{"product_id":"examination-light-daray-x200-led-flexible","title":"Daray X200 LED Flexible Medical Examination Light","description":"\u003cstyle\u003e\n.pw{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;color:#212529;line-height:1.65;font-size:16px;max-width:1000px}\n.pw h2{font-size:26px;line-height:1.3;font-weight:700;color:#1b4f72;margin:0 0 18px}\n.pw h3{font-size:20px;font-weight:700;color:#1b4f72;margin:32px 0 14px}\n.pw p{margin:0 0 16px}\n.pw ul{margin:0 0 16px;padding-left:22px}\n.pw li{margin:0 0 8px}\n.pw-intro{background:#eaf2f8;border-left:5px solid #1b4f72;padding:18px 20px;margin:0 0 26px;border-radius:4px}\n.pw-intro p:last-child{margin-bottom:0}\n.pw-table{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px;table-layout:fixed}\n.pw-table th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700;font-size:15px;white-space:nowrap}\n.pw-table th:nth-child(1),.pw-table td:nth-child(1){width:26%}\n.pw-table th:nth-child(3),.pw-table td:nth-child(3){width:132px}\n.pw-table.pw-excluded th{background:#6c757d}\n.pw-table td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top;word-wrap:break-word;overflow-wrap:break-word}\n.pw-table tr:nth-child(even) td{background:#f8f9fa}\n.pw-badge{display:inline-block;padding:3px 9px;border-radius:3px;font-size:12px;font-weight:700;letter-spacing:.3px;white-space:nowrap}\n.pw-new{background:#d4edda;color:#155724}\n.pw-used{background:#fff3cd;color:#856404}\n.pw-sold{background:#f8d7da;color:#721c24}\n.pw-addon{background:#e2d9f3;color:#4a1d96}\n.pw-box{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 14px}\n.pw-box strong{color:#1b4f72}\n.pw-specs{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-specs th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-specs td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-specs td:first-child{font-weight:600;width:34%;background:#f8f9fa}\n.pw-note{background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-note strong{color:#856404}\n.pw-note p:last-child,.pw-note ul:last-child{margin-bottom:0}\n.pw-alert{background:#eaf2f8;border-left:5px solid #1b4f72;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-alert strong{color:#1b4f72}\n.pw-alert p:last-child,.pw-alert ul:last-child{margin-bottom:0}\n.pw-schedule{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-schedule th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-schedule td{border:1px solid #dee2e6;padding:11px 14px}\n.pw-schedule tr:nth-child(even) td{background:#f8f9fa}\n.pw-media{margin:0 0 26px;text-align:center}\n.pw-media img{max-width:100%;height:auto;border:1px solid #dee2e6;border-radius:5px}\n.pw .pw-docs{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 26px;list-style:none}\n.pw .pw-docs li{background:#fff;border:1px solid #dee2e6;border-radius:4px;margin:0 0 8px;padding:0}\n.pw .pw-docs li:last-child{margin:0}\n.pw .pw-docs a{display:flex;align-items:center;gap:10px;padding:11px 14px;text-decoration:none;color:#1b4f72;font-weight:600;font-size:15px;line-height:1.35}\n.pw .pw-docs a:hover{text-decoration:underline}\n.pw .pw-docs svg{flex:0 0 20px}\n.pw-video-wrap{position:relative;padding-bottom:56.25%;height:0;margin:0 0 26px}\n.pw-video-wrap iframe{position:absolute;top:0;left:0;width:100%;height:100%;border:0;border-radius:5px}\n@media(max-width:600px){.pw h2{font-size:22px}.pw-table,.pw-specs,.pw-schedule{font-size:13px}.pw-specs td:first-child{width:42%}.pw-table th,.pw-table td{padding:9px 8px}.pw-table th:nth-child(1),.pw-table td:nth-child(1){width:30%}.pw-table th:nth-child(3),.pw-table td:nth-child(3){width:104px}.pw-badge{font-size:11px;padding:2px 6px}}\n\u003c\/style\u003e\n\u003cdiv class=\"pw\"\u003e\n\u003ch2\u003eDaray X200 LED Flexible Arm Medical Examination Light, Pre-Owned\u003c\/h2\u003e\n\u003cdiv class=\"pw-intro\"\u003e\n\u003cp\u003eThe Daray X200 is a general examination light for consultation and diagnosis, built around a three LED head on a flexible gooseneck with a pivot base. It gives 32,000 lux at half a metre with a colour rendering index of 95, which is what makes skin tones read naturally rather than washed out or yellowed.\u003c\/p\u003e\n\u003cp\u003eThis unit is pre-owned. The X200 head is common to every mount in the range, and the mount supplied with this particular light is confirmed before dispatch, since it decides where the light can be fitted.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eChecked before dispatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowered on from its supply and the light run through its full intensity range.\u003c\/li\u003e\n\u003cli\u003eGooseneck flexed and the head rotated to confirm it holds position without drooping.