{"product_id":"erbe-icc-80-electrosurgical-diathermy-unit-with-dual-footswitch","title":"ERBE ICC 80 Electrosurgical \/ Diathermy Unit with Dual Footswitch","description":"\u003c!-- ═══════════════════════════════════ SECTION 1 : DESCRIPTION, REFERENCES, FEATURES, NOTICES ═══════════════════════════════════ --\u003e\n\u003ch2\u003eERBE ICC 80 Electrosurgical Diathermy Unit with Dual Footswitch, Pre-owned\u003c\/h2\u003e\n\u003cp\u003eThe ERBE ICC 80 is a high frequency electrosurgical generator delivering up to 80 W of cutting and 50 W of coagulation at a rated frequency of 350 kHz, with two cutting effects and three coagulation modes, supplied here with a dual pedal footswitch. It is a compact bench generator at 275 by 105 by 255 mm and 2.8 kg, built for monopolar and bipolar work in a treatment room, a minor operations suite, a dermatology or gynaecology clinic, or an endoscopy list.\u003c\/p\u003e\n\u003cp\u003eThe two cutting effects are the part of the specification worth reading closely, because they are not two power settings but two different waveforms. Cut Effect 1 is an unmodulated sine wave with a crest factor of 2 and a peak voltage of 500 V. A continuous waveform at that crest factor sustains the cutting arc with the least peak voltage for the power delivered, which is the setting for a clean incision with minimal lateral thermal spread. Cut Effect 2 is pulse modulated to a crest factor of 4 at 800 V peak. The higher peak voltage and the gaps between pulses mean that each burst cuts and the intervals coagulate, so the incision closes small vessels as it goes. Both run from 1 to 80 W in 1 W steps against a 500 ohm load, with power limitation held to plus or minus 5 per cent.\u003c\/p\u003e\n\u003cp\u003eThree coagulation modes cover the same ground from different directions. Soft coagulation is unmodulated at 50 W into 200 ohms with a maximum open circuit peak of 190 V, and at that voltage no arc forms, so the mode coagulates by direct contact without carbonising tissue or welding the electrode to it. Forced coagulation is pulse modulated at 50 W into 500 ohms with a peak of 900 V, which does arc, giving faster and deeper coagulation at the cost of surface carbonisation. Bipolar coagulation runs at 50 W into 200 ohms at 190 V peak, with the current confined between the two tips of the forceps so that no neutral electrode sits in the circuit at all.\u003c\/p\u003e\n\u003cp\u003eThe dual footswitch is not an accessory on this generator but part of how it is operated. ERBE specify cutting and both monopolar coagulation modes as activated by either a handpiece key or a pedal, and bipolar coagulation as activated by pedal only, so a unit used for bipolar work needs the footswitch present. The high frequency output is a floating circuit referenced to the neutral electrode rather than to earth, and the unit carries a potential equalisation terminal on the rear, is protection class I to EN 60601-1, and has a type CF applied part to IEC 601-1.\u003c\/p\u003e\n\u003ch3\u003eReferences\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eERBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICC 80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh frequency electrosurgical generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum cutting power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 W at 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum coagulation power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCut Effect 1, Cut Effect 2, soft coagulation, forced coagulation, bipolar coagulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFootswitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual pedal, supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo cutting waveforms rather than two power levels: unmodulated at crest factor 2 for a clean incision, pulse modulated at crest factor 4 for a cut that coagulates as it goes.\u003c\/li\u003e\n\u003cli\u003eCutting adjustable from 1 to 80 W in 1 W steps.\u003c\/li\u003e\n\u003cli\u003eCoagulation adjustable from 1 to 50 W.\u003c\/li\u003e\n\u003cli\u003eSoft coagulation at a maximum open circuit peak of 190 V, below the voltage at which an arc forms, so it coagulates on contact without carbonising.\u003c\/li\u003e\n\u003cli\u003eForced coagulation at 900 V peak for faster and deeper haemostasis.\u003c\/li\u003e\n\u003cli\u003eBipolar coagulation with the current confined between the forceps tips and no neutral electrode in the circuit.\u003c\/li\u003e\n\u003cli\u003ePower limitation held to plus or minus 5 per cent.\u003c\/li\u003e\n\u003cli\u003eFloating high frequency output referenced to the neutral electrode rather than to earth.\u003c\/li\u003e\n\u003cli\u003ePotential equalisation terminal fitted.\u003c\/li\u003e\n\u003cli\u003eProtection class I to EN 60601-1, with a type CF applied part to IEC 601-1.\u003c\/li\u003e\n\u003cli\u003eDual pedal footswitch supplied, which is how bipolar coagulation is activated on this generator.\u003c\/li\u003e\n\u003cli\u003eCompact bench footprint at 275 by 105 by 255 mm and 2.8 kg.\u003c\/li\u003e\n\u003cli\u003eMulti voltage supply, 100, 120, 230 or 240 V alternating current at 50 or 60 Hz.\u003c\/li\u003e\n\u003cli\u003eStandby consumption of 4 W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #fff3cd; border-left: 5px solid #ffc107; padding: 16px 20px; margin: 0 0 22px; border-radius: 4px;\"\u003e\n\u003cp\u003e\u003cstrong style=\"color: #856404;\"\u003ePoints to note before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBipolar coagulation is pedal activated only.\u003c\/strong\u003e ERBE specify cutting and the two monopolar coagulation modes as activated by handpiece key or pedal, and bipolar coagulation as pedal only. A generator intended for bipolar work depends on the footswitch being present and functioning.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ERBE","offers":[{"title":"VAT Exempt","offer_id":60284116500805,"sku":"ERB4184V","price":1477.0,"currency_code":"USD","in_stock":true},{"title":"VAT Included","offer_id":60284116533573,"sku":"ERB4185V","price":1477.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/ERBE_EC-90_surgical_stapler_device.png?v=1795020236","url":"https:\/\/selfimed.com\/ro\/products\/erbe-icc-80-electrosurgical-diathermy-unit-with-dual-footswitch","provider":"SelfiMed UK","version":"1.0","type":"link"}