Welch Allyn AM12 Acquisition Module Ref 919293-048-65 with Accessory in Box
£229.99
This item
The Welch Allyn AM12 Acquisition Module is the wired 12-lead ECG acquisition cable system designed for use with Welch Allyn ELI series electrocardiographs. It connects directly to compatible ELI ECG machines to capture real-time resting ECG data with lead fail indication, allowing straightforward patient hookup and reliable signal acquisition across all 12 leads. This variant is supplied with IEC-standard lead wires with banana plug connectors and is presented with accessories in box. The AM12 is a genuine Welch Allyn original part and is compatible with the Welch Allyn Diagnostic Cardiology Suite software environment.
| Specification | Detail |
|---|---|
| Manufacturer | Welch Allyn (a Baxter company) |
| Reference number | 919293-048-65 |
| Module type | AM12 wired acquisition module |
| Lead wire standard | IEC |
| Lead wire configuration | 10-wire, 12-lead with banana plugs |
| Compatible ECG systems | Welch Allyn ELI 230, ELI 250, ELI 280, ELI 380 |
| Connection type | Wired |
| Lead fail indicator | Yes (LED) |
| Applied part classification | Type CF defibrillation-proof |
| Safety standard | IEC 60601-1 |
Please note: This module is supplied with accessories in original box. It is compatible with IEC lead wire configurations. If your facility uses AHA lead wires, please confirm the correct variant before ordering.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article