{"product_id":"compatible-nellcor-ds-100a-spo2-reusable-paediatric","title":"Compatible Nellcor DS‑100A SpO₂ Reusable Paediatric Finger Clip 3.2 ft 9 Pin- Next Day delivery","description":"\u003ch2 data-start=\"398\" data-end=\"522\"\u003e\u003cstrong data-start=\"401\" data-end=\"522\"\u003ePaediatric Finger Clip: Compatible Nellcor DS-100A Reusable Paediatric Finger Clip Sensor – 3.2 ft 9-Pin OxiMax Cable\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"524\" data-end=\"609\"\u003e\u003cstrong data-start=\"528\" data-end=\"609\"\u003eReliable Paediatric Finger Clip Sensor for Accurate SpO₂ and Pulse Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"611\" data-end=\"1003\"\u003eThe \u003cstrong data-start=\"615\" data-end=\"669\"\u003ePaediatric Finger Clip: Compatible Nellcor DS-100A\u003c\/strong\u003e is a high-quality reusable sensor designed for accurate oxygen saturation (SpO₂) and pulse monitoring in children weighing 15–40 kg. Featuring a \u003cstrong data-start=\"815\" data-end=\"841\"\u003e9-pin OxiMax connector\u003c\/strong\u003e and a \u003cstrong data-start=\"848\" data-end=\"867\"\u003e3.2 ft (0.95 m)\u003c\/strong\u003e TPU-jacketed cable, this \u003cstrong data-start=\"893\" data-end=\"926\"\u003epaediatric finger clip sensor\u003c\/strong\u003e offers flexibility, durability, and precise readings in clinical settings.\u003c\/p\u003e\n\u003cp data-start=\"1005\" data-end=\"1380\"\u003eBuilt for compatibility with \u003cstrong data-start=\"1034\" data-end=\"1061\"\u003eNellcor OxiMax monitors\u003c\/strong\u003e and systems from GE, Philips, Welch Allyn, CASMed, and others, the \u003cstrong data-start=\"1129\" data-end=\"1166\"\u003eCompatible Nellcor DS-100A Sensor\u003c\/strong\u003e ensures plug-and-play performance without calibration. Its ergonomic clip design is optimised for smaller fingers, maintaining stable contact for consistent SpO₂ accuracy across movement and varied environments.\u003c\/p\u003e\n\u003cp data-start=\"1382\" data-end=\"1620\"\u003eTested to international standards (\u003cstrong data-start=\"1417\" data-end=\"1439\"\u003eFDA, CE, ISO, RoHS\u003c\/strong\u003e), this reusable \u003cstrong data-start=\"1456\" data-end=\"1482\"\u003epaediatric finger clip\u003c\/strong\u003e provides dependable monitoring for hospitals, paediatric wards, and home-care applications where reliability and comfort are essential.\u003c\/p\u003e\n\u003chr data-start=\"1622\" data-end=\"1625\"\u003e\n\u003ch3 data-start=\"1627\" data-end=\"1658\"\u003e\u003cstrong data-start=\"1631\" data-end=\"1658\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1660\" data-end=\"2173\"\u003e\n\u003cli data-start=\"1660\" data-end=\"1749\"\u003e\n\u003cp data-start=\"1662\" data-end=\"1749\"\u003e\u003cstrong data-start=\"1662\" data-end=\"1695\"\u003e3.2 ft (0.95 m) Cable Length:\u003c\/strong\u003e Flexible design for bedside or portable monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1750\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1752\" data-end=\"1835\"\u003e\u003cstrong data-start=\"1752\" data-end=\"1779\"\u003ePaediatric Clip Design:\u003c\/strong\u003e Optimised for smaller digits (15–40 kg weight range).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1949\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1949\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1865\"\u003e9-Pin OxiMax Connector:\u003c\/strong\u003e Fully compatible with Nellcor N-595, N-600, GE, Philips, and Welch Allyn systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1950\" data-end=\"2019\"\u003e\n\u003cp data-start=\"1952\" data-end=\"2019\"\u003e\u003cstrong data-start=\"1952\" data-end=\"1974\"\u003eDurable TPU Cable:\u003c\/strong\u003e 4 mm diameter, resistant to clinical wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2020\" data-end=\"2093\"\u003e\n\u003cp data-start=\"2022\" data-end=\"2093\"\u003e\u003cstrong data-start=\"2022\" data-end=\"2040\"\u003eHigh Accuracy:\u003c\/strong\u003e SpO₂ ± 1–3 % across 50–100 % range; Pulse ± 2 bpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2094\" data-end=\"2173\"\u003e\n\u003cp data-start=\"2096\" data-end=\"2173\"\u003e\u003cstrong data-start=\"2096\" data-end=\"2115\"\u003eCertified Safe:\u003c\/strong\u003e FDA, CE, ISO 80601-2-61, ISO 10993, and RoHS compliant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2175\" data-end=\"2178\"\u003e\n\u003ch3 data-start=\"2180\" data-end=\"2212\"\u003e\u003cstrong data-start=\"2184\" data-end=\"2212\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2214\" data-end=\"2780\"\u003e\n\u003cthead