{"product_id":"suction-pump-eschmann-vpx35-four-canisters","title":"Eschmann VPX35 Suction Pump with 4 Canisters","description":"\u003cstyle\u003e\n.pw{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;color:#212529;line-height:1.65;font-size:16px;max-width:1000px}\n.pw h2{font-size:26px;line-height:1.3;font-weight:700;color:#1b4f72;margin:0 0 18px}\n.pw h3{font-size:20px;font-weight:700;color:#1b4f72;margin:32px 0 14px}\n.pw p{margin:0 0 16px}\n.pw ul{margin:0 0 16px;padding-left:22px}\n.pw li{margin:0 0 8px}\n.pw-intro{background:#eaf2f8;border-left:5px solid #1b4f72;padding:18px 20px;margin:0 0 26px;border-radius:4px}\n.pw-intro p:last-child{margin-bottom:0}\n.pw-table{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-table th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700;font-size:15px}\n.pw-table.pw-excluded th{background:#6c757d}\n.pw-table td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-table tr:nth-child(even) td{background:#f8f9fa}\n.pw-badge{display:inline-block;padding:3px 9px;border-radius:3px;font-size:12px;font-weight:700;letter-spacing:.3px;white-space:nowrap}\n.pw-new{background:#d4edda;color:#155724}\n.pw-used{background:#fff3cd;color:#856404}\n.pw-sold{background:#f8d7da;color:#721c24}\n.pw-addon{background:#e2d9f3;color:#4a1d96}\n.pw-box{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 14px}\n.pw-box strong{color:#1b4f72}\n.pw-specs{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-specs th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-specs td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-specs td:first-child{font-weight:600;width:34%;background:#f8f9fa}\n.pw-note{background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-note strong{color:#856404}\n.pw-note p:last-child,.pw-note ul:last-child{margin-bottom:0}\n.pw-alert{background:#eaf2f8;border-left:5px solid #1b4f72;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-alert strong{color:#1b4f72}\n.pw-alert p:last-child,.pw-alert ul:last-child{margin-bottom:0}\n.pw-schedule{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-schedule th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-schedule td{border:1px solid #dee2e6;padding:11px 14px}\n.pw-schedule tr:nth-child(even) td{background:#f8f9fa}\n.pw-media{margin:0 0 26px;text-align:center}\n.pw-media img{max-width:100%;height:auto;border:1px solid #dee2e6;border-radius:5px}\n.pw-docs{list-style:none;margin:0 0 26px;padding:0}\n.pw-docs li{margin:0 0 10px}\n.pw-docs a{display:inline-flex;align-items:center;gap:10px;color:#1b4f72;font-weight:600;text-decoration:none}\n.pw-docs a:hover{text-decoration:underline}\n.pw-docs svg{flex:0 0 auto}\n.pw-video-wrap{position:relative;padding-bottom:56.25%;height:0;overflow:hidden;margin:0 0 26px;border-radius:5px}\n.pw-video-wrap iframe{position:absolute;top:0;left:0;width:100%;height:100%;border:0}\n@media(max-width:600px){.pw h2{font-size:22px}.pw-table,.pw-specs,.pw-schedule{font-size:14px}.pw-specs td:first-child{width:42%}}\n\u003c\/style\u003e\n\u003cdiv class=\"pw\"\u003e\n\u003ch2\u003eEschmann VPX35 Advanced Portable Suction Pump with 4 Canisters, Pre-Owned\u003c\/h2\u003e\n\u003cdiv class=\"pw-intro\"\u003e\n\u003cp\u003eThe Eschmann VPX35 is a high power mobile suction unit delivering a vacuum flow rate above 35 litres per minute. It is built for theatre, treatment room and ward use where a portable unit has to match the performance of a piped supply.\u003c\/p\u003e\n\u003cp\u003eControls, handles, jars and the hydrophobic filter mount all sit at working height, so the unit is operated and changed over standing up rather than crouched over a trolley. Supplied here with four canisters. Eschmann is a UK manufacturer with a current consumables range, which matters on a used unit: liners, filters and tubing remain straightforward to source.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003ctable class=\"pw-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPX35 suction unit\u003c\/td\u003e\n\u003ctd\u003eEschmann mobile suction pump on its trolley base\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanisters\u003c\/td\u003e\n\u003ctd\u003eFour canisters as photographed\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\u003ctable class=\"pw-table pw-excluded\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrophobic bacterial filters\u003c\/td\u003e\n\u003ctd\u003eSingle-use filters, one required in place before use\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposable liners\u003c\/td\u003e\n\u003ctd\u003eLiner system consumables where the liner method is used\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction tubing\u003c\/td\u003e\n\u003ctd\u003ePatient tubing and connectors\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYankauer and suction handpieces\u003c\/td\u003e\n\u003ctd\u003eSingle-use suction tips\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanister lids and seals\u003c\/td\u003e\n\u003ctd\u003eAny lid, seal or overflow float beyond what is photographed\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic footswitch\u003c\/td\u003e\n\u003ctd\u003eFootswitch variant accessory\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and calibration\u003c\/td\u003e\n\u003ctd\u003eEngineer service, vacuum performance verification and certification\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eFit a filter before use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA hydrophobic bacterial filter must be in place at the pump inlet before the unit is used. The filter is what stops aspirated fluid reaching the pump on overflow and what prevents contaminated air passing through the exhaust.\u003c\/li\u003e\n\u003cli\u003eFilters, liners, tubing and suction tips are single-use consumables and are not supplied with this unit.\u003c\/li\u003e\n\u003cli\u003eDecontaminate the unit and the canisters in line with the receiving organisation's policy before it enters clinical service.\u003c\/li\u003e\n\u003cli\u003eCheck canisters, lids, seals and overflow protection are complete and undamaged before the unit is used on a patient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eChecked before dispatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaned and inspected.\u003c\/li\u003e\n\u003cli\u003ePowered up and function tested, with vacuum generation and the rotary suction control confirmed.\u003c\/li\u003e\n\u003cli\u003eCanisters, mountings and filter mount checked for cracks and secure fitting.