Siemens Healthcare DCA Advantage Analyser
£429.99
This item
The Siemens DCA Advantage is a point-of-care analyser for HbA1c and microalbumin/creatinine ratio testing, designed for use in GP surgeries, diabetes clinics and outpatient settings. Using a 1 µl fingerstick whole blood sample with no preparation or reagent pipetting, it delivers HbA1c results in 6 minutes and microalbumin/creatinine ratio results in 7 minutes, enabling glycaemic monitoring and early kidney disease detection during the patient consultation. Single-use test cartridges contain all reagents and are automatically calibrated via a lot-specific calibration card, eliminating the need for manual calibration procedures. A built-in thermal printer generates a patient result record at the end of each test. The DCA Advantage is a discontinued model now superseded by the DCA Vantage; reagents and consumables remain available. This unit is sold as used.
| Specification | Detail |
|---|---|
| Manufacturer | Siemens Healthcare Diagnostics |
| Model | DCA Advantage |
| Status | Discontinued (superseded by DCA Vantage) |
| Tests available | HbA1c (whole blood); Microalbumin/Creatinine (urine) |
| Sample volume (HbA1c) | 1 µl fingerstick whole blood |
| HbA1c result time | 6 minutes |
| A:C ratio result time | 7 minutes |
| Calibration | Automatic via lot-specific calibration card |
| Printer | Built-in thermal |
| Interface | RS232 |
| HbA1c certification | NGSP certified |
| Condition | Used |
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article