Please read and confirm before adding to cart
Measure your access points first
Please check the bed dimensions shown on the product page and measure your front door, hallways, stairways and room doorway before ordering. The dimensions provided are approximate and may vary slightly between models. We strongly recommend allowing extra clearance beyond the stated measurements to ensure the bed can be delivered and moved into the room safely.
Ground floor delivery only
Beds are delivered fully assembled to the ground floor only. Upper floor or room placement is not included.
Returns cost the original delivery fee
If the bed cannot fit into your home, return shipping is at your expense and the original delivery fee is non-refundable.
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Add the whole set in one go.
Linet Multicare Hospital Bed with Controller and Mattress
£1,199.99
This item
Squirrel Medical 8535 Inflatable Mattress Systems- Brand New
£299.99
The Linet Multicare is an intensive care bed built for critical care and high dependency environments. Its defining feature is lateral tilt, a controlled side to side movement of the mattress platform of up to 15 degrees each way, which turns the patient without the crew taking the load. That single function supports pulmonary therapy, pressure redistribution and repositioning in patients who cannot be turned manually. Full electric profiling covers backrest, knee break, height and Trendelenburg. Safe working load is 250 kg. This unit is pre-owned and is supplied with the controller and a compatible mattress.
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included unless this listing states that the unit has been serviced. Planned maintenance and periodic electrical safety testing remain with the operating organisation once the bed is in service.
Lateral tilt moves the mattress platform through roughly 15 degrees to either side under powered control. In practice it takes the effort out of turning a heavy or unstable ICU patient, and it makes postural drainage, back care and linen changes a job for fewer hands. It is also the route to pressure injury prevention in patients who cannot tolerate a manual turn, where even a small change of angle matters.
Backrest elevation includes auto-regression, so the deck sections shift as the backrest rises rather than dragging the patient up the bed. That reduces shear at the sacrum and limits abdominal compression, which is why the geometry matters as much as the surface in pressure care.
Configuration and variant
The Multicare shipped over several production years in a number of configurations, and figures given above are typical rather than unit specific. Features including CPR quick release, battery backup, a retractable fifth castor, integrated scales, bed exit alarm and foot controls were configuration dependent and are not confirmed as present on this unit. Where a specific function is essential, ask before ordering and the configuration and rating label will be checked. The bed is offered on the basis of the specification and photographs shown.
Siderails, mattress fit and entrapment risk
Bed rails only reduce risk when rail, frame and mattress are dimensionally compatible. A mattress outside the stated size range, or one deeper than 23 cm, reduces the effective rail height and opens gaps a patient can become trapped in. Check the effective rail height above the compressed mattress surface and check every gap against current national guidance on the safe use of bed rails, and reassess whenever the surface is changed, including any move to an active or overlay mattress. Bed rails are not appropriate for every patient and their use should follow an individual risk assessment.
Delivery and access
| Component | Action | Interval |
|---|---|---|
| Siderails | Check latching, movement and integrity, confirm gaps against the mattress in use | Before each use |
| Brakes and castors | Confirm the central brake holds, clear debris and thread from castor spindles | Weekly |
| Profiling and lateral tilt | Cycle every function through full travel and listen for actuator strain | Weekly |
| Mains lead, handset and panels | Inspect for damage, cracked housings and fluid ingress | Weekly |
| Mattress and cover | Decontaminate per local policy, inspect the cover for rips, staining and seam failure | Between patients |
| Mattress platform sections | Remove, clean and refit, confirming each section seats and locks correctly | Between patients |
| Frame and fixings | Inspect for cracks, corrosion, loose fasteners and deformation | Monthly |
| Planned maintenance and electrical safety test | Engineer service and test | Per local schedule |
The above is general guidance. The manufacturer instructions for use and the operating organisation's decontamination and maintenance policy take precedence. Any bed showing a fault should be taken out of service until it has been repaired and re-tested.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Written by people who bought from us.
Meical Equipment Advice and Guidance
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Read Article
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Read Article
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Read Article