{"product_id":"mobile-patient-hoist-arjo-tenor-bariatric-weighing","title":"Arjo Tenor Bariatric Mobile Patient Hoist with Weighing Scale","description":"\u003cstyle\u003e\n.pw{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;color:#212529;line-height:1.65;font-size:16px;max-width:1000px}\n.pw h2{font-size:26px;line-height:1.3;font-weight:700;color:#1b4f72;margin:0 0 18px}\n.pw h3{font-size:20px;font-weight:700;color:#1b4f72;margin:32px 0 14px}\n.pw p{margin:0 0 16px}\n.pw ul{margin:0 0 16px;padding-left:22px}\n.pw li{margin:0 0 8px}\n.pw-intro{background:#eaf2f8;border-left:5px solid #1b4f72;padding:18px 20px;margin:0 0 26px;border-radius:4px}\n.pw-intro p:last-child{margin-bottom:0}\n.pw-table{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-table th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700;font-size:15px}\n.pw-table.pw-excluded th{background:#6c757d}\n.pw-table td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-table tr:nth-child(even) td{background:#f8f9fa}\n.pw-badge{display:inline-block;padding:3px 9px;border-radius:3px;font-size:12px;font-weight:700;letter-spacing:.3px;white-space:nowrap}\n.pw-new{background:#d4edda;color:#155724}\n.pw-used{background:#fff3cd;color:#856404}\n.pw-sold{background:#f8d7da;color:#721c24}\n.pw-addon{background:#e2d9f3;color:#4a1d96}\n.pw-box{background:#f8f9fa;border:1px solid #dee2e6;border-radius:5px;padding:16px 18px;margin:0 0 14px}\n.pw-box strong{color:#1b4f72}\n.pw-specs{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-specs th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-specs td{border:1px solid #dee2e6;padding:11px 14px;vertical-align:top}\n.pw-specs td:first-child{font-weight:600;width:40%;background:#f8f9fa}\n.pw-note{background:#fff3cd;border-left:5px solid #ffc107;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-note strong{color:#856404}\n.pw-note p:last-child,.pw-note ul:last-child{margin-bottom:0}\n.pw-alert{background:#eaf2f8;border-left:5px solid #1b4f72;padding:16px 20px;margin:0 0 22px;border-radius:4px}\n.pw-alert strong{color:#1b4f72}\n.pw-alert p:last-child,.pw-alert ul:last-child{margin-bottom:0}\n.pw-schedule{width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px}\n.pw-schedule th{background:#1b4f72;color:#fff;text-align:left;padding:12px 14px;font-weight:700}\n.pw-schedule td{border:1px solid #dee2e6;padding:11px 14px}\n.pw-schedule tr:nth-child(even) td{background:#f8f9fa}\n.pw-media{margin:0 0 26px;text-align:center}\n.pw-media img{max-width:100%;height:auto;border:1px solid #dee2e6;border-radius:5px}\n.pw-docs{list-style:none;margin:0 0 26px;padding:0}\n.pw-docs li{margin:0 0 10px}\n.pw-docs a{display:inline-flex;align-items:center;gap:10px;color:#1b4f72;font-weight:600;text-decoration:none}\n.pw-docs a:hover{text-decoration:underline}\n.pw-docs svg{flex:0 0 auto}\n.pw-video-wrap{position:relative;padding-bottom:56.25%;height:0;overflow:hidden;margin:0 0 26px;border-radius:5px}\n.pw-video-wrap iframe{position:absolute;top:0;left:0;width:100%;height:100%;border:0}\n@media(max-width:600px){.pw h2{font-size:22px}.pw-table,.pw-specs,.pw-schedule{font-size:14px}.pw-specs td:first-child{width:46%}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"pw\"\u003e\n\n\u003ch2\u003eArjo Tenor Bariatric Mobile Patient Hoist with Integrated Weighing Scale, 320 kg Safe Working Load, Pre-Owned\u003c\/h2\u003e\n\n\u003cdiv class=\"pw-intro\"\u003e\n\u003cp\u003eThe Arjo Tenor is a heavy duty mobile floor lifter built for plus-size and bariatric transfers, with a safe working load of 320 kg. That capacity places it at the top of the mobile hoist range and is the reason services keep one on the ward rather than hiring in when a bariatric admission arrives. The curved jib clears the patient and allows full 360 degree rotation once lifted, and the four point bariatric spreader bar widens the gap between shoulder and leg hooks so the sling distributes load rather than squeezing. This unit carries the integrated suspended weighing scale, so a weight is captured during the transfer instead of becoming a separate procedure that often does not happen at all in bariatric care. Supplied with a pre-owned battery. Sling and charger are sold separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eArjo Tenor hoist\u003c\/td\u003e\n\u003ctd\u003eBariatric mobile floor lifter with curved jib and width-adjustable chassis legs\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated weighing scale\u003c\/td\u003e\n\u003ctd\u003eSuspended scale fitted to the hoist\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFour point bariatric spreader bar\u003c\/td\u003e\n\u003ctd\u003eWide-gap spreader bar for shoulder and leg hooks\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eSealed lead acid 24 V 4 Ah, part number NDA0100-20\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHand control\u003c\/td\u003e\n\u003ctd\u003eHandset for lift and lower\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-used\"\u003eUSED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\n\u003ctable class=\"pw-table pw-excluded\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlings\u003c\/td\u003e\n\u003ctd\u003eSelected by weight, body distribution, height and physical condition\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charger\u003c\/td\u003e\n\u003ctd\u003eCharging unit for the 24 V battery\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-addon\"\u003eADD-ON\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare battery\u003c\/td\u003e\n\u003ctd\u003eSecond pack for rotation between charges\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale verification\u003c\/td\u003e\n\u003ctd\u003eCalibration check of the weighing function against a certified reference\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThorough examination\u003c\/td\u003e\n\u003ctd\u003eSix monthly examination by a competent person under LOLER 1998\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService and inspection\u003c\/td\u003e\n\u003ctd\u003eEngineer service and load testing\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"pw-badge pw-sold\"\u003eSOLD SEPARATELY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eMandatory before any use with a patient\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis is lifting equipment used to lift persons. In Great Britain it requires a thorough examination by a competent person at least every six months under LOLER 1998, with a current report held before the equipment enters service.