SKU BDI2234A02

BD Alaris NeXus CC Syringe Driver Mfd. 2022

Original price £349.99 - Original price £349.99
Original price
£349.99
£349.99 - £349.99
Current price £349.99
Availability:
in stock, ready to be shipped

BD Alaris neXus CC Syringe Pump, Pre-Owned 2022 Unit with Guardrails and Online Pressure Monitoring

The BD Alaris neXus CC is a precision syringe pump for controlled delivery of fluids, medications, parenteral nutrition and blood products across adult, paediatric and neonatal populations. It takes 5 ml to 50 ml Luer lock syringes and runs flow rate, volume over time, dose calculation and preconfigured protocol modes. Its defining capability is online pressure monitoring: SMART detection identifies whether a pressure sensing disc extension set or a standard set is fitted, giving early occlusion detection and reducing post-occlusion bolus risk. Guardrails hard and soft limits operate against institution-defined thresholds without needing a permanent network connection. This unit is dated 2022.

What is included

Item Detail Condition
Alaris neXus CC syringe pump BD syringe pump, 2022 unit, with internal NiMH battery fitted USED
Mains lead AC power lead for the pump USED

What is not included

Item Detail Status
Syringes Approved three-piece Luer lock syringes, 5 ml to 50 ml SOLD SEPARATELY
Pressure disc extension sets Sets required for online pressure monitoring SOLD SEPARATELY
Standard extension sets Sets for conventional occlusion detection SOLD SEPARATELY
Gateway Workstation Docking workstation for multi-pump working SOLD SEPARATELY
MRI Capsule Enclosure for continuity of infusion during imaging SOLD SEPARATELY
Syringe lock box Only for use when the pump is docked to a Gateway Workstation SOLD SEPARATELY
Pole clamp and mounting hardware Drip stand or rail mounting SOLD SEPARATELY
Drug library dataset Institution-specific Guardrails dataset and its deployment SOLD SEPARATELY
Service and calibration Engineer service, performance verification and certification SOLD SEPARATELY

Checked before dispatch

  • Cleaned and inspected.
  • Powered up and function tested, including battery operation and alarm response.
  • Syringe carriage, plunger grip and barrel clamp checked for free movement and secure hold.
  • Mains lead, plug, keypad and display visually inspected for damage.

These are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service and calibration is not included unless this listing states that the unit has been serviced. Delivery accuracy verification, planned maintenance and periodic electrical safety testing remain with the operating organisation once the pump is in service.

Clinical use

  • For use by qualified clinical personnel only.
  • Only approved three-piece Luer lock syringes should be used. Syringe brand and barrel geometry directly affect delivery accuracy, and using a syringe outside the approved range can produce a dosing error.
  • The Guardrails drug library is institution-specific. The receiving organisation must load and verify its own dataset and profiles before clinical use, rather than relying on whatever dataset is present on a pre-owned unit.

Key features

Online pressure monitoring with SMART detection of pressure disc or standard extension sets, across 11 configurable levels from L0 to L10, 50 to 1000 mmHg, for early occlusion detection.
BACK OFF function releasing pressure built up behind an occlusion, which limits the bolus delivered when the line clears. On a neonatal or vasoactive infusion this is the difference between a nuisance alarm and a clinical event.
FAST START taking up mechanical slack between the drive mechanism and the syringe plunger at the start of an infusion, cutting start-up delay at low flow rates.
Guardrails safety limits with configurable hard and soft alerts against institution-defined thresholds, working without a permanent network connection.
Drug library to 3,000 setups across 30 profiles, so a single fleet configuration can cover adult, paediatric, neonatal and theatre areas.
Multiple programming modes covering flow rate, volume over time, dose calculation, loading dose, KVO and VTBI with Stop, KVO or Continue end options.
Additional dose units including kcal and mEq alongside standard units, which matters for parenteral nutrition.
Wi-Fi connectivity for automatic transmission of infusion data to hospital clinical information systems through the Alaris Communication Engine.
Gateway Workstation compatible for organised multi-pump working at the bedside.
MRI Capsule compatible, supporting continuity of intravenous therapy during imaging.
Internal NiMH battery giving up to 6 hours at 5.0 ml/h and recharging to 90 per cent in 2.5 hours, charging automatically on AC power.
5 ml to 50 ml syringe range across adult, paediatric and neonatal use.
IP32 rated, protected against solid objects above 2.5 mm and water spray up to 15 degrees from vertical, rising to IP33 with the AC power cable retainer kit.
Flow rate accuracy of plus or minus 2 per cent at 25 ml/h, tested to IEC 60601-2-24.

Technical specifications

Manufacturer BD, Becton, Dickinson and Company
Model Alaris neXus CC
Device type Syringe infusion pump
Year of manufacture 2022
Patient population Adult, paediatric and neonatal
Syringe compatibility 5 ml to 50 ml Luer lock, approved single-use three-piece syringes
Flow rate accuracy Plus or minus 2 per cent at 25 ml/h, per IEC 60601-2-24
Pressure monitoring L0 to L10, 50 to 1000 mmHg, 11 levels
Drug library capacity 3,000 setups across 30 profiles
Battery type NiMH rechargeable, changeable at service
Battery life Up to 6 hours at 5.0 ml/h
Battery recharge time 2.5 hours from discharge to 90 per cent
Mains power supply 115 to 230 V AC, 50 to 60 Hz, 10 VA nominal
Dimensions, W x H x D 335 x 121 x 200 mm
Weight 2.4 kg
Ingress protection IP32, IP33 with AC power cable retainer kit
Connectivity Wi-Fi, RS232, nurse call
Standard compliance IEC 60601-2-24
Condition Pre-owned

Compatible accessories

  • Gateway Workstation
  • MRI Capsule
  • Syringe lock box, for use only when the pump is docked to a Gateway Workstation
  • Extension sets with pressure disc, for online pressure monitoring
  • Standard extension sets, for conventional occlusion detection
Battery condition. The internal NiMH pack is pre-owned. Usable capacity in any rechargeable cell falls with age and cycle count, so the runtime achieved will be below the 6 hour figure quoted for a fresh pack and cannot be stated for this unit. Where mains independence matters, budget for a fresh battery pack at first service.
Condition and history. A pre-owned unit from clinical service, cleaned and inspected. Cosmetic marking consistent with previous use should be expected. Ongoing maintenance should follow the operating organisation's medical device management policy and the duties under PUWER 1998. The photographs form part of the description and show the actual condition of the item offered.

Routine care guidance

Component Action Interval
Syringe carriage and plunger grip Inspect for residue, free movement and secure hold on the plunger flange Before each use
Alarms Confirm audible and visual alarms operate at power-up self test Before each use
Battery Return to mains after use, check the charge indicator and note any drop in runtime After each use
Housing, keypad and display Wipe down per local policy, inspect for cracks, fluid ingress and worn legends Between patients
Mains lead and plug Inspect for damage, strain at the entry point and secure retention Weekly
Drug library Confirm the loaded dataset and profile match the current institutional version Per local policy
Performance verification and electrical safety test Engineer service, delivery accuracy check and calibration Per local schedule

The above is general guidance. The manufacturer instructions for use and the operating organisation's medical device management policy take precedence. Any pump showing a fault, an unexplained alarm pattern or a suspected accuracy problem should be taken out of service until it has been tested.