data-start=\"2214\" data-end=\"2251\"\u003e\n\u003ctr data-start=\"2214\" data-end=\"2251\"\u003e\n\u003cth data-start=\"2214\" data-end=\"2230\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2216\" data-end=\"2229\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2230\" data-end=\"2251\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2232\" data-end=\"2249\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2290\" data-end=\"2780\"\u003e\n\u003ctr data-start=\"2290\" data-end=\"2320\"\u003e\n\u003ctd data-start=\"2290\" data-end=\"2298\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2298\" data-end=\"2320\" data-col-size=\"md\"\u003eDS-100A Paediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2321\" data-end=\"2355\"\u003e\n\u003ctd data-start=\"2321\" data-end=\"2336\" data-col-size=\"sm\"\u003eCable Length\u003c\/td\u003e\n\u003ctd data-start=\"2336\" data-end=\"2355\" data-col-size=\"md\"\u003e3.2 ft \/ 0.95 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2356\" data-end=\"2397\"\u003e\n\u003ctd data-start=\"2356\" data-end=\"2368\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2368\" data-end=\"2397\"\u003e9-Pin Male D-Sub (OxiMax)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2398\" data-end=\"2444\"\u003e\n\u003ctd data-start=\"2398\" data-end=\"2415\" data-col-size=\"sm\"\u003eCable Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2415\" data-end=\"2444\"\u003eTPU jacket, 4 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2445\" data-end=\"2487\"\u003e\n\u003ctd data-start=\"2445\" data-end=\"2462\" data-col-size=\"sm\"\u003ePatient Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2462\" data-end=\"2487\"\u003e15–40 kg (paediatric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2488\" data-end=\"2558\"\u003e\n\u003ctd data-start=\"2488\" data-end=\"2504\" data-col-size=\"sm\"\u003eSpO₂ Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2504\" data-end=\"2558\"\u003e± 1 % (85–100 %), ± 2 % (70–84 %), ± 3 % (50–69 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2559\" data-end=\"2587\"\u003e\n\u003ctd data-start=\"2559\" data-end=\"2576\" data-col-size=\"sm\"\u003ePulse Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2576\" data-end=\"2587\"\u003e± 2 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2588\" data-end=\"2649\"\u003e\n\u003ctd data-start=\"2588\" data-end=\"2614\" data-col-size=\"sm\"\u003eOperating Temp\/Humidity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2614\" data-end=\"2649\"\u003e32–104 °F (0–40 °C) \/ 0–80 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2650\" data-end=\"2711\"\u003e\n\u003ctd data-start=\"2650\" data-end=\"2667\" data-col-size=\"sm\"\u003eCertifications\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2667\" data-end=\"2711\"\u003eFDA, CE, ISO 80601-2-61, ISO 10993, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2712\" data-end=\"2780\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2728\" data-col-size=\"sm\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2728\" data-end=\"2780\"\u003eNellcor OxiMax, GE, Philips, Welch Allyn, CASMed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2782\" data-end=\"2785\"\u003e\n\u003ch3 data-start=\"2787\" data-end=\"2804\"\u003e\u003cstrong data-start=\"2791\" data-end=\"2804\"\u003eIdeal For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2806\" data-end=\"2962\"\u003e\n\u003cli data-start=\"2806\" data-end=\"2846\"\u003e\n\u003cp data-start=\"2808\" data-end=\"2846\"\u003ePaediatric SpO₂ and pulse monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2847\" data-end=\"2881\"\u003e\n\u003cp data-start=\"2849\" data-end=\"2881\"\u003eHospitals and paediatric wards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2882\" data-end=\"2916\"\u003e\n\u003cp data-start=\"2884\" data-end=\"2916\"\u003eClinics and outpatient centres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2917\" data-end=\"2962\"\u003e\n\u003cp data-start=\"2919\" data-end=\"2962\"\u003eHome-care and long-term oxygen monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nellcor","offers":[{"title":"Default Title","offer_id":54995622461765,"sku":"NEV152101","price":59.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Nellcor_DS_100A_paediatric_finger_clip_sensor_with_3.2_ft_cabl.webp?v=1767164244","url":"https:\/\/selfimed.com\/products\/compatible-nellcor-ds-100a-spo2-reusable-paediatric","provider":"SelfiMed UK","version":"1.0","type":"link"}