24/7 Chat Available
24/7 Chat Available
Brand new
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Philips Respironics DreamStation Humidifier Flip Lid Seal
£9.49
This item
Philips Respironics DreamStation Heated Tubing HT15
£47.99
This is the Philips Respironics flip lid seal for the DreamStation humidifier, a small consumable component that maintains the watertight closure of the humidifier chamber lid. When the original seal degrades or is lost, the chamber may not close correctly, leading to air leaks, reduced humidification and potential rainout. Replacing the seal restores a proper closure and supports consistent humidification throughout the night.
| Item | Detail | Condition |
|---|---|---|
| DreamStation humidifier flip lid seal | Philips Respironics OEM component, product code 1120617 | NEW |
| Item | Detail | Status |
|---|---|---|
| DreamStation humidifier water chamber | Chamber sold separately | NOT INCLUDED |
| DreamStation CPAP or APAP device | Machine sold separately | NOT INCLUDED |
| Heated tubing | Sold separately | NOT INCLUDED |
Supplied new. Contents checked against the packing list. Commissioning and fitment remain with the operating organisation or the end user following the manufacturer instructions.
The flip lid seal sits between the lid and the body of the DreamStation humidifier water chamber. Its purpose is to create an airtight closure so that the device can pressurise the chamber and deliver humidified air at the set level. A degraded or missing seal allows pressurised air to escape around the lid, which reduces effective humidification and may produce audible leaks during therapy.
Seals are a routine consumable. Philips recommends periodic inspection and replacement as part of standard chamber maintenance. The manufacturer instructions take precedence over any general guidance given here. Refer to the DreamStation humidifier user guide for the correct inspection interval and fitment procedure.
This seal is listed for the DreamStation humidifier. DreamStation and DreamStation 2 use different chamber designs. Confirm your chamber model before ordering. If you are uncertain, ask before ordering.
| Action | Detail | Interval |
|---|---|---|
| Inspect seal condition | Check for cracking, deformation or loss of elasticity | Weekly or per manufacturer schedule |
| Clean seal | Follow the humidifier cleaning protocol in the manufacturer instructions | As directed |
| Replace seal | Replace when seal shows visible degradation or when an air leak is detected at the lid | As needed |
The manufacturer instructions take precedence over the above general guidance.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article