{"product_id":"heartstart-defibrillator-philips-xl-brand-new-battery","title":"Philips Heartstart XL+ Defibrillator with Brand New Battery","description":"\u003cstyle\u003e\n.pw{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;color:#212529;line-height:1.65;font-size:16px;max-width:1000px}\n.pw h2{font-size:26px;line-height:1.3;font-weight:700;color:#1b4f72;margin:0 0 18px}\n.pw h3{font-size:20px;font-weight:700;color:#1b4f72;margin:32px 0 14px}\n.pw p{margin:0 0 16px}\n.pw ul{margin:0 0 16px;padding-left:22px}\n.pw li{margin:0 0 8px}\n.pw-intro{background:#eaf2f8;border-left:5px solid #1b4f72;padding:18px 20px;margin:0 0 26px;border-radius:4px}\n.pw-intro p:last-child{margin-bottom:0}\n.pw-table{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-table th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700;font-size:15px}\n.pw-table.pw-excluded th{background:#6c757d}\n.pw-table td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-table tr:nth-child(even) td{background:#f8f9fa}\n.pw-badge{display:inline-block;padding:3px 9px;border-radius:3px;font-size:12px;font-weight:700;letter-spacing:.3px;white-space:nowrap}\n.pw-new{background:#d4edda;color:#155724}\n.pw-used{background:#fff3cd;color:#856404}\n.pw-sold{background:#f8d7da;color:#721c24}\n.pw-addon{background:#e2d9f3;color:#4a1d96}\n.pw-box{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 14px}\n.pw-box strong{color:#1b4f72}\n.pw-specs{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-specs th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-specs td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-specs td:first-child{font-weight:600;width:34%;background:#f8f9fa}\n.pw-note{background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-note strong{color:#856404}\n.pw-note p:last-child,.pw-note ul:last-child{margin-bottom:0}\n.pw-alert{background:#eaf2f8;border-left:5px solid #1b4f72;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-alert strong{color:#1b4f72}\n.pw-alert p:last-child,.pw-alert ul:last-child{margin-bottom:0}\n.pw-schedule{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-schedule th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-schedule td{border:1px solid #dee2e6;padding:11px 14px}\n.pw-schedule tr:nth-child(even) td{background:#f8f9fa}\n.pw-media{margin:0 0 26px;text-align:center}\n.pw-media img{max-width:100%;height:auto;border:1px solid #dee2e6;border-radius:5px}\n.pw-docs{list-style:none;margin:0 0 26px;padding:0}\n.pw-docs li{margin:0 0 10px}\n.pw-docs a{display:inline-flex;align-items:center;gap:10px;color:#1b4f72;font-weight:600;text-decoration:none}\n.pw-docs a:hover{text-decoration:underline}\n.pw-docs svg{flex:0 0 auto}\n.pw-video-wrap{position:relative;padding-bottom:56.25%;height:0;overflow:hidden;margin:0 0 26px;border-radius:5px}\n.pw-video-wrap iframe{position:absolute;top:0;left:0;width:100%;height:100%;border:0}\n@media(max-width:600px){.pw h2{font-size:22px}.pw-table,.pw-specs,.pw-schedule{font-size:14px}.pw-specs td:first-child{width:42%}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"pw\"\u003e\n\n\u003ch2\u003ePhilips HeartStart XL+ Defibrillator and Monitor, Model 861290, Pre-Owned with a Brand New Battery\u003c\/h2\u003e\n\n\u003cdiv class=\"pw-intro\"\u003e\n\u003cp\u003eThe Philips HeartStart XL+ is a defibrillator and monitor built to carry a resuscitation from first responder through to advanced life support on one device. It offers four clinical modes: Monitor, Manual Defibrillation, AED and Pacer. A basic life support responder can work in AED mode under voice and text prompts, and the same unit switches to manual defibrillation and pacing when the ALS team arrives, which removes the handover to a second machine at the worst possible moment. Defibrillation uses Philips SMART Biphasic, a low energy biphasic truncated exponential waveform with impedance compensation. Supplied here with a brand new battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeartStart XL+ unit\u003c\/td\u003e\n\u003ctd\u003ePhilips defibrillator and monitor, model 861290\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable lithium-ion battery, brand new\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-new\"\u003eNEW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG cable\u003c\/td\u003e\n\u003ctd\u003ePatient ECG lead set\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cable\u003c\/td\u003e\n\u003ctd\u003eAC mains lead for the device\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest load\u003c\/td\u003e\n\u003ctd\u003eTest plug for shock delivery and operational testing\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table pw-excluded\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultifunction electrode pads\u003c\/td\u003e\n\u003ctd\u003eDefibrillation, pacing and monitoring pads, in-date pads mandatory before use\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaddles\u003c\/td\u003e\n\u003ctd\u003eExternal