\u003c\/li\u003e\n\u003cli\u003eCastors, handle, mains lead and plug visually inspected for damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service and vacuum performance verification are not included unless this listing states that the unit has been serviced. Planned maintenance and periodic electrical safety testing remain with the operating organisation once the unit is in service.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eVacuum flow rate above 35 litres per minute\u003c\/strong\u003e, high enough for surgical and procedural suction rather than airway clearance alone.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFour canisters supplied\u003c\/strong\u003e, giving a fitted pair plus spares, so a full canister is swapped out rather than emptied mid-list.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFully mobile\u003c\/strong\u003e on its own trolley base with a push handle, so the unit follows the patient between rooms.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eWorking height layout\u003c\/strong\u003e placing controls, handles, jars and the filter at a comfortable level for operation and changeover.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eHydrophobic filter mount\u003c\/strong\u003e at the pump inlet, protecting the pump from overflow and reducing cross-infection risk.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eLiner or jar working\u003c\/strong\u003e, so a department can run disposable liners for infection control or traditional canisters as protocol requires.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eSimple rotary suction control\u003c\/strong\u003e with a clear gauge, which keeps training short across a rotating team.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eEasy clean design\u003c\/strong\u003e with wipe-down surfaces suited to routine decontamination between cases.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eUK manufacturer with a current consumables range\u003c\/strong\u003e, so filters, liners and tubing for this platform remain available rather than being an obsolete part hunt.\u003c\/div\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable class=\"pw-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEschmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVPX35 advanced portable suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e8235060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eMobile electric surgical suction unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum flow rate\u003c\/td\u003e\n\u003ctd\u003eAbove 35 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanister system\u003c\/td\u003e\n\u003ctd\u003eTwin jar, compatible with disposable liners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanisters supplied\u003c\/td\u003e\n\u003ctd\u003eFour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration\u003c\/td\u003e\n\u003ctd\u003eHydrophobic bacterial filter at the pump inlet, not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction control\u003c\/td\u003e\n\u003ctd\u003eRotary control with vacuum gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobility\u003c\/td\u003e\n\u003ctd\u003eTrolley base with castors and push handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariants\u003c\/td\u003e\n\u003ctd\u003eAlso produced in a pneumatic footswitch version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eTheatres, treatment rooms, wards, clinics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification limited to what is confirmed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaximum vacuum, dimensions and weight are not stated here, because published figures for the earlier Eschmann VP35 belong to a different generation of unit and should not be applied to the VPX35. If those figures are needed before purchase, ask and the rating plate will be photographed. The current user manual covering the VPX35 and VPX45 is available from Eschmann.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCondition and history.\u003c\/strong\u003e A pre-owned unit from clinical service, cleaned and inspected. Cosmetic marking consistent with previous use should be expected. Ongoing maintenance should follow the operating organisation's medical device management policy and the duties under PUWER 1998. The photographs form part of the description and show the actual condition of the items offered.\u003c\/div\u003e\n\u003ch3\u003eRoutine care guidance\u003c\/h3\u003e\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter\u003c\/td\u003e\n\u003ctd\u003eFit a fresh hydrophobic filter, and change immediately if it becomes wet or soiled\u003c\/td\u003e\n\u003ctd\u003ePer local policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanisters and liners\u003c\/td\u003e\n\u003ctd\u003eEmpty and dispose of contents per local policy, do not fill beyond the marked level\u003c\/td\u003e\n\u003ctd\u003eBetween patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing and tips\u003c\/td\u003e\n\u003ctd\u003eFit fresh single-use tubing and suction tips\u003c\/td\u003e\n\u003ctd\u003eEvery patient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeals and lids\u003c\/td\u003e\n\u003ctd\u003eInspect for splits and distortion, confirm the seal holds vacuum\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum check\u003c\/td\u003e\n\u003ctd\u003eOcclude the patient line and confirm the gauge reaches the expected level\u003c\/td\u003e\n\u003ctd\u003eBefore each session\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing and trolley\u003c\/td\u003e\n\u003ctd\u003eWipe down per local policy, check castors and handle security\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains lead and plug\u003c\/td\u003e\n\u003ctd\u003eInspect for damage and secure stowage\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and electrical safety test\u003c\/td\u003e\n\u003ctd\u003eEngineer service and vacuum performance check\u003c\/td\u003e\n\u003ctd\u003ePer local schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe above is general guidance. The manufacturer instructions for use and the operating organisation's decontamination and maintenance policy take precedence. A unit that will not reach its expected vacuum, or that has drawn fluid past the filter, should be taken out of service until it has been inspected.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Laerdal","offers":[{"title":"Default Title","offer_id":58835782992197,"sku":"ESC3888D","price":449.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/IMG-1430.jpg?v=1786467397","url":"https:\/\/selfimed.com\/he\/products\/suction-pump-eschmann-vpx35-four-canisters","provider":"SelfiMed UK","version":"1.0","type":"link"}