing remain with the operating organisation once the device is in service.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eClinical use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor use by a qualified clinician. The device measures, records and displays. It does not make a diagnosis.\u003c\/li\u003e\n\u003cli\u003eBlood pressure accuracy depends on cuff size. A cuff that is too small overestimates and one that is too large underestimates, so the cuff must be matched to the arm rather than to what is already on the machine.\u003c\/li\u003e\n\u003cli\u003eSensors and probes must match the fitted module. Oximetry sensors from a different module family will not read correctly, and contact thermometry must not be used without a fresh probe cover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eAdvantage blood pressure technology\u003c\/strong\u003e, SunTech's clinical grade oscillometric platform, giving the measurement quality expected of a research and trial device rather than a consumer machine.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eModular design\u003c\/strong\u003e allowing the pulse oximetry and thermometry modules to be added or changed on site, so the device can be reconfigured as caseload changes without going back to the manufacturer.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eManual SphygMode\u003c\/strong\u003e for real-time verification of a blood pressure reading without removing the cuff, which settles the question when an automated result looks wrong.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBlood pressure averaging mode\u003c\/strong\u003e, a configurable protocol that takes a series of readings and averages them, the approach recommended for accurate hypertension assessment.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eThree parameters in one device\u003c\/strong\u003e, covering non-invasive blood pressure, heart rate, oxygen saturation and body temperature.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003ePaediatric and adult use\u003c\/strong\u003e from three years of age upward, with separate adult and paediatric pressure ranges.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBuilt-in Ethernet\u003c\/strong\u003e with optional Wi-Fi, and data transfer under HL7 and IHE protocols into a clinical record system.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eMounting options\u003c\/strong\u003e across desk, wall bracket, rollstand and mobile trolley, all available separately, so the device can be fixed in a clinic room or moved between bays as the service requires.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCompact device at approximately 1.44 kg\u003c\/strong\u003e without battery, so it lifts off the stand for outreach work and home visits.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eSimple two-button measurement interface\u003c\/strong\u003e with an LCD display, which keeps training time short across a rotating team.\u003c\/div\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\n\u003ctable class=\"pw-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSunTech Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCT40, model 260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eSpot-check vital signs device, oscillometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameters\u003c\/td\u003e\n\u003ctd\u003eNon-invasive blood pressure, heart rate, SpO2, body temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient population\u003c\/td\u003e\n\u003ctd\u003eChildren from 3 years of age through to adults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystolic range\u003c\/td\u003e\n\u003ctd\u003e40 to 260 mmHg adult, 40 to 230 mmHg paediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiastolic range\u003c\/td\u003e\n\u003ctd\u003e20 to 200 mmHg adult, 20 to 160 mmHg paediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlood pressure technology\u003c\/td\u003e\n\u003ctd\u003eSunTech Advantage, with Manual SphygMode and averaging mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOximetry module\u003c\/td\u003e\n\u003ctd\u003eModular, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermometry module\u003c\/td\u003e\n\u003ctd\u003eModular, contact or touchless, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD with numeric readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Ethernet, optional Wi-Fi, HL7 and IHE data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V AC, 1.5 A maximum, 50 to 60 Hz, with internal battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 205 x 190 x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.44 kg without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDesk or worktop as supplied, stand and wall bracket options available separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse case\u003c\/td\u003e\n\u003ctd\u003eSpot-check observations in clinical settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eModule configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CT40 was supplied with a choice of pulse oximetry and thermometry modules, and consumables are specific to the module fitted. Oximetry sensors are not interchangeable between module families, and contact thermometry probes and covers differ from touchless thermometry. Ask before ordering to confirm which modules are fitted to this unit, so that sensors, probes and probe covers can be matched correctly from the outset.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCondition and history.\u003c\/strong\u003e A pre-owned unit from clinical service, cleaned and inspected. Cosmetic marking consistent with previous use should be expected. Ongoing maintenance should follow the operating organisation's medical device management policy and the duties under PUWER 1998. The photographs form part of the description and show the actual condition of the items offered.\u003c\/div\u003e\n\n\u003ch3\u003eSuited to\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eGP surgeries and ward observation rounds\u003c\/li\u003e\n\u003cli\u003eOutpatient and triage clinics\u003c\/li\u003e\n\u003cli\u003eMobile health screening units\u003c\/li\u003e\n\u003cli\u003eCommunity and field healthcare teams\u003c\/li\u003e\n\u003cli\u003eOccupational health and screening services\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRoutine care guidance\u003c\/h3\u003e\n\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuff and hose\u003c\/td\u003e\n\u003ctd\u003eInspect for splits, kinks and leaks, wipe down per local policy\u003c\/td\u003e\n\u003ctd\u003eBetween patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO2 sensor\u003c\/td\u003e\n\u003ctd\u003eCheck the emitter and detector windows are clean and the cable is undamaged\u003c\/td\u003e\n\u003ctd\u003eBetween patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature probe\u003c\/td\u003e\n\u003ctd\u003eFit a fresh probe cover for every measurement, inspect the probe tip\u003c\/td\u003e\n\u003ctd\u003eEvery measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice housing\u003c\/td\u003e\n\u003ctd\u003eWipe down per local policy, check the display and keypad for damage\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains lead and plug\u003c\/td\u003e\n\u003ctd\u003eInspect for damage and strain at the entry point\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuff sizing stock\u003c\/td\u003e\n\u003ctd\u003eConfirm the full range of cuff sizes needed for the caseload is available\u003c\/td\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy verification and electrical safety test\u003c\/td\u003e\n\u003ctd\u003eEngineer check against a calibrated reference\u003c\/td\u003e\n\u003ctd\u003ePer local schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe above is general guidance. The manufacturer instructions for use and the operating organisation's medical device management policy take precedence. Any device giving readings that do not fit the clinical picture should be taken out of service and verified before further use.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"SunTech","offers":[{"title":"Default Title","offer_id":58820856840517,"sku":"SUN3884D","price":399.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/SunTech_CT40.jpg?v=1786376799","url":"https:\/\/selfimed.com\/fi\/products\/vital-signs-monitor-suntech-ct40-nibp-spo2-temperature","provider":"SelfiMed UK","version":"1.0","type":"link"}