\u003c\/li\u003e\n\u003cli\u003ePivot base, mount fitting, lead and plug-top supply inspected for damage.\u003c\/li\u003e\n\u003cli\u003eHead, arm and base cleaned.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are in-house workshop checks. Damaged or non-working items are not dispatched. No engineer service or electrical safety certificate is included. Electrical safety testing and ongoing maintenance under PUWER 1998 remain with the organisation operating the equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eBefore it is fitted and used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis is an examination light for consultation and diagnosis. It is not an operating theatre light and is not a substitute for a surgical luminaire where a shadowless sterile field is required.\u003c\/li\u003e\n\u003cli\u003eElectrical safety testing is carried out on receipt, as for any pre-owned mains powered device in clinical use.\u003c\/li\u003e\n\u003cli\u003eWall and rail mounting is carried out by a competent person, onto a structure able to carry the light and the leverage of an extended arm. Fixings are selected for the wall construction and are not supplied.\u003c\/li\u003e\n\u003cli\u003eRoute the supply lead so it cannot be snagged by a trolley or a chair, and keep the plug-top supply accessible so the light can be isolated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy colour rendering matters more than brightness\u003c\/h3\u003e\n\u003cp\u003eEvery examination light quotes a lux figure, and lux alone says very little about whether the clinician can see what matters. A bright light with poor colour rendering flattens the differences that clinical examination depends on: the distinction between erythema and normal skin, between a cyanotic lip and a cold one, between healthy granulation tissue and slough in a wound bed. The X200 records a colour rendering index of 95 and an R9 value of 88, R9 being the specific measure of deep red reproduction, which is the part of the spectrum that carries skin, blood and mucosa. That combination is why the light is specified for consultation rooms rather than as a general work lamp.\u003c\/p\u003e\n\u003cp\u003eThe other half of the argument is what the light does not do. The head emits no infrared, so the temperature rise in the light field stays at or below 2 degrees C, which matters when the beam sits over the same area of skin for several minutes during a procedure. The head is fully enclosed and finished with an antimicrobial coating on the painted surfaces, so it can be wiped down between patients without dust collecting in vents. And the LED engine is rated beyond 50,000 hours, so there is no lamp to source and change, which on a halogen light is both a running cost and an interruption.\u003c\/p\u003e\n\u003cp\u003eTwo limits are worth stating. It is a general examination light: intense, well rendered and directional, but not a surgical light and not designed to eliminate shadow across a cavity. And the gooseneck, which is what makes it easy to position by hand, is also what distinguishes the X200 from the spring balanced articulated arm on the X240. A gooseneck is positioned by bending it, so somebody who wants to reposition a light repeatedly across a wide arc through the day may prefer the articulated version.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eColour rendering index of 95 with R9 at 88\u003c\/strong\u003e, reproducing deep reds accurately, which is the part of the spectrum that carries skin tone, blood and mucosa in a clinical examination.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003e32,000 lux at half a metre\u003c\/strong\u003e, falling to 14,000 at three quarters of a metre and 8,000 at one metre, so the working distance can be judged rather than guessed.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eIntensity adjustable from 10 to 100 per cent\u003c\/strong\u003e, so the same light serves a bright procedural field and a gentler setting for an examination that does not need full output.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eNo infrared emission\u003c\/strong\u003e, holding the temperature rise in the light field to 2 degrees C or less, which keeps a long examination comfortable for the patient and the clinician.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFully enclosed head with an antimicrobial coating\u003c\/strong\u003e on the painted finishes, so there are no vents to collect dust and the surface can be wiped between patients.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFlexible gooseneck with a pivot base\u003c\/strong\u003e, positioned by hand and holding where it is put, with 320 degrees of head rotation and a 10 degree beam.