Labcold Benchtop Intellicold Pharmacy Fridge - Refurbished
£449.99
This item
This Labcold IntelliCold benchtop pharmacy fridge holds vaccines and temperature sensitive medicines inside a controlled 2 to 8 degrees C range, with a factory set point of 5 degrees C. It suits GP surgeries, community pharmacies, clinics and vaccination centres that have to hold cold chain stock and produce a temperature record for it.
The IntelliCold touch screen controller monitors two probes, one of them a 1 m wandering probe that can be placed anywhere in the cabinet, and logs temperatures automatically around the clock for transfer to a computer. The unit is supplied pre-owned and has been checked in the Elarix workshop before dispatch.

| Item | Detail | Condition |
|---|---|---|
| Labcold IntelliCold pharmacy fridge | 36 litre benchtop cabinet with solid lockable door | REFURBISHED |
| IntelliCold touch screen controller | Fitted to the cabinet, with minimum and maximum display and alarms | USED |
| Secondary wandering probe | 1 m probe, positioned anywhere inside the cabinet | USED |
| Wall mounting brackets | Supplied for wall mounted installation in place of benchtop use | USED |
| Item | Detail | Status |
|---|---|---|
| Calibration certificate | No certificate is supplied with this unit | NOT INCLUDED |
| Reference thermometer | Independent calibrated thermometer for verifying the display | SOLD SEPARATELY |
| Shelving or baskets | Internal shelf configuration is not confirmed on this unit | NOT INCLUDED |
| Door key | Supply of a key with this unit is not confirmed | NOT INCLUDED |
| Data download lead or software | Method of transferring logged data to a computer is not confirmed | NOT INCLUDED |
| Wall fixings | Anchors suited to the wall construction on site | NOT INCLUDED |

Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included, and this item may require service and calibration. Planned maintenance, periodic electrical safety testing and ongoing maintenance under PUWER 1998 remain with the operating organisation.
Verify performance before any stock is loaded
A domestic fridge is built to keep food cold on average. It cycles well below 2 degrees C at the back of the cabinet and swings above 8 degrees C after the door is opened, and it gives no record of either. Vaccines lose potency at both ends of that swing, and a frozen vaccine is a discarded vaccine. A pharmacy fridge is built the other way round: fan assisted circulation to hold the whole interior inside a narrow band, a controller that watches the actual air the stock sits in, and a log that proves what happened overnight and at the weekend. When a batch is questioned months later, the log is the evidence.
The two probe arrangement is the part that matters most in daily use. One probe reports the cabinet, and the wandering probe is placed where the stock actually sits, in the busiest shelf or inside a glycol bottle, so the record reflects the medicine rather than the airflow. Minimum and maximum values are held and displayed, which is what a daily temperature check needs, and the alarms cover the three failures that spoil stock unnoticed: the temperature drifting, the door left ajar, and the power going off while the building is empty. Battery back-up keeps the controller and its alarms alive through a power cut, and the remote alarm contacts allow the unit to be tied into a building alarm system for out of hours cover.
Two trade-offs are worth stating. At 36 litres this is a small cabinet, sized for a treatment room or a single clinic session rather than a whole practice stock holding, and a solid door means checking stock requires opening it, which is better for light sensitive medicines but adds a warm air intrusion each time. And because the unit is pre-owned, it arrives without a calibration certificate, so the receiving organisation carries out its own verification against a calibrated reference before the readings are relied on for cold chain records. This is the wrong cabinet for frozen vaccine storage, for blood bank use, which is separately specified, and for laboratory samples that need a different range or a validated mapping report.
| Manufacturer | Labcold |
| Range | IntelliCold |
| Product type | Pharmacy refrigerator |
| Installation | Benchtop, or wall mounted using the supplied brackets |
| Condition | Pre-owned |
| Gross capacity | 36 litres |
| Temperature range | 2 to 8 degrees C |
| Set point | 5 degrees C |
| Controller | IntelliCold touch screen, locking after 30 seconds |
| Temperature probes | Two, including a 1 m secondary wandering probe |
| Data logging | Automatic, 24 hours a day, transferable to a computer |
| Alarms | High and low temperature, door open, power failure |
| Alarm back-up | Battery back-up for controller and alarms |
| Remote alarm contacts | Fitted |
| Cooling | Fan assisted |
| Defrost | Off-cycle automatic |
| Door | Solid, self-closing, lockable |
| Internal light | Fitted |
| Refrigerant | Contains no ammonia |
| External dimensions (H x W x D) | 540 x 450 x 510 mm |
| Internal dimensions (H x W x D) | 392 x 331 x 226 mm |
| Net weight | 30 kg |
Specification limited to what is confirmed
Delivery, lifting and wall mounting
| Task | Interval |
|---|---|
| Record current, minimum and maximum temperatures, then reset | Every working day |
| Check the door seal, self-closing action and that vents are clear | Weekly |
| Clean the interior and the controller surface | Weekly, and after any spill |
| Clean the condenser area and check for dust build-up | Quarterly |
| Verify the display against a calibrated reference thermometer | Annually, and after any move or repair |
| Download and archive the logged temperature data | To local cold chain policy |
Intervals follow common cold chain practice and are adjusted to the manufacturer instructions and local medicines policy.
Orders shipped outside the United Kingdom may attract import duty and local tax, which are charged by the destination country and are the buyer's responsibility.
SelfiMed offers a 30-day change-of-mind return policy on eligible items. To request a return, please contact us within 30 days of delivery. Items returned under this policy must be in the same condition as received and suitable for resale.
Please note that brand new items must remain unopened, unused and in their original packaging to be eligible for return. Once a new item has been opened or used, it may no longer qualify for return as new, and any accepted return may be subject to restocking fees.
For hygiene reasons, opened CPAP masks, CPAP parts and CPAP accessories, including tubing, filters and humidifier chambers, cannot be returned.
Return shipping costs are the responsibility of the customer.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
SelfiMed Ltd, trading as SelfiMed UK, supplies medical equipment, replacement parts and accessories but does not provide medical advice, diagnosis or treatment. Customers are responsible for ensuring that they are legally authorised to purchase and use any equipment supplied and for complying with all applicable regulations in their country. Certain medical devices may require a valid prescription or clinical directive before dispatch. Components, accessories and kits are supplied as replacement or accessory items unless expressly stated otherwise, and correct assembly, calibration, commissioning and application remain the responsibility of the user or an appropriately qualified professional.
All equipment must be used, maintained and cleaned in accordance with the manufacturer’s instructions. SelfiMed UK accepts no liability for misuse, incorrect assembly, mishandling, unauthorised modification or use outside the manufacturer’s intended purpose, and does not guarantee suitability for any particular clinical outcome unless confirmed in writing. Pre-owned or refurbished equipment should not be used for emergency or critical care without appropriate professional oversight and commissioning. Customers should obtain advice from a qualified healthcare professional or medical device technician where required and assume responsibility for the lawful, safe and appropriate use of the products purchased.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article