{"product_id":"mindray-rm-module","title":"Mindray RM Module","description":"\u003c!-- ═══════════════════════════════════ SECTION 1 : DESCRIPTION, REFERENCES, FEATURES, NOTICES ═══════════════════════════════════ --\u003e\n\n\u003ch2\u003eMindray RM Respiratory Mechanics Module, Part 6800-30-50488, Pre-owned\u003c\/h2\u003e\n\n\u003cp\u003eThe RM module is Mindray's respiratory mechanics parameter module, part number 6800-30-50488, built on Artema technology. It slots into the module rack of a Mindray modular monitor and adds respiratory mechanics monitoring to a bedside that already has the usual haemodynamic parameters, so the ventilated patient can be assessed from the monitor rather than only from the ventilator screen.\u003c\/p\u003e\n\n\u003cp\u003eRespiratory mechanics is the measurement of the pressures, flows and volumes at the airway, and of what those figures say about the lung and about the machine breathing for it. It is the difference between knowing that a ventilator is delivering a set tidal volume and knowing what pressure it is taking to deliver it. In theatre and in intensive care that distinction is what shows a tube kinking, a bronchospasm developing, a circuit leak or a lung becoming stiffer, often before any other parameter on the monitor moves.\u003c\/p\u003e\n\n\u003cp\u003eMindray fit this module to the DPM6 and DPM7, and to the BeneView T5, T6, T8 and T9. It is a parameter module, not a standalone device: it has no screen and no controls of its own, and it does nothing until it is seated in a host monitor that recognises it. That is worth being plain about, because a module bought for a monitor with no vacant slot, or for a monitor outside that list, cannot be used.\u003c\/p\u003e\n\n\u003cp\u003eBuying the module separately is the normal route for a department that already owns the monitors. A modular platform is designed to be extended, so adding respiratory mechanics to an existing BeneView costs the price of a module rather than the price of a monitor, and the module moves between beds as the case mix changes. Elarix Medical confirms the module is read by a monitor before dispatch, and states the parameters it displays in writing.\u003c\/p\u003e\n\n\u003ch3\u003eReferences\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6800-30-50488\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMindray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM respiratory mechanics module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArtema\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost monitors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPM6, DPM7, BeneView T5, T6, T8 and T9\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug in parameter module, not standalone\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAdds respiratory mechanics monitoring to a Mindray modular bedside that already carries the haemodynamic parameters.\u003c\/li\u003e\n  \u003cli\u003eBrings the ventilated patient's airway pressures, flows and volumes onto the patient monitor rather than leaving them on the ventilator screen alone.\u003c\/li\u003e\n  \u003cli\u003eBuilt on Artema technology, as specified by Mindray.\u003c\/li\u003e\n  \u003cli\u003eFits the DPM6 and DPM7, and the BeneView T5, T6, T8 and T9.\u003c\/li\u003e\n  \u003cli\u003eHot pluggable module format, so it moves between beds as the case mix changes.\u003c\/li\u003e\n  \u003cli\u003eExtends an existing monitor for the price of a module rather than the price of a new bedside.\u003c\/li\u003e\n  \u003cli\u003eConfirmed to be read by a host monitor before dispatch, with the displayed parameters stated in writing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px;\"\u003e\n\u003cp\u003e\u003cstrong style=\"color:#856404;\"\u003ePoints to note before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eA flow sensor is needed and is not included.\u003c\/strong\u003e Respiratory mechanics is measured at the patient airway, so the module works through a flow or spirometry sensor placed at the Y piece, with its sensor cable. Neither is part of this sale. Elarix Medical confirms in writing what hardware is supplied with the module and what has to be ordered alongside it.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHost monitor required.\u003c\/strong\u003e This is a parameter module with no screen and no controls. It needs a vacant module slot in a DPM6, DPM7, BeneView T5, T6, T8 or T9. It cannot be used with a monitor outside that list or with another make of monitor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCheck the slot and the configuration.\u003c\/strong\u003e Send the monitor model and its current module set, and Elarix Medical will confirm the fit before dispatch rather than leaving it to be discovered on the ward.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-owned condition.\u003c\/strong\u003e Marks to the case consistent with service use. To be decontaminated to local policy, electrically safety tested and function checked in the host monitor before clinical use. Elarix Medical will photograph the actual module on request.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClinical responsibility.\u003c\/strong\u003e Respiratory mechanics figures inform ventilation decisions but do not make them. Interpretation and any change to ventilator settings remain matters for the clinical team.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- ═══════════════════════════════════ SECTION 2 : TECHNICAL SPECIFICATION ═══════════════════════════════════ --\u003e\n\n\u003ch2\u003eTechnical specification\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMindray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM respiratory mechanics module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6800-30-50488\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug in parameter module for a modular patient monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRespiratory mechanics at the patient airway\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArtema, as specified by Mindray\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameters displayed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed from the unit before dispatch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible monitors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPM6, DPM7, BeneView T5, BeneView T6, BeneView T8, BeneView T9\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandalone operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo, requires a host monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay and controls on the module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom the host monitor module rack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirway sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow or spirometry sensor at the patient Y piece, not included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCleaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface decontamination to local policy, no immersion\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommissioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical safety test and function check in the host monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c!-- ═══════════════════════════════════ SECTION 3 : WHAT IS INCLUDED AND WHAT IS NOT INCLUDED ═══════════════════════════════════ --\u003e\n\n\u003ch2\u003eWhat is included\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMindray RM respiratory mechanics module, part 6800-30-50488, pre-owned\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat is not included\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlow or spirometry sensor for the patient Y piece\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSensor cable\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eHost patient monitor\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModule rack or satellite module housing\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOther parameter modules\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBreathing circuit and Y piece\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePrinted operator or service manual\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDecontamination certificate\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectrical safety testing, function check and commissioning\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mindray","offers":[{"title":"VAT Excluded","offer_id":59719960297797,"sku":"RMC68003","price":199.99,"currency_code":"GBP","in_stock":true},{"title":"VAT Included","offer_id":59719960330565,"sku":"RMC68003","price":199.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Mindray_RM_Module_Selfimed_UK.jpg?v=1791986207","url":"https:\/\/selfimed.com\/products\/mindray-rm-module","provider":"SelfiMed UK","version":"1.0","type":"link"}