{"product_id":"hospital-bed-sidhil-innov8-iq-electric-dynamic-mattress","title":"Sidhil Innov8 iQ Electric Hospital Bed with Devilbiss Drive Mattress with Pump (Like New)","description":"\u003cstyle\u003e\n.pw{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;color:#212529;line-height:1.65;font-size:16px;max-width:1000px}\n.pw h2{font-size:26px;line-height:1.3;font-weight:700;color:#1b4f72;margin:0 0 18px}\n.pw h3{font-size:20px;font-weight:700;color:#1b4f72;margin:32px 0 14px}\n.pw p{margin:0 0 16px}\n.pw ul{margin:0 0 16px;padding-left:22px}\n.pw li{margin:0 0 8px}\n.pw-intro{background:#eaf2f8;border-left:5px solid #1b4f72;padding:18px 20px;margin:0 0 26px;border-radius:4px}\n.pw-intro p:last-child{margin-bottom:0}\n.pw-table{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px;table-layout:fixed}\n.pw-table th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700;font-size:15px;white-space:nowrap}\n.pw-table th:nth-child(1),.pw-table td:nth-child(1){width:26%}\n.pw-table th:nth-child(3),.pw-table td:nth-child(3){width:132px}\n.pw-table.pw-excluded th{background:#6c757d}\n.pw-table td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top;word-wrap:break-word;overflow-wrap:break-word}\n.pw-table tr:nth-child(even) td{background:#f8f9fa}\n.pw-badge{display:inline-block;padding:3px 9px;border-radius:3px;font-size:12px;font-weight:700;letter-spacing:.3px;white-space:nowrap}\n.pw-new{background:#d4edda;color:#155724}\n.pw-used{background:#fff3cd;color:#856404}\n.pw-sold{background:#f8d7da;color:#721c24}\n.pw-addon{background:#e2d9f3;color:#4a1d96}\n.pw-box{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 14px}\n.pw-box strong{color:#1b4f72}\n.pw-specs{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-specs th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-specs td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-specs td:first-child{font-weight:600;width:40%;background:#f8f9fa}\n.pw-note{background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-note strong{color:#856404}\n.pw-note p:last-child,.pw-note ul:last-child{margin-bottom:0}\n.pw-alert{background:#eaf2f8;border-left:5px solid #1b4f72;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-alert strong{color:#1b4f72}\n.pw-alert p:last-child,.pw-alert ul:last-child{margin-bottom:0}\n.pw-schedule{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-schedule th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-schedule td{border:1px solid #dee2e6;padding:11px 14px}\n.pw-schedule tr:nth-child(even) td{background:#f8f9fa}\n.pw-media{margin:0 0 26px;text-align:center}\n.pw-media img{max-width:100%;height:auto;border:1px solid #dee2e6;border-radius:5px}\n.pw-docs{list-style:none;margin:0 0 26px;padding:0}\n.pw-docs li{margin:0 0 10px}\n.pw-docs a{display:inline-flex;align-items:center;gap:10px;color:#1b4f72;font-weight:600;text-decoration:none}\n.pw-docs a:hover{text-decoration:underline}\n.pw-docs svg{flex:0 0 auto}\n@media(max-width:600px){.pw h2{font-size:22px}.pw-table,.pw-specs,.pw-schedule{font-size:13px}.pw-specs td:first-child{width:46%}.pw-table th,.pw-table td{padding:9px 8px}.pw-table th:nth-child(1),.pw-table td:nth-child(1){width:30%}.pw-table th:nth-child(3),.pw-table td:nth-child(3){width:104px}.pw-badge{font-size:11px;padding:2px 6px}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"pw\"\u003e\n\n\u003ch2\u003eSidhil Innov8 iQ Electric Profiling Hospital Bed with Dynamic Mattress and Pump, Pre-Owned\u003c\/h2\u003e\n\n\u003cdiv class=\"pw-intro\"\u003e\n\u003cp\u003eThe Sidhil Innov8 iQ is a four section electric profiling ward bed built for acute wards, specialist areas and high dependency use in coronary and high dependency units. It is made in Halifax by the only remaining volume manufacturer of hospital beds in the United Kingdom, which matters on a used bed because spares and service support remain available rather than becoming an obsolete part hunt. The mattress platform runs from 340 mm to 750 mm, so a patient can step off at a low height and a clinician can work at their own. Safe working load is 255 kg with a maximum patient weight of 190 kg. Supplied here with a dynamic alternating pressure mattress and its pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInnov8 iQ bed\u003c\/td\u003e\n\u003ctd\u003eFour section electric profiling ward bed with removable mattress platform panels\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide rails\u003c\/td\u003e\n\u003ctd\u003eCantilever folding side rails as fitted\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed ends\u003c\/td\u003e\n\u003ctd\u003eRemovable head and foot panels\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandsets\u003c\/td\u003e\n\u003ctd\u003eCarer handset and patient