{"product_id":"infant-incubator-draeger-air-shields-isolette-c2000","title":"Draeger Air Shields Isolette C2000 Incubator","description":"\u003cstyle\u003e\n  .product-wrapper {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n    font-size: 1.05rem;\n  }\n\n  .box-intro {\n    background: #eef3ff;\n    border: 1px solid #c7d3ff;\n    padding: 1.5rem;\n    border-radius: 6px;\n    margin-bottom: 2rem;\n  }\n\n  .box-highlight {\n    background: #f5f7fa;\n    border: 1px solid #d5d9e2;\n    padding: 1.3rem;\n    border-radius: 6px;\n    margin-bottom: 1.8rem;\n  }\n\n  .box-specs {\n    background: #f8f9fb;\n    border: 1px solid #cfd4dc;\n    padding: 1.3rem;\n    border-radius: 6px;\n    margin-bottom: 1.8rem;\n  }\n\n  .product-spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 1.05rem;\n  }\n\n  .product-spec-table th,\n  .product-spec-table td {\n    border: 1px solid #bfc5ce;\n    padding: 0.8rem 0.9rem;\n    vertical-align: top;\n  }\n\n  .product-spec-table th {\n    width: 32%;\n    background: #e4e7ec;\n    font-weight: 700;\n  }\n\n  .product-wrapper ul {\n    margin: 0.5rem 0 0.75rem;\n    padding-left: 1.3rem;\n  }\n\n  .product-wrapper li {\n    margin-bottom: 0.5rem;\n  }\n\n  .box-documents {\n    background: #f5f7fa;\n    border: 1px solid #d5d9e2;\n    padding: 1.2rem;\n    border-radius: 6px;\n    margin-top: 1.4rem;\n    margin-bottom: 1.8rem;\n  }\n\n  .pdf-doc-list {\n    list-style: none;\n    padding-left: 0;\n    margin: 0;\n  }\n\n  .pdf-doc-item {\n    background: #ffffff;\n    border: 1px solid #dde3ef;\n    border-radius: 4px;\n    padding: 0.55rem 0.7rem;\n    margin-bottom: 0.5rem;\n    display: flex;\n    align-items: flex-start;\n    gap: 0.55rem;\n  }\n\n  .pdf-doc-item a {\n    text-decoration: none;\n    color: inherit;\n  }\n\n  .pdf-doc-item a:hover {\n    text-decoration: underline;\n  }\n\n  .pdf-icon {\n    width: 18px;\n    height: 18px;\n    display: inline-block;\n  }\n\n  .pdf-icon svg {\n    width: 100%;\n    height: 100%;\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"product-wrapper\"\u003e\n\u003cdiv class=\"Y3BBE\" data-complete=\"true\" data-processed=\"true\" data-hveid=\"CAIQAA\" data-sfc-cp=\"\"\u003e\n\u003cdiv style=\"text-align: start;\" data-processed=\"true\" data-complete=\"true\" data-subtree=\"aimfl\"\u003e\n\u003ch2 data-end=\"182\" data-start=\"136\"\u003eDraeger Air-Shields Isolette C2000 Incubator\u003c\/h2\u003e\n\u003cdiv class=\"box-intro\"\u003e\n\u003cp data-end=\"701\" data-start=\"184\"\u003eThe \u003cstrong data-end=\"201\" data-start=\"188\"\u003eincubator\u003c\/strong\u003e Dräger Air-Shields Isolette C2000 is a high-performance neonatal incubator designed for use in neonatal intensive care units. This incubator provides advanced thermoregulation and a stable, developmentally supportive environment for premature and critically ill infants. The Dräger Air-Shields Isolette C2000 incubator uses a proven PID temperature control algorithm combined with a double-wall canopy and patented dual air-curtain technology to minimise heat loss, even when access panels are open.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"701\" data-start=\"184\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Draeger_Air-Shields_Isolette_C2000_Incubator.png?v=1765547731\" alt=\"Draeger Air-Shields Isolette C2000 Incubator\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"box-highlight\"\u003e\n\u003cp data-end=\"1154\" data-start=\"703\"\u003eDesigned with both infant safety and caregiver ergonomics in mind, this incubator features large oval access doors with quiet-latch mechanisms and full-length hinged side panels for excellent clinical access. External mattress tilt controls allow caregivers to adjust positioning from 0° to 12° without disturbing the infant. With a low internal noise level of under 47 dBA, the incubator supports neurodevelopment while reducing environmental stress.\u003c\/p\u003e\n\u003cp data-end=\"1154\" data-start=\"703\"\u003eThis unit is supplied without the small pocket drawer component visible in the accompanying photographs.\u003c\/p\u003e\n\u003cp data-end=\"1570\" data-start=\"1156\"\u003eThe Isolette C2000 incubator also supports integrated monitoring and documentation through 24-hour trending of air temperature, skin temperature, humidity, oxygen concentration, and heater output. Its modular architecture allows optional configuration with servo-controlled humidity, oxygen control, integrated weighing scales, and X-ray tray systems, making it adaptable to a wide range of NICU care requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"1570\" data-start=\"1156\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Draeger_Air-Shields_Isolette_C2000_Incubator_1.jpg?v=1765547791\" alt=\"Draeger Air-Shields Isolette C2000 Incubator\"\u003e\u003c\/p\u003e\n\u003chr data-end=\"1575\" data-start=\"1572\"\u003e\n\u003ch3 data-end=\"1589\" data-start=\"1577\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv class=\"box-highlight\"\u003e\n\u003cp data-end=\"2168\" data-start=\"1591\"\u003e• Advanced thermoregulation using Dräger PID control algorithm\u003cbr data-end=\"1656\" data-start=\"1653\"\u003e• Double-wall canopy with patented dual air-curtain technology\u003cbr data-end=\"1721\" data-start=\"1718\"\u003e• Quiet-latch oval access doors for reduced heat loss\u003cbr data-end=\"1777\" data-start=\"1774\"\u003e• Large hinged side panels for full infant access\u003cbr data-end=\"1829\" data-start=\"1826\"\u003e• External mattress tilt adjustment from 0° to 12°\u003cbr data-end=\"1882\" data-start=\"1879\"\u003e• Low internal noise level below 47 dBA\u003cbr data-end=\"1924\" data-start=\"1921\"\u003e• 24-hour trending of temperature, humidity, oxygen and heater power\u003cbr data-end=\"1995\" data-start=\"1992\"\u003e• Compact footprint suitable for space-efficient NICU layouts\u003cbr data-end=\"2059\" data-start=\"2056\"\u003e• Optional servo-controlled humidity and oxygen systems\u003cbr data-end=\"2117\" data-start=\"2114\"\u003e• Optional integrated scale and in-bed X-ray