paddle set\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG electrodes\u003c\/td\u003e\n\u003ctd\u003eSingle-use monitoring electrodes\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter paper\u003c\/td\u003e\n\u003ctd\u003eRecorder paper rolls\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO2, EtCO2 and NBP accessories\u003c\/td\u003e\n\u003ctd\u003eSensors, cuffs and consumables where those options are fitted\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry case or bag\u003c\/td\u003e\n\u003ctd\u003eTransport case\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare battery\u003c\/td\u003e\n\u003ctd\u003eSecond battery for rotation\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and calibration\u003c\/td\u003e\n\u003ctd\u003eEngineer service, output verification and certification\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eMandatory before any use on a person\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFresh, in-date multifunction electrode pads are mandatory. No pads are supplied with this unit, and pads are the delivery path for defibrillation, pacing and pads ECG.\u003c\/li\u003e\n\u003cli\u003eCheck the Ready For Use indicator and run the device's operational test with the supplied test load before the unit is placed on a resuscitation trolley or in a vehicle.\u003c\/li\u003e\n\u003cli\u003eThe device must be used only by clinicians trained on this model. Manual defibrillation, synchronised cardioversion and pacing are advanced interventions.\u003c\/li\u003e\n\u003cli\u003eConfirm the software version and configuration meet the receiving organisation's resuscitation policy, and record the unit on the medical device inventory before it enters service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eChecked before dispatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaned and inspected.\u003c\/li\u003e\n\u003cli\u003ePowered up and function tested, including display, controls, audible prompts and charge cycle.\u003c\/li\u003e\n\u003cli\u003eNew battery fitted and charging confirmed on AC power.\u003c\/li\u003e\n\u003cli\u003eECG cable, power cable and test load checked for damage and secure connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service, output energy verification and certification are not included unless this listing states that the unit has been serviced. Ongoing planned maintenance and periodic electrical safety testing remain with the operating organisation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFour clinical modes\u003c\/strong\u003e, Monitor, Manual Defibrillation, AED and Pacer, so one device covers basic and advanced life support without a mid-resuscitation change of machine.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eSMART Biphasic waveform\u003c\/strong\u003e, a low energy biphasic truncated exponential with waveform parameters adjusted to patient impedance.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eAED mode with voice and text prompts\u003c\/strong\u003e, guiding a basic life support responder through analysis and shock delivery.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eManual defibrillation in three steps\u003c\/strong\u003e, with energy selected by the clinician and synchronised cardioversion available.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eNon-invasive transcutaneous pacing\u003c\/strong\u003e through multifunction electrode pads, in Demand or Fixed modes, where the pacing option is fitted.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eMonitoring of up to three ECG waveforms\u003c\/strong\u003e at a time, acquired through a 3 or 5 lead ECG set or through the pads.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eReady For Use indicator\u003c\/strong\u003e giving a constant status update, which is what makes a defibrillator trustworthy sitting unattended on a trolley.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eAutomated self tests\u003c\/strong\u003e run on a schedule, with critical event and trend data stored in internal memory.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eUSB data export\u003c\/strong\u003e for review in Philips HeartStart Event Review Pro, supporting resuscitation audit and debrief.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eRechargeable lithium-ion battery with AC as a secondary source\u003c\/strong\u003e, charging continuously while plugged in, so the unit is ready whether docked or carried.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBrand new battery fitted\u003c\/strong\u003e, which on a used defibrillator is the single component that most often makes the difference between a working unit and a shelf ornament.