handset\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic mattress\u003c\/td\u003e\n\u003ctd\u003eAlternating pressure mattress\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress pump\u003c\/td\u003e\n\u003ctd\u003ePump unit for the dynamic mattress\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains lead\u003c\/td\u003e\n\u003ctd\u003eCoiled mains cable for the bed\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table pw-excluded\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifting pole\u003c\/td\u003e\n\u003ctd\u003ePatient lifting pole, corner socket accessory\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIV pole\u003c\/td\u003e\n\u003ctd\u003eDrip pole, corner socket accessory\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen cylinder carrier\u003c\/td\u003e\n\u003ctd\u003eCorner socket accessory\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraction frames\u003c\/td\u003e\n\u003ctd\u003eBalkan beam and foot end traction\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam mattress\u003c\/td\u003e\n\u003ctd\u003eStatic foam surface where a dynamic mattress is not required\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress extension block\u003c\/td\u003e\n\u003ctd\u003eRequired whenever the platform extension is in use\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and commissioning\u003c\/td\u003e\n\u003ctd\u003eEngineer inspection and electrical safety test\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eChecked before dispatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaned and inspected.\u003c\/li\u003e\n\u003cli\u003ePowered up and function tested through height, backrest, knee break, tilt, auto contour and cardiac chair.\u003c\/li\u003e\n\u003cli\u003eManual and electrical CPR release checked.\u003c\/li\u003e\n\u003cli\u003eSide rails checked for damage, secure fixing and correct latching.\u003c\/li\u003e\n\u003cli\u003eBrake, free and tracking castor modes checked.\u003c\/li\u003e\n\u003cli\u003eMattress pump powered up, mattress inflation and alternating cycle confirmed.\u003c\/li\u003e\n\u003cli\u003eMains lead, plug and both handsets visually inspected for damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service is not included unless this listing states that the unit has been serviced. The manufacturer specifies servicing at least once yearly, and planned maintenance and periodic electrical safety testing remain with the operating organisation once the bed is in service.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eSide rails, mattress fit and entrapment risk\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSide rails only reduce risk when rail, frame and mattress are dimensionally compatible, and the Innov8 iQ has two rail types with different mattress limits. The standard three bar cantilever rail takes a mattress up to 152 mm thick. The high four bar cantilever rail takes up to 279 mm. Fitting a mattress deeper than the rail allows reduces the effective rail height and opens gaps a patient can become trapped in, and an overlay used on top of a foam mattress usually means a thinner foam mattress is needed to keep within the limit. Check the effective rail height above the compressed mattress surface and check every gap against current national guidance on the safe use of bed rails, and reassess whenever the surface changes. The manufacturer states that only Innov8 iQ side rails should be used with this bed, and that these rails are not intended for use with children.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhat the iQ adds over a standard ward bed\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eiQ Contour.\u003c\/strong\u003e When the backrest flattens, the leg section lowers in small steps rather than all at once. That keeps the patient in position on the mattress instead of letting them slide down the bed, which is what generates shear at the sacrum and drives pressure damage. It is the single most useful thing on the bed and it happens without anyone pressing anything extra.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAuto regressing backrest.\u003c\/strong\u003e The deck moves as the backrest rises rather than dragging the patient up the bed, reducing shear and abdominal compression.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCardiac chair.\u003c\/strong\u003e Pressing auto contour and tilt within five seconds of each other profiles the bed into a seated position with foot down tilt, so a patient can sit properly without leaving the bed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTwo handsets with lockout.