tray\u003c\/p\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2173\" data-start=\"2170\"\u003e\n\u003ch3 data-end=\"2203\" data-start=\"2175\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"box-specs\"\u003e\n\u003ctable class=\"product-spec-table\" data-end=\"2817\" data-start=\"2205\"\u003e\n\u003cthead data-end=\"2232\" data-start=\"2205\"\u003e\n\u003ctr data-end=\"2232\" data-start=\"2205\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2221\" data-start=\"2205\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\" data-end=\"2232\" data-start=\"2221\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2817\" data-start=\"2249\"\u003e\n\u003ctr data-end=\"2284\" data-start=\"2249\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2264\" data-start=\"2249\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2284\" data-start=\"2264\"\u003eInfant incubator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2310\" data-start=\"2285\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2300\" data-start=\"2285\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd data-end=\"2310\" data-start=\"2300\" data-col-size=\"lg\"\u003eDräger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2349\" data-start=\"2311\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2319\" data-start=\"2311\"\u003eModel\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2349\" data-start=\"2319\"\u003eAir-Shields Isolette C2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2408\" data-start=\"2350\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2380\" data-start=\"2350\"\u003eDimensions (with VHA stand)\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2408\" data-start=\"2380\"\u003e99 × 67 × 133.4–152.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2440\" data-start=\"2409\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2431\" data-start=\"2409\"\u003eWeight (with stand)\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2440\" data-start=\"2431\"\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2473\" data-start=\"2441\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2457\" data-start=\"2441\"\u003eMattress Size\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2473\" data-start=\"2457\"\u003e40.6 × 81 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2520\" data-start=\"2474\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2503\" data-start=\"2474\"\u003eAir Mode Temperature Range\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2520\" data-start=\"2503\"\u003e20 to 39.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2570\" data-start=\"2521\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2551\" data-start=\"2521\"\u003eSkin Mode Temperature Range\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2570\" data-start=\"2551\"\u003e34.0 to 38.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2620\" data-start=\"2571\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2596\" data-start=\"2571\"\u003eHumidity Control Range\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2620\" data-start=\"2596\"\u003e30–95% RH (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2666\" data-start=\"2621\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2644\" data-start=\"2621\"\u003eOxygen Control Range\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2666\" data-start=\"2644\"\u003e21%–65% (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2693\" data-start=\"2667\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2681\" data-start=\"2667\"\u003eNoise Level\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2693\" data-start=\"2681\"\u003e\u0026lt; 47 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2817\" data-start=\"2694\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2708\" data-start=\"2694\"\u003eAlarm Types\u003c\/th\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2817\" data-start=\"2708\"\u003eAir\/skin temperature, airflow failure, power failure, sensor failure, optional humidity and oxygen alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2822\" data-start=\"2819\"\u003e\n\u003ch3 data-end=\"2843\" data-start=\"2824\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cdiv class=\"box-specs\"\u003e\n\u003cp data-end=\"2905\" data-start=\"2845\"\u003e• Draeger Air-Shields Isolette C2000 Incubator\u003cbr data-end=\"2893\" data-start=\"2890\"\u003e• Mattress\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 1.25rem;\"\u003eHelpful documents\u003c\/h3\u003e\n\u003cdiv class=\"box-documents\"\u003e\n\u003cul class=\"pdf-doc-list\"\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.draeger.com\/Content\/Documents\/Products\/isolette-c2000-with-cabinet-stand-pi-9069067-en-gb.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Isolette C2000 Product Information, en \u003c\/a\u003e \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.draeger.com\/Content\/Documents\/Products\/isolette-c2000-br-9050630-en-master.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Isolette C2000 Brochure, en \u003c\/a\u003e \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.draeger.com\/ifu\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Technical Documentation Service \u003c\/a\u003e \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.draeger.com\/Content\/Documents\/Products\/neonatal-and-pediatric-accessories-ca-9066934-en.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Neonatal and pediatric accessories catalogue, en \u003c\/a\u003e \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.draeger.com\/Content\/Documents\/Products\/accessory-ca-9066485-en-master.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e Accessory Catalogue 2025\/2026, en \u003c\/a\u003e \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Draeger","offers":[{"title":"Default Title","offer_id":56602976878917,"sku":"DRI192401","price":1799.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Draeger_Air_Shields_Isolette_C2000_Incubator_12.png?v=1766652183","url":"https:\/\/selfimed.com\/sv\/products\/infant-incubator-draeger-air-shields-isolette-c2000","provider":"SelfiMed UK","version":"1.0","type":"link"}