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eLED engine rated beyond 50,000 hours\u003c\/strong\u003e, so there is no lamp to source, no bulb change and none of the downtime a failed halogen lamp causes mid-clinic.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003e12 W power consumption\u003c\/strong\u003e, which is where the running cost saving against a halogen equivalent comes from, on a light that may be switched on all day.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eHead interchangeable across the mount range\u003c\/strong\u003e, so a light bought on a desk clamp can later be moved to a wall bracket, a rail clamp or a mobile base by buying the mount alone.\u003c\/div\u003e\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification limited to what is confirmed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerformance figures above are manufacturer data for the X200. They describe the model, not measured output from this individual light.\u003c\/li\u003e\n\u003cli\u003eThe mount supplied with this unit is confirmed before dispatch. The X200 is built in wall, rail clamp, desk clamp, weighted desk stand, fixed desk mount and mobile castor base versions, and the mount decides where it can be fitted.\u003c\/li\u003e\n\u003cli\u003eSerial number, age and hours in service are not published here and are read from the unit on request.\u003c\/li\u003e\n\u003cli\u003eThe X200 uses a flexible gooseneck. The articulated spring balanced arm is the X240, and the two are not the same product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eMount options across the range\u003c\/h3\u003e\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eMount\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eX200LW\u003c\/td\u003e\n\u003ctd\u003eWall bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX200LR\u003c\/td\u003e\n\u003ctd\u003eRail clamp, for a wall mounted medical rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX200LD\u003c\/td\u003e\n\u003ctd\u003eDesk clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX200LDS\u003c\/td\u003e\n\u003ctd\u003eWeighted desk stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX200LFDM\u003c\/td\u003e\n\u003ctd\u003eFixed desk mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX200LM\u003c\/td\u003e\n\u003ctd\u003eMobile base on five castors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXRAIL\u003c\/td\u003e\n\u003ctd\u003eOne metre medical rail, with wall fixings, for the rail clamp version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe light head is common to all of these, so a unit can be moved to a different mount later by buying the mount alone.\u003c\/p\u003e\n\u003ch3\u003eCondition and history\u003c\/h3\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003ePre-owned, previously in clinical use\u003c\/strong\u003e, with cosmetic marks consistent with that use. Photographs form part of the description and show the actual light offered.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eNo service history or electrical safety certificate is supplied.\u003c\/strong\u003e Testing on receipt and ongoing maintenance rest with the organisation operating the equipment.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eGooseneck condition is the thing to look at on a used light.\u003c\/strong\u003e The arm should hold its position without creeping down under the weight of the head. This one was flexed and checked before dispatch.\u003c\/div\u003e\n\u003ch3\u003eRoutine checks and care\u003c\/h3\u003e\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWipe the head, arm and base with an approved disinfectant\u003c\/td\u003e\n\u003ctd\u003eBetween patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck the arm holds position and the head rotates freely\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInspect the lead, plug-top supply and mount fixings\u003c\/td\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety testing\u003c\/td\u003e\n\u003ctd\u003eAnnually, or to local policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eUse cleaning products compatible with the coated finish, and avoid solvents, which damage the surface the antimicrobial coating sits on.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Daray","offers":[{"title":"Default Title","offer_id":59109810733381,"sku":"DAR4075D","price":429.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/x200.webp?v=1789157582","url":"https:\/\/selfimed.com\/hr\/products\/examination-light-daray-x200-led-flexible","provider":"SelfiMed UK","version":"1.0","type":"link"}