Dentra Extraction Forceps Fig 73 Lower Molars, Hawk's Bill
Dentra Extraction Forceps Fig 73, Lower Molars, Hawk's Bill
Dentra Fig 73 is a Hawk's Bill extraction forceps for lower molars. The Hawk's Bill name describes the angled beaks that curve down onto the tooth from above, which is what a mandibular molar requires: the operator works from over the arch rather than in line with it, and the beaks have to reach around a wide, often two-rooted tooth without slipping to the crown. Fig 73 carries one of the widest beak profiles in the extraction range, cross serrated on both faces, so grip is spread across the tooth surface instead of concentrated on one point. That distribution is what gives controlled force during socket expansion rather than a sudden crown fracture.
What is included
| Item | Detail | Condition |
|---|---|---|
| Dentra Fig 73 forceps | One extraction forceps for lower molars, Hawk's Bill beaks, REF 60073 | NEW |
What is not included
| Item | Detail | Status |
|---|---|---|
| Sterilisation | The instrument is supplied non-sterile | NOT INCLUDED |
| Other figure patterns | Forceps for other teeth and roots | SOLD SEPARATELY |
| Elevators and luxators | Instruments used before forceps application | SOLD SEPARATELY |
| Instrument tray or basket | Tray, wire basket and reprocessing consumables | SOLD SEPARATELY |
Supplied non-sterile, sterilise before use
- This instrument is supplied non-sterile. It must be decontaminated and sterilised in line with the receiving practice's decontamination policy before any clinical use, including before first use.
- For use by a suitably qualified dental professional. Extraction technique, case selection and instrument choice are clinical decisions.
- Inspect the beaks, the tips, the joint and the handle alignment before each use. Withdraw from service any instrument with a chipped or misaligned beak, a loose joint or visible corrosion.
- Forceps are designed for the pattern of tooth they name. Applying a forceps to a tooth it was not shaped for increases the risk of crown fracture and of damage to the instrument.
Where Fig 73 is used
Fig 73 is the general lower molar forceps, used on either side of the mandible. It is the instrument most practices reach for on a routine mandibular first or second molar where the crown is intact enough to grip and the roots do not require a furcation approach.
Two design points do the work. The Hawk's Bill angle brings the beaks onto the tooth from above at the angle a mandibular molar is actually approached, so the operator's wrist stays neutral and the force applied runs down the long axis of the tooth rather than across it. The wide cross serrated beaks then hold that position. Where a narrower beak concentrates load on a small area of enamel and invites a crown fracture, a wide beak spreads it, which is why this pattern is favoured for molars with substantial restorations.
Where the tooth is more compromised, or where the operator wants purchase in the furcation rather than on the crown, a cow horn pattern is the alternative approach. Both have a place, and most practices carry both.
Key features
Specification
| Brand | Dentra |
| Product | Extraction forceps, Fig 73 |
| Reference | 60073 |
| Indication | Lower molars, either side |
| Beak style | Hawk's Bill, angled, wide, cross serrated |
| Material | Stainless steel |
| Reprocessing | Reusable, steam sterilisable |
| Supplied | Non-sterile, single instrument |
| Intended user | Suitably qualified dental professionals |
| Condition | New |
Specification limited to what is confirmed
Overall length, beak width, joint type, the forceps pattern designation and the exact steel grade are not stated here pending confirmation against the production record and material certificate, and should not be assumed from the description above. Ask before ordering if any of these figures is needed.
Reprocessing and care
| Stage | Action |
|---|---|
| Before first use | Remove all packaging, decontaminate and sterilise |
| Point of use | Keep the instrument moist after use so blood and debris do not dry into the serrations and the joint |
| Cleaning | Process per the practice decontamination policy, with the joint opened fully so the hinge is reached |
| Inspection | Check beak alignment, serration condition, tip integrity and joint movement |
| Lubrication | Apply instrument lubricant to the joint where the local policy requires it |
| Sterilisation | Steam sterilise per the validated cycle for the load, with the instrument in the open position |
| Storage | Store dry and protected, avoiding contact that could chip a beak tip |
| Withdrawal | Remove from service on any sign of corrosion, cracking, beak misalignment or a slack joint |
The above is general guidance. The practice decontamination policy and current national guidance on decontamination in primary care dental practices take precedence.
Dentra range
Dentra is the dental instrument range from Elarix Medical. Extraction forceps are supplied by figure number across the English and American patterns, alongside orthodontic pliers and cutters and prosthodontic measuring instruments. Every item is individually referenced and barcoded, so a repeat order is placed against a code rather than a description.