\u003c\/div\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\n\u003ctable class=\"pw-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePhilips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHeartStart XL+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003e861290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eDefibrillator and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical modes\u003c\/td\u003e\n\u003ctd\u003eMonitor, Manual Defibrillation, AED, Pacer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSMART Biphasic, biphasic truncated exponential, impedance compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock delivery\u003c\/td\u003e\n\u003ctd\u003eMultifunction electrode pads or paddles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacing\u003c\/td\u003e\n\u003ctd\u003eNon-invasive transcutaneous, Demand and Fixed modes, optional feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG monitoring\u003c\/td\u003e\n\u003ctd\u003eUp to three waveforms, 3 or 5 lead set or pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional monitoring\u003c\/td\u003e\n\u003ctd\u003eSpO2, EtCO2 and NBP available as options, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eRechargeable lithium-ion battery, AC as secondary source with continuous charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadiness\u003c\/td\u003e\n\u003ctd\u003eReady For Use indicator with scheduled automated tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData\u003c\/td\u003e\n\u003ctd\u003eInternal event and trend memory, USB export to Event Review Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery condition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit condition\u003c\/td\u003e\n\u003ctd\u003ePre-owned, good\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eFitted options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePacing, SpO2, EtCO2 and non-invasive blood pressure were optional on the HeartStart XL+ and were not fitted to every unit. Where a particular capability is essential, ask before ordering and the configuration will be confirmed from the device information screen. The unit is offered on the basis of the specification and photographs shown.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCondition and history.\u003c\/strong\u003e A pre-owned unit in good condition, cleaned and inspected, supplied with a new battery. Cosmetic marking consistent with previous clinical use should be expected. Ongoing maintenance should follow the operating organisation's medical device management policy and the duties under PUWER 1998. The photographs form part of the description and show the actual condition of the items offered.\u003c\/div\u003e\n\n\u003ch3\u003eRoutine care guidance\u003c\/h3\u003e\n\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReady For Use indicator\u003c\/td\u003e\n\u003ctd\u003eCheck the indicator and investigate any change in status\u003c\/td\u003e\n\u003ctd\u003eDaily\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePads\u003c\/td\u003e\n\u003ctd\u003eConfirm sealed pads are in date and a spare set is held\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational test\u003c\/td\u003e\n\u003ctd\u003eRun the shock delivery test with the test load per local policy\u003c\/td\u003e\n\u003ctd\u003ePer local schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eKeep on AC between uses, note any fall in run time\u003c\/td\u003e\n\u003ctd\u003eAfter each use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCables and connectors\u003c\/td\u003e\n\u003ctd\u003eInspect the ECG cable, mains lead and pads connector for damage\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter\u003c\/td\u003e\n\u003ctd\u003eCheck paper stock and print quality where the recorder is used\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing and display\u003c\/td\u003e\n\u003ctd\u003eWipe down per local policy, inspect for cracks and fluid ingress\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and output verification\u003c\/td\u003e\n\u003ctd\u003eEngineer service and delivered energy check\u003c\/td\u003e\n\u003ctd\u003ePer local schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe above is general guidance. The manufacturer instructions for use and the operating organisation's resuscitation and medical device policies take precedence. Any unit that fails a self test or an operational check should be taken out of service immediately and replaced on the trolley by a working device.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Philips","offers":[{"title":"With Pacing","offer_id":53926983696709,"sku":"PHD0686W02","price":749.99,"currency_code":"GBP","in_stock":true},{"title":"With No Pacing","offer_id":53926983729477,"sku":"PHD0686W01","price":699.99,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/philips-heartstart-xl-defibrillator-309309.jpg?v=1767157439","url":"https:\/\/selfimed.com\/sr\/products\/heartstart-defibrillator-philips-xl-brand-new-battery","provider":"SelfiMed UK","version":"1.0","type":"link"}