Avicenna Surgical D and E Instrument Tray, REF MED-D and E-200, Reusable 19 Piece Gynaecology Set, New
Avicenna Surgical D and E Instrument Tray, REF MED-D and E-200, Reusable 19 Piece Gynaecology Set, New
A complete reusable dilatation and evacuation instrument set from Avicenna Surgical, supplied new and individually packaged. The set covers the full procedural sequence in one tray: sponge holders and ovum forceps, two patterns of vulsellum forceps, a double ended Sims speculum, a graduated run of ten Pratts dilators from 9/11 through to 45/47, a stainless steel kidney dish and gallipot, and a side perforated wire DIN basket sized to take the whole set through a CSSD cycle. Buying the set as a tray rather than piece by piece means the dilator progression is complete, which is the part that matters clinically and the part most often found with gaps in a mixed instrument stock.
What is included
| Qty | Reference | Item | Condition |
|---|---|---|---|
| 2 | AVRUI-10-334 | Rampley sponge holder, polished finish, 25 cm | NEW |
| 1 | AVRUI-40-201 | McClintock ovum forceps, polished finish, 25 cm | NEW |
| 1 | AVRUI-40-205 | Teale vulsellum forceps, straight, 3:4 teeth, 24 cm | NEW |
| 1 | AVRUI-40-195 | Luer vulsellum forceps, 23 cm | NEW |
| 1 | AVRUI-40-125 | Sims speculum, double ended, medium | NEW |
| 1 | AVRUI-40-229 | Pratts dilator, double ended, 9/11 | NEW |
| 1 | AVRUI-40-230 | Pratts dilator, double ended, 13/15 | NEW |
| 1 | AVRUI-40-231 | Pratts dilator, double ended, 17/19 | NEW |
| 1 | AVRUI-40-232 | Pratts dilator, double ended, 21/23 | NEW |
| 1 | AVRUI-40-233 | Pratts dilator, double ended, 25/27 | NEW |
| 1 | AVRUI-40-234 | Pratts dilator, double ended, 29/31 | NEW |
| 1 | AVRUI-40-235 | Pratts dilator, double ended, 33/35 | NEW |
| 1 | AVRUI-40-236 | Pratts dilator, double ended, 37/39 | NEW |
| 1 | AVRUI-40-237 | Pratts dilator, double ended, 41/43 | NEW |
| 1 | AVRUI-40-238 | Pratts dilator, double ended, 45/47 | NEW |
| 1 | AVRUI-140-151 | Kidney dish, stainless steel, medium | NEW |
| 1 | AVRUI-140-160 | Gallipot, stainless steel, 80 mm diameter, 60 ml capacity | NEW |
| 1 | AVRUI-140-125 | Side perforated wire DIN basket, 300 x 300 x 60 mm | NEW |
What is not included
| Item | Detail | Status |
|---|---|---|
| Suction cannulae and tubing | Procedure specific single-use items | SOLD SEPARATELY |
| Tray liners and wraps | CSSD packaging consumables | SOLD SEPARATELY |
| Sterilisation indicators | Process indicators and integrators | SOLD SEPARATELY |
| Decontamination and sterilisation | The set is supplied non-sterile | NOT INCLUDED |
Supplied non-sterile, sterilise before use
- These instruments are supplied non-sterile. They must be decontaminated and sterilised in line with the receiving organisation's decontamination policy and the manufacturer instructions before any clinical use.
- The set is reusable and intended to be processed through a CSSD cycle. The wire DIN basket is sized to hold the full set through washing and sterilisation.
- For use by suitably qualified healthcare professionals only.
- Inspect every instrument before use for burrs, misalignment, damaged teeth and ratchet function, and withdraw any instrument that fails inspection.
New and boxed
The set is supplied new in the manufacturer's carton with each instrument individually packaged and labelled with its reference and lot number. Box contents are checked against the packing list before dispatch.
What the set covers
Specification
| Manufacturer | Avicenna Surgical |
| Set reference | MED-D and E-200 |
| Set type | Reusable dilatation and evacuation instrument tray |
| Pieces | 19, including the wire basket |
| Material | Stainless steel |
| Supplied | Non-sterile, individually packaged |
| Reprocessing | Reusable, CSSD processing required before use |
| Basket dimensions | 300 x 300 x 60 mm |
| Dilator range | Pratts, double ended, 9/11 to 45/47, ten instruments |
| Marking | UKCA and CE |
| Intended user | Suitably qualified healthcare professionals |
| Setting | Gynaecology theatres, day surgery units, women's health services |
| Condition | New, in original packaging |
Reprocessing and care guidance
| Stage | Action |
|---|---|
| Before first use | Remove all packaging, decontaminate and sterilise the full set |
| Point of use | Keep instruments moist after use to prevent soil drying onto surfaces and hinges |
| Cleaning | Process per local decontamination policy, opening every hinged instrument fully |
| Inspection | Check jaw alignment, teeth, ratchets and dilator tips for burrs and pitting |
| Lubrication | Apply instrument lubricant to hinges and box joints where policy requires |
| Sterilisation | Steam sterilise in the basket per the validated cycle for the load |
| Storage | Store dry and protected, with the set kept complete so dilator sizes are not separated |
| Withdrawal | Remove from service any instrument showing corrosion, cracking, a failed ratchet or a damaged tip |
The above is general guidance. The manufacturer instructions for use and the operating organisation's decontamination policy take precedence.