Schuco 120 Electrosurgery Unit
£399.99
This item
The Schuco 120 Electrosurgery Unit is a radiofrequency electrosurgical generator for minor and medium surgery, offering pure cut, blend, forced coagulation, soft coagulation and, with an adapter, bipolar coagulation. It is the unit widely used in minor operations rooms, dermatology and podiatry clinics, where one generator has to cover cutting, haemostasis and lesion work.
This listing is for the generator only. The complete pack is normally supplied with a reusable handle with finger switches, a footswitch, a 2 m power lead, a steel neutral electrode of 120 x 160 mm, a cable for a disposable neutral plate, an assorted pack of 10 electrodes of 5 cm and the user manual. None of that is supplied here, and the unit is pre-owned. It suits a buyer who already holds compatible accessories, or who is buying a second generator to sit alongside an existing set.
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included, and this item may require service and calibration. Planned maintenance, periodic electrical safety testing and ongoing maintenance under PUWER 1998 remain with the operating organisation.
Not usable on a patient as supplied
An electrosurgical generator turns mains power into a high frequency current that cuts and coagulates tissue through the electrode rather than by heat conducted from a hot tip. That distinction is the point of the technology. A pure cut waveform parts tissue with very little lateral thermal spread, so a specimen taken for histopathology arrives at the laboratory readable rather than charred. Adding coagulation into the same waveform gives a blend that cuts through a dry field, which is what makes larger excisions practical in a treatment room. Forced coagulation sears superficially for surface lesions, and soft coagulation drives deeper without carbonising, which is what seals a bleeding vessel.
In monopolar mode the current has to leave the patient somewhere, and that somewhere is the patient plate. The plate is not an accessory in the ordinary sense: it is half the circuit, and a plate that is poorly sited, partly lifted or of the wrong type concentrates the return current into a small area of skin. That is the mechanism behind return electrode burns, and it is why this generator monitors the plate circuit continuously and why the split plate design exists. A buyer taking a machine-only unit is therefore taking one half of a system, and the half being supplied is the half that cannot cause harm on its own.
The trade-off is straightforward and worth stating plainly. Machine only is the right purchase for a clinic that already runs Schuco 120 units and holds handpieces, plates and leads in stock, or for a service holding a spare generator against a breakdown. It is the wrong purchase for anyone setting up minor surgery from scratch, because the accessories then have to be sourced separately and will usually cost more assembled piecemeal than a complete pack. It is also the wrong purchase where bipolar work is the main requirement, since bipolar on this unit depends on an adapter and forceps that are not supplied, and it is not a substitute for a dedicated bipolar generator in a theatre setting.
Specification limited to what is confirmed
| Check | Interval |
|---|---|
| Inspect handpiece, electrode and plate leads for damaged insulation before connection | Before every procedure |
| Confirm plate siting, full contact and the monitoring indication | Before every procedure |
| Observe the self-check and the digital power reading at power-up | Before every session |
| Clean the case, panel and accessible sockets | After every session |
| Fit fresh single use electrodes, or reprocess reusable ones to the manufacturer instructions | Every patient |
| Electrical safety testing and verification of output against a test load | Annually, and after any repair or transport |
Intervals follow common practice for electrosurgical equipment and are adjusted to the manufacturer instructions and local medical device policy.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article