\u003c\/li\u003e\n\u003cli\u003eNo sling is supplied. Slings must be matched to the individual by weight, body distribution, height and physical condition, and the safe working load printed on the sling label must be checked before every use.\u003c\/li\u003e\n\u003cli\u003eThe lowest safe working load in the complete system governs. A 320 kg hoist used with a 250 kg sling is a 250 kg system, and the spreader bar rating applies in the same way.\u003c\/li\u003e\n\u003cli\u003eSlings must be inspected before every use and withdrawn from service if any fraying, damage or wear is found.\u003c\/li\u003e\n\u003cli\u003eThe Tenor should be serviced and inspected only by suitably qualified personnel approved for this equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003ePre-owned battery, no charger supplied\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe battery is pre-owned. Capacity in any sealed lead acid pack falls with age and cycle count, so the number of lifts available from a full charge cannot be stated for this unit and must be assessed once it is on charge. No charger is supplied, so a charger must be in place before the hoist can be brought into service. Where a bariatric caseload depends on the hoist being available at short notice, a fresh battery and a second pack on rotation are worth budgeting for. The battery is a sealed lead acid 24 V 4 Ah pack, part number NDA0100-20.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeighing scale accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated scale is a measuring function on a pre-owned device and its accuracy has not been verified here. Before any weight from this hoist is used for a clinical decision, particularly weight-based drug dosing, the scale should be checked against a certified reference by a qualified engineer and then verified at the interval set by the operating organisation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"pw-alert\"\u003e\n\u003cp\u003e\u003cstrong\u003eChecked before dispatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaned and inspected.\u003c\/li\u003e\n\u003cli\u003ePowered up and function tested through the full hoisting range, with the hand control and mast panel confirmed.\u003c\/li\u003e\n\u003cli\u003eEmergency lowering override checked.\u003c\/li\u003e\n\u003cli\u003eSpreader bar, hooks, jib and mast checked for damage, distortion and secure fixing.\u003c\/li\u003e\n\u003cli\u003eChassis leg adjustment, castors, brakes and battery discharge indicator checked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service, load test, scale verification and thorough examination are not included unless this listing states that the unit has been serviced. Ongoing inspection and six monthly thorough examination remain with the operating organisation once the equipment is in service.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003e320 kg safe working load\u003c\/strong\u003e, among the highest of any mobile patient hoist, covering the full range of bariatric transfers in acute and long-term care.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eIntegrated suspended weighing scale\u003c\/strong\u003e, capturing a weight during the transfer rather than as a separate procedure, which is often the only practical way to weigh a bariatric patient.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCurved jib\u003c\/strong\u003e maximising lifting clearance and allowing 360 degree rotation with the patient in the lifted position.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eFour point bariatric spreader bar\u003c\/strong\u003e widening the gap between shoulder and leg hooks, distributing weight more evenly and reducing sling squeezing forces.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eWidth-adjustable chassis legs\u003c\/strong\u003e, spreading for stability and closing for access around low-clearance beds, wheelchairs and furniture.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003e1225 mm hoisting range\u003c\/strong\u003e, from a minimum central suspension point height of 800 mm up to 2025 mm with legs spread, covering floor recovery through to a high bed.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eDual controls\u003c\/strong\u003e at the mast panel and on the hand control, so the carer can stay beside the patient throughout the lift.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eErgonomic curved handlebar\u003c\/strong\u003e for turning and manoeuvring a heavy load in a confined ward space.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eEmergency lowering override\u003c\/strong\u003e, returning the patient to a safe seated position if power or the system fails mid-lift.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eBattery discharge indicator\u003c\/strong\u003e at the rear, showing charge status with a warning before the pack runs down.\u003c\/div\u003e\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eIPX4 rated\u003c\/strong\u003e, protected against splashing water from any direction for routine decontamination.