{"product_id":"paykel-airvo-humidifier-fisher-2-new-water","title":"Fisher \u0026 Paykel Airvo 2 Humidifier with NEW Water Chamber \u0026 Breathing Circuit on Rollstand","description":"\u003cstyle\u003e\n  .product-wrapper {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n    font-size: 1.05rem;\n  }\n\n  .box-intro {\n    background: #eef3ff;\n    border: 1px solid #c7d3ff;\n    padding: 1.5rem;\n    border-radius: 6px;\n    margin-bottom: 1.6rem;\n  }\n\n  .box-highlight {\n    background: #f5f7fa;\n    border: 1px solid #d5d9e2;\n    padding: 1.3rem;\n    border-radius: 6px;\n    margin-bottom: 1.6rem;\n  }\n\n  .box-specs {\n    background: #f8f9fb;\n    border: 1px solid #cfd4dc;\n    padding: 1.3rem;\n    border-radius: 6px;\n    margin-bottom: 1.6rem;\n  }\n\n  .box-note {\n    background: #f5f7fa;\n    border: 1px solid #d5d9e2;\n    padding: 1.1rem 1.2rem;\n    border-radius: 6px;\n    margin-top: 1.2rem;\n  }\n\n  .product-wrapper img {\n    max-width: 100%;\n    height: auto;\n    display: block;\n    margin: 0.75rem 0 1.2rem;\n    float: none;\n  }\n\n  .product-wrapper ul {\n    margin: 0.5rem 0 0.75rem;\n    padding-left: 1.3rem;\n  }\n\n  .product-wrapper li {\n    margin-bottom: 0.5rem;\n  }\n\n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin-top: 0.6rem;\n    background: #ffffff;\n    border: 1px solid #dde3ef;\n    border-radius: 6px;\n    overflow: hidden;\n  }\n\n  .spec-table th,\n  .spec-table td {\n    text-align: left;\n    padding: 0.75rem 0.85rem;\n    border-bottom: 1px solid #eef2f7;\n    vertical-align: top;\n  }\n\n  .spec-table th {\n    background: #eef3ff;\n    border-bottom: 1px solid #c7d3ff;\n    font-weight: 700;\n  }\n\n  .spec-table tr:last-child td {\n    border-bottom: none;\n  }\n\n  .box-documents {\n    background: #f5f7fa;\n    border: 1px solid #d5d9e2;\n    padding: 1.2rem;\n    border-radius: 6px;\n    margin-top: 1.2rem;\n    margin-bottom: 1.6rem;\n  }\n\n  .pdf-doc-list {\n    list-style: none;\n    padding-left: 0;\n    margin: 0;\n  }\n\n  .pdf-doc-item {\n    background: #ffffff;\n    border: 1px solid #dde3ef;\n    border-radius: 4px;\n    padding: 0.6rem 0.75rem;\n    margin-bottom: 0.55rem;\n    display: flex;\n    align-items: flex-start;\n    gap: 0.6rem;\n  }\n\n  .pdf-icon {\n    width: 18px;\n    height: 18px;\n    display: inline-block;\n    flex: 0 0 18px;\n    margin-top: 2px;\n  }\n\n  .pdf-icon svg {\n    width: 100%;\n    height: 100%;\n    display: block;\n  }\n\n  .doc-link strong {\n    font-weight: 700;\n  }\n\n  .mini-links a {\n    display: inline-block;\n    margin: 0.25rem 0;\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"product-wrapper\" style=\"text-align: start;\"\u003e\n\u003ch2\u003eFisher \u0026amp; Paykel Airvo 2 Humidifier on Rollstand – High-Flow Nasal Therapy System\u003c\/h2\u003e\n\u003ch3\u003eIntegrated Heated Humidification and Flow Generation for Respiratory Care\u003c\/h3\u003e\n\u003cdiv class=\"box-intro\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eFisher \u0026amp; Paykel Airvo 2 Humidifier\u003c\/strong\u003e delivers high-flow oxygen therapy with built-in heated humidification and an integrated flow generator, removing the need for an external compressor. Supplied with a \u003cstrong\u003ehospital-grade rollstand\u003c\/strong\u003e, it provides mobile, precise, and comfortable respiratory support for adult and paediatric patients in \u003cstrong\u003eacute, step-down, or home care\u003c\/strong\u003e environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/FP-airvo-adult2.jpg?v=1763996088\" alt=\"Fisher \u0026amp; Paykel Airvo Humidifier\"\u003e\n\u003cdiv class=\"box-specs\"\u003e\n\u003cp\u003eIts \u003cstrong\u003eAirSpiral™ heated circuit\u003c\/strong\u003e helps prevent condensation while maintaining stable humidity, supporting reliable performance during prolonged therapy or higher acuity use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cdiv class=\"box-highlight\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Flow Range (2 to 60 L\/min):\u003c\/strong\u003e Supports both adult and paediatric high-flow therapy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Heated Humidifier:\u003c\/strong\u003e Delivers humidified gases to support comfort and airway conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Flow Generator:\u003c\/strong\u003e Operates without an external compressor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated AirSpiral™ Tubing:\u003c\/strong\u003e Dual-spiral design supports condensation management within the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Temperature Settings (31 °C, 34 °C, 37 °C):\u003c\/strong\u003e Adjustable for patient needs and comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Control Panel:\u003c\/strong\u003e Clear display of flow, temperature, and alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudible and Visual Alarms:\u003c\/strong\u003e Alerts for disconnection, temperature, flow faults, and power events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Blending Capability:\u003c\/strong\u003e Allows controlled FiO₂ adjustment using supplementary oxygen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile Rollstand:\u003c\/strong\u003e Adjustable stand with tray for clinical convenience.