24/7 Chat Available
24/7 Chat Available
Brand new
−10%at checkout · BLACKFRIDAY10
Black Friday · ends Monday 30 November, 23:59
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
−10%at checkout · BLACKFRIDAY10
Black Friday · ends Monday 30 November, 23:59
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Free UK mainland delivery on orders over £300
Add the whole set in one go.
Walker Electronics QC Ultrasonic Cleaner Water Bath
£79.99
The Dentra Apollo gauge is a prosthodontic measuring instrument for recording the vertical dimension of occlusion. Vertical dimension is the distance between two marked facial points, conventionally one on the fixed maxilla and one on the mobile mandible, and getting it right is one of the more consequential judgements in denture and full mouth work. Set it too low and the face collapses and the patient over-closes; set it too high and there is no freeway space, the teeth clash during speech, and the patient cannot tolerate the prosthesis. The gauge replaces eye estimation with a direct millimetre reading: two adjustable markers locate the reference points, the scale reads lower face height, and a locking mechanism holds the figure so it survives the transfer to the record.
Before use
Vertical dimension is measured in two states. Rest vertical dimension is recorded with the mandible in physiological rest position. Occlusal vertical dimension is recorded with the teeth or the record rims in occlusion. The difference between the two is the freeway space, and it is that difference, not either figure alone, that tells the clinician whether the prosthesis will be tolerated.
Establishing both figures requires the same two reference points to be located reliably on each occasion. That is what the adjustable markers do. The scale then gives a number in millimetres rather than an impression, which makes the record reproducible: the same clinician gets the same figure at the next appointment, and a second clinician or the laboratory can work to it.
The instrument belongs to a long line of prosthodontic measuring devices going back to the Willis gauge of 1935, which introduced the idea of measuring lower face height directly rather than judging it. Modern gauges keep the principle and add a locking scale.
| Stage | Action |
|---|---|
| Before first use | Remove all packaging, decontaminate and sterilise |
| Point of use | Rinse promptly so debris does not dry into the scale engraving and the locking mechanism |
| Cleaning | Process per the practice decontamination policy, with the markers moved through their travel so the slide is reached |
| Inspection | Check scale legibility, marker tip condition and that the lock holds a setting under light pressure |
| Lubrication | Apply instrument lubricant to the sliding mechanism where the local policy requires it |
| Sterilisation | Steam sterilise per the validated cycle for the load |
| Storage | Store dry and protected, keeping the marker tips clear of contact with heavier instruments |
| Withdrawal | Remove from service on corrosion, an illegible scale, a bent marker or a lock that will not hold |
The above is general guidance. The practice decontamination policy and current national guidance on decontamination in primary care dental practices take precedence.
Dentra is the dental instrument range from Elarix Medical. Prosthodontic measuring instruments are supplied alongside extraction forceps by figure number across adult and children's patterns, and orthodontic pliers and cutters. Every item is individually referenced and barcoded, so a repeat order is placed against a code rather than a description.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
This item is brand new and comes with the manufacturer's warranty.
Read the full returns and warranty policy
This does not affect your statutory rights.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Written by people who bought from us.
Meical Equipment Advice and Guidance
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Read Article
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Read Article
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Read ArticleSelfiMed UK
BLACK FRIDAY
+ up to −80% on selected items, no code needed
Join our list for deal alerts, restocks and CPAP tips. Your code appears straight away.
Free UK mainland delivery over £300 · next-day dispatch before 1pm
By signing up you agree to receive marketing emails from SelfiMed UK. Unsubscribe at any time. Code valid on all products until Monday 30 November 23:59. One discount per item: items already at −50% or −80% keep that deal instead.
It's already in your basket, so 10% comes off at checkout.
Valid on all products. One discount per item. Ends Monday 30 November 23:59.