In the box: Breas Vivo 60 ventilator, Rollstand and 1 more.

Warranty

The warranty depends on the item's condition. This item's row is highlighted.

ItemWarrantyCovers
Brand new, other brandsManufacturer'sAs set by the maker
Brand new, Alvera6 monthsFaults in materials or manufacture
New (other)12 monthsFaults in normal use
Like new and refurbished6 monthsFaults in normal use
Pre-owned90 daysFaults in normal use
Missing parts or with defects30 daysFaults other than those listed on the page

Alvera items are covered by Elarix Medical, the maker of Alvera. Other conditions are covered by SelfiMed. Every warranty starts on the day of delivery.

Not covered

  • Normal wear: cushions and pillows soften and seal less well with use, and headgear stretches. This is why they are replaced on a schedule.
  • Damage from cleaning with alcohol, bleach, scented soap or a dishwasher.
  • Drops, cuts, crushing, or changes made to the product.
  • The wrong size or model ordered.

How to claim

Email info@selfimed.com with your order number and a clear photo or short video of the fault. If we ask for the item back, please clean it first.

Returns and refunds

Opened or used CPAP accessories can't be returned. Masks, cushions, nasal pillows, tubing, filters and anything that touches the airway are sealed for hygiene and cannot come back once the seal is broken, even if unused.

  • Change of mind: 30 days from delivery on UK orders. You pay the return postage.
  • Opened new items: a deduction of up to 40% may apply; from day 15 to day 30, 40%.
  • Faulty or not as described: full refund within 30 days, and we pay the return postage. After that, the warranty applies.
  • International orders: no change-of-mind returns.

Full terms: returns and warranty policy. These terms do not affect your statutory rights.

All products / Ventilator machine

Breas Vivo 60 Patient Ventilator on rollstand

BreasSKU BRV126401
Price
£44999£599.99Save 25%

−10%at checkout · BLACKFRIDAY10

Black Friday · ends Monday 30 November, 23:59

Price shown excludes VAT.

VAT relief available on this product

Eligible customers can claim VAT relief on this product at checkout.

Quantity
Unit price£449.99
Total£449.99
You save£0.00

Free UK mainland delivery on orders over £1,000

Prefer a quote?

Frequently bought together

Add the whole set in one go.

Total for the set £0.00

Key attributes
Brand
Breas
Category
Ventilator machine
SKU
BRV126401
Options
2 to choose from

Breas Vivo 60 Life-Support Ventilator on Rollstand, Pre-Owned

The Breas Vivo 60 is a life-support ventilator for paediatric patients above 5 kg and for adults, delivering continuous or intermittent ventilatory support invasively or non-invasively. It is used in hospital, in the community and on the move, and is supplied here mounted on its rollstand.

Thirteen ventilation modes cover pressure and volume control, assisted and synchronised variants, target volume and CPAP, so a single device follows a patient across changing requirements rather than being swapped as the clinical picture moves. Exhaled volume is measured rather than assumed, which is what makes volume delivery on this class of ventilator trustworthy, and the trigger technology is tuned for synchronisation with a patient who is making respiratory effort of their own.

Paediatric capability is the part that distinguishes it from most homecare ventilators. Tidal volumes go down to 50 ml and controlled breath rates up to 60 breaths per minute, which covers small children as well as adults on the same platform.

Battery autonomy reaches 12 hours with the internal and click-on batteries together, and the unit is FAA compliant for use on commercial flights, so a ventilator-dependent patient can travel. On the rollstand it moves around a ward or a home and stands at the bedside without occupying a surface.

This unit is pre-owned. The notice below is the part to read before purchase, because a life-support ventilator carries obligations that a monitor or a trolley does not.

References

Item Detail
Manufacturer Breas Medical AB, Sweden
Model Vivo 60
Device class Life-support ventilator
Patient range Paediatric above 5 kg, and adult
Platform Vivo 50 and Vivo 60 share a service manual and a common chassis

Features

  • Life-support ventilation for paediatric and adult patients, invasive or non-invasive, in hospital, at home and in transit.
  • Thirteen ventilation modes, spanning pressure support, pressure control, volume control, assisted and synchronised variants, target volume and CPAP, so one device follows the patient as requirements change.
  • Measured exhaled volume, rather than delivered volume alone, which is what allows volume targets to be relied upon in a leak-prone circuit.
  • Responsive trigger technology, for synchronisation with a patient making their own respiratory effort, which is the difference between support and fighting the ventilator.
  • Paediatric capability from 50 ml tidal volume and controlled rates to 60 breaths per minute, covering small children on the same platform as adults.
  • Up to 12 hours of battery autonomy with the internal and click-on batteries combined, which covers a working day away from mains power.
  • FAA compliant for use on commercial flights, so a ventilator-dependent patient can travel.
  • Low noise in operation, which matters most in a bedroom where the device runs every night.
  • Supplied on its rollstand, so the ventilator moves between rooms and stands at the bedside without taking up a surface.

Important notice

This is a life-support device and is not supplied ready for patient use. Before any patient is connected, the ventilator is commissioned by a qualified biomedical engineering or clinical technical service: performance verified against a test lung and a calibrated analyser, internal and click-on battery capacity confirmed under load, alarm function tested across the full alarm set, and electrical safety testing completed. No service history, calibration certificate or performance record accompanies this unit, and none of these checks has been carried out here.

Settings are entered by the responsible clinical service and never carried over. Mode, pressures, rates, volumes, trigger, backup settings and every alarm limit are set for the individual patient by the service responsible for their care, and any configuration left in the device from a previous patient is cleared or overwritten before use. A ventilator-dependent patient must have alternative means of ventilation immediately available at all times, including a manual resuscitator and, where the clinical plan requires it, a second ventilator.

Circuit, consumables and accessories. No patient circuit, filters, exhalation valve, humidifier, mask or tracheostomy interface is supplied. The circuit configuration must match the mode of ventilation and the patient, and is specified by the clinical service rather than chosen by catalogue. Single patient use items are never reissued between patients, and reusable parts are reprocessed strictly to the manufacturer's instructions before the device goes to a new patient.

Ongoing responsibilities. Once commissioned, the ventilator sits under the operating organisation's planned maintenance and equipment management arrangements, with periodic service to the manufacturer's schedule, electrical safety testing, battery condition monitoring and recorded pre-use checks. Duties under PUWER 1998 apply to equipment used at work. Where the device is placed with a patient at home, the supplying service is responsible for training, for the contingency plan and for the arrangements covering power failure and device failure.