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/airvo-2-150612_1mg.jpg?v=1763996043\" alt=\"Fisher \u0026amp; Paykel Airvo 2 Humidifier\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"box-specs\"\u003e\n\u003ctable class=\"spec-table\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 60 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 °C, 34 °C, 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e295 × 170 × 175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 115 V \/ 220 to 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital LCD with indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeated AirSpiral circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptiflow™ nasal or tracheostomy interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRollstand with tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow, temperature, disconnection, power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eIncluded Components\u003c\/h3\u003e\n\u003cdiv class=\"box-specs\"\u003e\n\u003cul\u003e\n\u003cli\u003eFisher \u0026amp; Paykel Airvo 2 Humidifier (used)\u003c\/li\u003e\n\u003cli\u003eRollstand with tray (used)\u003c\/li\u003e\n\u003cli\u003eAirSpiral heated breathing tube (new)\u003c\/li\u003e\n\u003cli\u003eReusable or auto-fill humidification chamber (new)\u003c\/li\u003e\n\u003cli\u003ePower supply (used)\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eIdeal For\u003c\/h3\u003e\n\u003cdiv class=\"box-highlight\"\u003e\n\u003cul\u003e\n\u003cli\u003eAcute and high-dependency care units\u003c\/li\u003e\n\u003cli\u003eStep-down wards and long-term ventilation support\u003c\/li\u003e\n\u003cli\u003eHome high-flow oxygen therapy\u003c\/li\u003e\n\u003cli\u003eTracheostomy and humidified airway management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 0.875rem;\"\u003eHelpful Documents\u003c\/h2\u003e\n\u003cdiv class=\"box-documents\"\u003e\n\u003cul class=\"pdf-doc-list\"\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myairvo2-user-manual-ui-185045490.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003emyAirvo™ 2 User Instructions (PT100XX)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myairvokit1-user-instruction-ui-618167.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eAirSpiral™ Tube \u0026amp; Auto-Fill Chamber Kit User Instructions (MYAIRVOKIT1)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myopt9-nasal-cannula-user-instruction-ui-620895.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eOptiflow™+ Nasal Cannula User Instructions (MYOPT9 S\/M\/L)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myairspiral-user-instruction-ui-620898.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eAirSpiral™ Heated Tube User Instructions (MYAIRSPIRAL)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myopt9trache-user-instruction-ui-620896.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eOptiflow™+ Tracheostomy Interface User Instructions (MYOPT9TRACHE)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myairvochamber1-ui-621415-d1.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReusable Chamber User Instructions (MYAIRVOCHAMBER1)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"pdf-doc-item\"\u003e\n\u003cspan aria-hidden=\"true\" class=\"pdf-icon\"\u003e \u003csvg viewbox=\"0 0 24 24\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n          \u003cpath d=\"M6 2h9l5 5v15a2 2 0 0 1-2 2H6a2 2 0 0 1-2-2V4a2 2 0 0 1 2-2z\" fill=\"#fa0f00\"\u003e\u003c\/path\u003e\n          \u003cpath d=\"M15 2v6h6\" fill=\"#ffffff\"\u003e\u003c\/path\u003e\n          \u003ctext fill=\"#ffffff\" font-weight=\"700\" font-size=\"7\" y=\"17\" x=\"7\"\u003ePDF\u003c\/text\u003e\n        \u003c\/svg\u003e \u003c\/span\u003e \u003ca href=\"https:\/\/resources.fphcare.com\/content\/myopt9mask-user-instruction-ui-620897.pdf\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eOptiflow™+ Mask Interface Adapter User Instructions (MYOPT9MASK)\u003c\/strong\u003e \u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fisher \u0026 Paykel","offers":[{"title":"Without Pole Stand","offer_id":55020172149061,"sku":"FIR149502","price":479.99,"currency_code":"GBP","in_stock":true},{"title":"With Pole Stand","offer_id":55020172116293,"sku":"FIR149501","price":479.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/2716\/3717\/files\/Airvo_2_high-flow_therapy_device_with_heated_breathing_tube.jpg?v=1767164017","url":"https:\/\/selfimed.com\/uk\/products\/paykel-airvo-humidifier-fisher-2-new-water","provider":"SelfiMed UK","version":"1.0","type":"link"}