Labcold Benchtop Intellicold Pharmacy Fridge - Refurbished
Labcold IntelliCold Benchtop Pharmacy Fridge, 36 Litres, Pre-Owned
This Labcold IntelliCold benchtop pharmacy fridge holds vaccines and temperature sensitive medicines inside a controlled 2 to 8 degrees C range, with a factory set point of 5 degrees C. It suits GP surgeries, community pharmacies, clinics and vaccination centres that have to hold cold chain stock and produce a temperature record for it.
The IntelliCold touch screen controller monitors two probes, one of them a 1 m wandering probe that can be placed anywhere in the cabinet, and logs temperatures automatically around the clock for transfer to a computer. The unit is supplied pre-owned and has been checked in the Elarix workshop before dispatch.

What is included
| Item | Detail | Condition |
|---|---|---|
| Labcold IntelliCold pharmacy fridge | 36 litre benchtop cabinet with solid lockable door | REFURBISHED |
| IntelliCold touch screen controller | Fitted to the cabinet, with minimum and maximum display and alarms | USED |
| Secondary wandering probe | 1 m probe, positioned anywhere inside the cabinet | USED |
| Wall mounting brackets | Supplied for wall mounted installation in place of benchtop use | USED |
What is not included
| Item | Detail | Status |
|---|---|---|
| Calibration certificate | No certificate is supplied with this unit | NOT INCLUDED |
| Reference thermometer | Independent calibrated thermometer for verifying the display | SOLD SEPARATELY |
| Shelving or baskets | Internal shelf configuration is not confirmed on this unit | NOT INCLUDED |
| Door key | Supply of a key with this unit is not confirmed | NOT INCLUDED |
| Data download lead or software | Method of transferring logged data to a computer is not confirmed | NOT INCLUDED |
| Wall fixings | Anchors suited to the wall construction on site | NOT INCLUDED |

Checked before dispatch
- Powered on and run down to the set point, then held to confirm the cabinet reaches and maintains temperature.
- Touch screen controller, minimum and maximum display and probe readings checked.
- High and low temperature, door open and power failure alarms triggered and observed.
- Door seal, self-closing action, lock and internal light checked.
- Interior and exterior cleaned, and the unit inspected for damage.
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included, and this item may require service and calibration. Planned maintenance, periodic electrical safety testing and ongoing maintenance under PUWER 1998 remain with the operating organisation.
Verify performance before any stock is loaded
- Run the cabinet empty in its final position until the temperature is stable, then check the displayed reading against an independent calibrated thermometer before medicines are placed inside.
- Accuracy of the readings used for cold chain records rests with the operating organisation, since no calibration certificate is supplied with this unit.
- Stock is not loaded on a unit that has just been moved or tilted, and the alarms are confirmed working first.
Why a pharmacy fridge rather than a domestic one
A domestic fridge is built to keep food cold on average. It cycles well below 2 degrees C at the back of the cabinet and swings above 8 degrees C after the door is opened, and it gives no record of either. Vaccines lose potency at both ends of that swing, and a frozen vaccine is a discarded vaccine. A pharmacy fridge is built the other way round: fan assisted circulation to hold the whole interior inside a narrow band, a controller that watches the actual air the stock sits in, and a log that proves what happened overnight and at the weekend. When a batch is questioned months later, the log is the evidence.
The two probe arrangement is the part that matters most in daily use. One probe reports the cabinet, and the wandering probe is placed where the stock actually sits, in the busiest shelf or inside a glycol bottle, so the record reflects the medicine rather than the airflow. Minimum and maximum values are held and displayed, which is what a daily temperature check needs, and the alarms cover the three failures that spoil stock unnoticed: the temperature drifting, the door left ajar, and the power going off while the building is empty. Battery back-up keeps the controller and its alarms alive through a power cut, and the remote alarm contacts allow the unit to be tied into a building alarm system for out of hours cover.
Two trade-offs are worth stating. At 36 litres this is a small cabinet, sized for a treatment room or a single clinic session rather than a whole practice stock holding, and a solid door means checking stock requires opening it, which is better for light sensitive medicines but adds a warm air intrusion each time. And because the unit is pre-owned, it arrives without a calibration certificate, so the receiving organisation carries out its own verification against a calibrated reference before the readings are relied on for cold chain records. This is the wrong cabinet for frozen vaccine storage, for blood bank use, which is separately specified, and for laboratory samples that need a different range or a validated mapping report.
Key features
Technical specifications
| Manufacturer | Labcold |
| Range | IntelliCold |
| Product type | Pharmacy refrigerator |
| Installation | Benchtop, or wall mounted using the supplied brackets |
| Condition | Pre-owned |
| Gross capacity | 36 litres |
| Temperature range | 2 to 8 degrees C |
| Set point | 5 degrees C |
| Controller | IntelliCold touch screen, locking after 30 seconds |
| Temperature probes | Two, including a 1 m secondary wandering probe |
| Data logging | Automatic, 24 hours a day, transferable to a computer |
| Alarms | High and low temperature, door open, power failure |
| Alarm back-up | Battery back-up for controller and alarms |
| Remote alarm contacts | Fitted |
| Cooling | Fan assisted |
| Defrost | Off-cycle automatic |
| Door | Solid, self-closing, lockable |
| Internal light | Fitted |
| Refrigerant | Contains no ammonia |
| External dimensions (H x W x D) | 540 x 450 x 510 mm |
| Internal dimensions (H x W x D) | 392 x 331 x 226 mm |
| Net weight | 30 kg |
Specification limited to what is confirmed
- Model reference, refrigerant type and gas charge, electrical supply and power rating, ambient climate class, sound level and energy consumption are not confirmed for this unit and have been left out rather than estimated.
- Internal shelf configuration, supply of a door key, and the method of downloading logged data to a computer are not confirmed.
- Any of these can be checked against the rating label and the unit itself on request.
Condition and history
Delivery, lifting and wall mounting
- The cabinet weighs 30 kg. Two people are needed to receive it, lift it onto a bench and position it.
- Wall mounting is carried out by a competent person, onto a wall able to carry the loaded weight of the cabinet, using fixings selected for the wall construction. Fixings are not supplied.
- Leave the clearance around the cabinet that the manufacturer instructions require so the condenser can shed heat, and allow the unit to stand upright before it is switched on after transport.
Routine checks and care
| Task | Interval |
|---|---|
| Record current, minimum and maximum temperatures, then reset | Every working day |
| Check the door seal, self-closing action and that vents are clear | Weekly |
| Clean the interior and the controller surface | Weekly, and after any spill |
| Clean the condenser area and check for dust build-up | Quarterly |
| Verify the display against a calibrated reference thermometer | Annually, and after any move or repair |
| Download and archive the logged temperature data | To local cold chain policy |
Intervals follow common cold chain practice and are adjusted to the manufacturer instructions and local medicines policy.