\u003c\/div\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\n\u003ctable class=\"pw-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eArjo, formerly ArjoHuntleigh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTenor with weighing scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eBariatric mobile patient hoist, floor lifter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe working load\u003c\/td\u003e\n\u003ctd\u003e320 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoist weight, without battery, with scale\u003c\/td\u003e\n\u003ctd\u003e66.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoisting range\u003c\/td\u003e\n\u003ctd\u003e1225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum central suspension point height\u003c\/td\u003e\n\u003ctd\u003e800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum height at maximum hoisting reach\u003c\/td\u003e\n\u003ctd\u003e1405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum height, legs spread\u003c\/td\u003e\n\u003ctd\u003e2025 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum wall distance at maximum reach, legs spread\u003c\/td\u003e\n\u003ctd\u003e335 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum wall distance at minimum height, legs spread\u003c\/td\u003e\n\u003ctd\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurning radius\u003c\/td\u003e\n\u003ctd\u003e1650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpreader bar\u003c\/td\u003e\n\u003ctd\u003eFour point bariatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighing scale\u003c\/td\u003e\n\u003ctd\u003eSuspended, integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eSealed lead acid, 24 V, 4 Ah, part number NDA0100-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIPX4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical classification\u003c\/td\u003e\n\u003ctd\u003eInternally powered equipment, Type B applied part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN and IEC 60601-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003ePre-owned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"pw-box\"\u003e\n\u003cstrong\u003eCondition and history.\u003c\/strong\u003e A pre-owned unit from clinical service, cleaned and inspected. Cosmetic marking consistent with previous use should be expected. Ongoing maintenance should follow the operating organisation's planned maintenance schedule and the duties under LOLER 1998 and PUWER 1998. The photographs form part of the description and show the actual condition of the item offered.\u003c\/div\u003e\n\n\u003cdiv class=\"pw-note\"\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery and access\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis is a large, heavy item at 66.4 kg with a turning radius of 1650 mm. Measure every access point on the route before ordering, including doorways, corridor turns and lift dimensions, and check the intended room can accommodate the turning circle.\u003c\/li\u003e\n\u003cli\u003eDimensions given are approximate and should be treated as a guide for access planning rather than exact figures.\u003c\/li\u003e\n\u003cli\u003eDelivery is to ground floor only. Two people should be available to receive and move the item.\u003c\/li\u003e\n\u003cli\u003eReturn shipping is at the buyer's expense and any delivery fee paid is non-refundable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eRoutine care guidance\u003c\/h3\u003e\n\n\u003ctable class=\"pw-schedule\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlings\u003c\/td\u003e\n\u003ctd\u003eInspect webbing, stitching, loops and labels, withdraw any sling showing fraying or damage\u003c\/td\u003e\n\u003ctd\u003eBefore each use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpreader bar and hooks\u003c\/td\u003e\n\u003ctd\u003eCheck hooks, latches and attachment points for wear and distortion\u003c\/td\u003e\n\u003ctd\u003eBefore each use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eReturn to charge after use, check the discharge indicator, note any fall in the number of lifts\u003c\/td\u003e\n\u003ctd\u003eAfter each use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrakes and castors\u003c\/td\u003e\n\u003ctd\u003eConfirm the brakes hold, clear hair and debris from the castor spindles\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency lowering\u003c\/td\u003e\n\u003ctd\u003eConfirm the override operates\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMast, jib and chassis\u003c\/td\u003e\n\u003ctd\u003eInspect for cracks, corrosion, loose fasteners and leg adjustment function\u003c\/td\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighing scale\u003c\/td\u003e\n\u003ctd\u003eCheck against a known reference weight per local policy\u003c\/td\u003e\n\u003ctd\u003ePer local schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThorough examination\u003c\/td\u003e\n\u003ctd\u003eFormal examination by a competent person under LOLER 1998\u003c\/td\u003e\n\u003ctd\u003eAt least every six months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe above is general guidance. The manufacturer instructions for use and the operating organisation's moving and handling policy take precedence. Any hoist showing damage or a fault should be taken out of service until it has been inspected and repaired.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Arjo Huntleigh","offers":[{"title":"Without charger","offer_id":58878435623237,"sku":"ARH226101","price":549.99,"currency_code":"GBP","in_stock":true},{"title":"With Charger","offer_id":58878435656005,"sku":"ARH226102","price":699.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Arjo-Tenor-with-Weight-Scale-Badge.webp?v=1780340821","url":"https:\/\/selfimed.com\/tr\/products\/mobile-patient-hoist-arjo-tenor-bariatric-weighing","provider":"SelfiMed UK","version":"1.0","type":"link"}