\u003c\/strong\u003e The carer handset controls everything and can lower the platform to 340 mm. The patient handset is deliberately limited to 420 mm and above, so an unsupervised patient cannot put the bed into the low zone, and any function locked out on the carer handset is locked out on theirs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectrical CPR.\u003c\/strong\u003e One button levels, flattens and lowers the platform, then drives it to maximum height for chest compressions, overriding any locked out functions. Manual CPR handles on both sides drop the backrest faster still.\u003c\/p\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eMattress platform from 340 mm to 750 mm\u003c\/strong\u003e, low enough to reduce injury from falls and high enough for clinicians to work without stooping.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003e255 kg safe working load\u003c\/strong\u003e with a 190 kg maximum patient weight, covering the patient together with the mattress and every accessory carried on the bed.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eElectric backrest, knee break, height and tilt\u003c\/strong\u003e, with head down and foot down tilt to 13 degrees in each direction.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBackrest to 70 degrees\u003c\/strong\u003e, thigh section to 35 degrees and foot section to 21 degrees.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eiQ Contour and auto regression\u003c\/strong\u003e, reducing shear during profiling rather than leaving the patient to slide.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCardiac chair position\u003c\/strong\u003e reached from the handset in one sequence.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBattery backup\u003c\/strong\u003e, so the bed keeps working through a mains interruption.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003e200 mm integral platform extension\u003c\/strong\u003e for taller patients, with a matching leg extension.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFour castor braking with brake, free and tracking modes\u003c\/strong\u003e, so the bed steers straight from the foot end along a corridor.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eRemovable bed ends and mattress platform panels\u003c\/strong\u003e, which is what makes a ward bed realistic to decontaminate properly.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBackrest and tilt angle indicators\u003c\/strong\u003e on both sides, so position is read rather than estimated.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eUnder bed light, linen shelf and catheter bag hooks\u003c\/strong\u003e, plus bed mover mounts at both ends.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eIPX4 rated\u003c\/strong\u003e against splashing water, and dry steam cleanable.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eDynamic mattress and pump included\u003c\/strong\u003e, giving an alternating pressure surface for patients at raised risk of pressure damage.\u003c\/div\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\n\u003ctable class=\"pw-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSidhil, Halifax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eInnov8 iQ general ward bed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eFour section electric profiling hospital bed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe working load\u003c\/td\u003e\n\u003ctd\u003e255 kg, patient plus mattress plus accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum patient weight\u003c\/td\u003e\n\u003ctd\u003e190 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall length\u003c\/td\u003e\n\u003ctd\u003e2280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral length extension\u003c\/td\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall width\u003c\/td\u003e\n\u003ctd\u003e1030 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress platform height\u003c\/td\u003e\n\u003ctd\u003e340 to 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient handset height range\u003c\/td\u003e\n\u003ctd\u003e420 to 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress platform length\u003c\/td\u003e\n\u003ctd\u003e2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress platform width\u003c\/td\u003e\n\u003ctd\u003e880 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder bed clearance\u003c\/td\u003e\n\u003ctd\u003e150 mm with the platform at 420 mm, 80 mm at 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackrest angle\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThigh section angle\u003c\/td\u003e\n\u003ctd\u003e0 to 35 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoot section angle\u003c\/td\u003e\n\u003ctd\u003e0 to 21 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead down tilt\u003c\/td\u003e\n\u003ctd\u003e0 