24/7 Chat Available
24/7 Chat Available
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Add the whole set in one go.
Breas Vivo 60 Patient Ventilator on rollstand
£449.99
This item
The Breas Vivo 60 is a life-support ventilator for paediatric patients above 5 kg and for adults, delivering continuous or intermittent ventilatory support invasively or non-invasively. It is used in hospital, in the community and on the move, and is supplied here mounted on its rollstand.
Thirteen ventilation modes cover pressure and volume control, assisted and synchronised variants, target volume and CPAP, so a single device follows a patient across changing requirements rather than being swapped as the clinical picture moves. Exhaled volume is measured rather than assumed, which is what makes volume delivery on this class of ventilator trustworthy, and the trigger technology is tuned for synchronisation with a patient who is making respiratory effort of their own.
Paediatric capability is the part that distinguishes it from most homecare ventilators. Tidal volumes go down to 50 ml and controlled breath rates up to 60 breaths per minute, which covers small children as well as adults on the same platform.
Battery autonomy reaches 12 hours with the internal and click-on batteries together, and the unit is FAA compliant for use on commercial flights, so a ventilator-dependent patient can travel. On the rollstand it moves around a ward or a home and stands at the bedside without occupying a surface.
This unit is pre-owned. The notice below is the part to read before purchase, because a life-support ventilator carries obligations that a monitor or a trolley does not.
| Item | Detail |
|---|---|
| Manufacturer | Breas Medical AB, Sweden |
| Model | Vivo 60 |
| Device class | Life-support ventilator |
| Patient range | Paediatric above 5 kg, and adult |
| Platform | Vivo 50 and Vivo 60 share a service manual and a common chassis |
This is a life-support device and is not supplied ready for patient use. Before any patient is connected, the ventilator is commissioned by a qualified biomedical engineering or clinical technical service: performance verified against a test lung and a calibrated analyser, internal and click-on battery capacity confirmed under load, alarm function tested across the full alarm set, and electrical safety testing completed. No service history, calibration certificate or performance record accompanies this unit, and none of these checks has been carried out here.
Settings are entered by the responsible clinical service and never carried over. Mode, pressures, rates, volumes, trigger, backup settings and every alarm limit are set for the individual patient by the service responsible for their care, and any configuration left in the device from a previous patient is cleared or overwritten before use. A ventilator-dependent patient must have alternative means of ventilation immediately available at all times, including a manual resuscitator and, where the clinical plan requires it, a second ventilator.
Circuit, consumables and accessories. No patient circuit, filters, exhalation valve, humidifier, mask or tracheostomy interface is supplied. The circuit configuration must match the mode of ventilation and the patient, and is specified by the clinical service rather than chosen by catalogue. Single patient use items are never reissued between patients, and reusable parts are reprocessed strictly to the manufacturer's instructions before the device goes to a new patient.
Ongoing responsibilities. Once commissioned, the ventilator sits under the operating organisation's planned maintenance and equipment management arrangements, with periodic service to the manufacturer's schedule, electrical safety testing, battery condition monitoring and recorded pre-use checks. Duties under PUWER 1998 apply to equipment used at work. Where the device is placed with a patient at home, the supplying service is responsible for training, for the contingency plan and for the arrangements covering power failure and device failure.
| Brand | Breas Medical |
| Model | Vivo 60 |
| Device type | Life-support ventilator, invasive and non-invasive |
| Condition | Pre-owned |
| Patient population | Paediatric above 5 kg, and adult |
| Ventilation modes | PSV, PSV with target volume, PCV, PCV with target volume, PCV assisted, PCV assisted with target volume, SIMV PCV, VCV, VCV assisted, SIMV VCV, CPAP |
| Inspiratory pressure | 4 to 60 cm H2O |
| PEEP | 0 to 30 cm H2O adult, up to 20 cm H2O paediatric |
| Breath rate | 4 to 60 bpm |
| Backup rate in PSV | 4 to 60 bpm |
| Inspiratory time | 0.3 to 5 s |
| Target and tidal volume | 50 to 2500 ml |
| Flow pattern | Square or decelerating |
| Sigh function | On or off |
| Power | Mains supply, internal battery and click-on battery |
| Battery autonomy | Up to 12 hours with internal and click-on batteries combined |
| Air transport | FAA compliant for commercial flights |
| Dimensions (W x H x D) | 343 x 125 x 264 mm |
| Weight | 5.2 kg |
| Compliance | CE marked |
| Item | Quantity | Condition |
|---|---|---|
| Breas Vivo 60 ventilator | 1 | Used |
| Rollstand | 1 | Used |
| Power supply with mains cable | 1 | Used |
| Item | Detail | Status |
|---|---|---|
| Patient circuit | Tubing, exhalation valve and circuit accessories, specified by the clinical service | Not included |
| Consumables | Filters and single patient use items | Not included |
| Humidifier | Heated humidifier and chamber | Not included |
| Patient interface | Mask, headgear or tracheostomy connection | Not included |
| Commissioning, service and calibration | Verification against a test lung and analyser, and electrical safety testing | Not included |
| Service history and calibration certificate | None accompanies this unit | Not included |
Specifications can change without notice. Ask us for the current technical file.
Further documentation is available on request.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article