{"product_id":"mds-lf-8l-steam-sterilizer","title":"MDS LF-8L Steam Sterilizer","description":"\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eMDS LF-8L Class B Steam Sterilizer Autoclave\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe MDS LF-8L is a compact Class B bench-top steam autoclave designed for the sterilisation of wrapped and unwrapped instruments in dental, podiatry, chiropody, tattoo and piercing, beauty and veterinary settings. Class B certification means it is capable of processing all load types including solid, hollow and porous instruments in both wrapped and unwrapped configurations, in compliance with BS EN 13060. An auto-run function initiates the full sterilisation cycle with minimal user input, and adjustable sterilisation time allows the cycle to be configured for different load types.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eA quick cycle and temperature-holding function between runs maximise throughput during busy clinical sessions. B\u0026amp;D and Helix test cycles verify sterilisation performance. An LCD display with built-in printer provides a permanent cycle record for compliance and audit purposes. At 8 litres capacity, the LF-8L is the smallest model in the MDS range and is well suited to low to medium-volume clinical and professional environments. Compliant with MDD 93\/42\/EEC, BS EN 13060, HTM 01-05 and pressure equipment directive 97\/23\/EC.\u003c\/p\u003e\n\u003ch3 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eClass B autoclave\u003c\/strong\u003e - processes all load types including solid, hollow and porous instruments, wrapped and unwrapped; BS EN 13060 compliant\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eAuto-run function\u003c\/strong\u003e - initiates and completes the full sterilisation cycle automatically with minimal user input\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eAdjustable sterilisation time\u003c\/strong\u003e - configurable cycle timing to suit different load types and instrument materials\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eQuick cycle\u003c\/strong\u003e - fast turnaround for busy clinical sessions\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMaintains temperature between cycles\u003c\/strong\u003e - reduces waiting time between consecutive runs; improves throughput\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eB\u0026amp;D test and Helix test cycles\u003c\/strong\u003e - verifies steam penetration and sterilisation performance; meets HTM 01-05 requirements\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eLCD display\u003c\/strong\u003e - clear cycle status and programme information throughout the run\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBuilt-in thermal printer\u003c\/strong\u003e - generates a permanent printed cycle record for compliance and audit documentation\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMechanical and electrical door lock\u003c\/strong\u003e - dual locking system prevents door opening during pressurised cycle\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eSafety functions\u003c\/strong\u003e - overheat, overpressure and low water level protection\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMulti-language interface\u003c\/strong\u003e - suitable for international clinical use\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCompact bench-top footprint\u003c\/strong\u003e - smallest model in the MDS range; suited to low to medium-volume environments\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eSterilises wrapped and unwrapped instruments\u003c\/strong\u003e - full Class B load range in a single compact unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMDS Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eLF-8L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAutoclave class\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eChamber capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e8 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eChamber dimensions (internal)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e320 mm deep x 170 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eTray size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e130 x 255 mm (W x L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSterilisation temperature range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e105°C to 134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMax working pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e0.21 to 0.23 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003e1.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eChamber material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDoor lock\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMechanical and electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOutput\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBuilt-in thermal printer and SD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eStandards compliance\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBS EN 13060, HTM 01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCertification\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eCE 0123, ISO 13485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eRegulatory compliance\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eMDD 93\/42\/EEC, Pressure Equipment Directive 97\/23\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cblockquote class=\"ml-2 border-l-4 border-border-300\/10 pl-4 text-text-300\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e Annual validation and PSSR 2000 inspection are recommended before and during clinical use. The MDS LF-8L requires distilled or demineralised water only. Use of tap water will void performance and may damage the chamber.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"W\u0026H Lisa","offers":[{"title":"Default Title","offer_id":58088679964997,"sku":"MDA2309201","price":599.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/mds-medical-12l-b-type-vacuum-autoclave_480x_ce9aec77-259a-405f-83d2-48804ef109d9.jpg?v=1781595046","url":"https:\/\/selfimed.com\/hr\/products\/mds-lf-8l-steam-sterilizer","provider":"SelfiMed UK","version":"1.0","type":"link"}