to 13 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoot down tilt\u003c\/td\u003e\n\u003ctd\u003e0 to 13 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress length\u003c\/td\u003e\n\u003ctd\u003e2000 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress width\u003c\/td\u003e\n\u003ctd\u003e864 mm recommended, 880 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress thickness\u003c\/td\u003e\n\u003ctd\u003e152 mm with standard side rails, 279 mm with high side rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress weight\u003c\/td\u003e\n\u003ctd\u003e15 kg maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed weight, frame only\u003c\/td\u003e\n\u003ctd\u003e95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed weight, complete with standard rails\u003c\/td\u003e\n\u003ctd\u003e130 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed weight, complete with high rails\u003c\/td\u003e\n\u003ctd\u003e134 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinen shelf load\u003c\/td\u003e\n\u003ctd\u003e20 kg maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e230 V, plus or minus 10 per cent, 50 to 60 Hz, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003e10 per cent, 2 minutes of continuous use followed by 18 minutes at rest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical classification\u003c\/td\u003e\n\u003ctd\u003eClass 1, Type B applied parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIPX4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60601-1:2005, IEC 60601-2-52:2009, IEC 60601-1-2:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServicing\u003c\/td\u003e\n\u003ctd\u003eAt least once yearly per the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003ePre-owned, powers up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration and mattress details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Innov8 iQ was supplied with a choice of standard or high cantilever side rails, and the rail fitted determines the maximum mattress thickness. The rail type on this unit, and the model of the dynamic mattress and pump supplied with it, are not stated here pending confirmation against the item, and should not be assumed from the description above. Ask before ordering if either is needed, particularly where a specific mattress depth or pump specification is required.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eHoist clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnder bed clearance is 150 mm with the platform at 420 mm and 80 mm at the minimum height of 340 mm. Where a mobile hoist is used with the bed, the manufacturer warns that hoist legs higher than 75 mm risk collision when the bed is operated in the low zone. Check the hoist leg height against the clearance before the bed enters service in a room where hoisting takes place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCondition and history.\u003c\/strong\u003e A pre-owned unit from clinical service, cleaned and inspected, confirmed to power up. Cosmetic marking consistent with previous use should be expected. Ongoing maintenance should follow the operating organisation's planned maintenance schedule and the duties under PUWER 1998. The photographs form part of the description and show the actual condition of the items offered.\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery and access\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis bed measures 2280 mm long and 1030 mm wide and weighs approximately 130 kg complete. Measure every access point on the route before ordering, including external doors, internal doorways, corridor turns, stair widths and lift dimensions.\u003c\/li\u003e\n\u003cli\u003eDimensions given are approximate and should be treated as a guide for access planning rather than exact figures.\u003c\/li\u003e\n\u003cli\u003eDelivery is to ground floor only and the bed is supplied fully assembled. It cannot be carried upstairs or dismantled for delivery.\u003c\/li\u003e\n\u003cli\u003eTwo people should be available to receive the item, with a clear path from the delivery vehicle to the room.\u003c\/li\u003e\n\u003cli\u003eReturn shipping is at the buyer's expense and any delivery fee paid is non-refundable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eRoutine care guidance\u003c\/h3\u003e\n\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide rails\u003c\/td\u003e\n\u003ctd\u003eCheck the release plunger engages, the rail locks upright, and gaps against the mattress in use\u003c\/td\u003e\n\u003ctd\u003eBefore each use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrakes and castors\u003c\/td\u003e\n\u003ctd\u003ePush test with the brake bar down and confirm the bed does not move, then check tracking runs straight\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfiling functions\u003c\/td\u003e\n\u003ctd\u003eCycle height, backrest, knee break, tilt and auto contour through full travel on both handsets\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPR release\u003c\/td\u003e\n\u003ctd\u003eConfirm both manual handles drop the backrest and the electrical CPR function operates\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery backup\u003c\/td\u003e\n\u003ctd\u003eConfirm the bed operates on battery, and keep it on mains between uses\u003c\/td\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMattress and pump\u003c\/td\u003e\n\u003ctd\u003eDecontaminate per local policy, inspect the cover for rips and seam failure, confirm the alternating cycle runs\u003c\/td\u003e\n\u003ctd\u003eBetween patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed extension\u003c\/td\u003e\n\u003ctd\u003eExtend and retract, confirming it locks in both positions and that the mattress extension block is fitted when extended\u003c\/td\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame and fixings\u003c\/td\u003e\n\u003ctd\u003eInspect welds and paint for cracks, and check all nuts, bolts and fasteners are tight\u003c\/td\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngineer service and electrical safety test\u003c\/td\u003e\n\u003ctd\u003eFull service per the manufacturer schedule\u003c\/td\u003e\n\u003ctd\u003eAt least yearly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe above is general guidance. The manufacturer instructions for use and the operating organisation's decontamination and maintenance policy take precedence. The bed should be withdrawn from service if it shows damage or does not perform as intended, until it has been repaired and determined fit for use.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\n\u003cul class=\"pw-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mobilityhire.com\/brochure\/manual\/Innov8%20iQ%20Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg width=\"20\" height=\"24\" viewbox=\"0 0 20 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cpath d=\"M2 0h11l7 7v15a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2V2a2 2 0 0 1 2-2z\" fill=\"#d32f2f\"\u003e\u003c\/path\u003e\u003cpath d=\"M13 0l7 7h-7V0z\" fill=\"#9a0007\"\u003e\u003c\/path\u003e\u003ctext x=\"10\" y=\"18\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"7\" font-weight=\"bold\" fill=\"#fff\" text-anchor=\"middle\"\u003ePDF\u003c\/text\u003e\u003c\/svg\u003eInnov8 iQ instructions for use, full manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mobilityshop.co.uk\/wp\/wp-content\/uploads\/2023\/03\/INNOV8-iQ-Bed-User-Manual-Download.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg width=\"20\" height=\"24\" viewbox=\"0 0 20 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cpath d=\"M2 0h11l7 7v15a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2V2a2 2 0 0 1 2-2z\" fill=\"#d32f2f\"\u003e\u003c\/path\u003e\u003cpath d=\"M13 0l7 7h-7V0z\" fill=\"#9a0007\"\u003e\u003c\/path\u003e\u003ctext x=\"10\" y=\"18\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"7\" font-weight=\"bold\" fill=\"#fff\" text-anchor=\"middle\"\u003ePDF\u003c\/text\u003e\u003c\/svg\u003eInnov8 iQ bed user manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hce-uk.com\/wp-content\/uploads\/2024\/02\/HCE_Sidhil_Innov8_IQ-Quick-Reference-Guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003csvg width=\"20\" height=\"24\" viewbox=\"0 0 20 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cpath d=\"M2 0h11l7 7v15a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2V2a2 2 0 0 1 2-2z\" fill=\"#d32f2f\"\u003e\u003c\/path\u003e\u003cpath d=\"M13 0l7 7h-7V0z\" fill=\"#9a0007\"\u003e\u003c\/path\u003e\u003ctext x=\"10\" y=\"18\" font-family=\"Arial,Helvetica,sans-serif\" font-size=\"7\" font-weight=\"bold\" fill=\"#fff\" text-anchor=\"middle\"\u003ePDF\u003c\/text\u003e\u003c\/svg\u003eInnov8 iQ quick reference guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eAlso in stock.\u003c\/strong\u003e For a lower platform height in a falls prevention setting, see the \u003ca href=\"https:\/\/selfimed.com\/products\/sidhil-innov8-low-electric-hospital-bed\"\u003eSidhil Innov8 Low electric profiling bed\u003c\/a\u003e.\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sidhil","offers":[{"title":"Default Title","offer_id":58987387289925,"sku":"SID4058D","price":1499.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/iq-split-sides-3.webp?v=1787654865","url":"https:\/\/selfimed.com\/ro\/products\/hospital-bed-sidhil-innov8-iq-electric-dynamic-mattress","provider":"SelfiMed UK","version":"1.0","type":"link"}