24/7 Chat Available
24/7 Chat Available
Brand new
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Respironics AF541 Under-the-Nose NIV Mask Cushion
£14.99
This item
This is the under-the-nose NIV Mask cushion for the Philips Respironics AF541 non-invasive ventilation mask. It seals beneath the nostrils and around the mouth instead of across the bridge of the nose, which is how the AF541 offloads pressure from the site where NIV skin breakdown most often starts.
Supplied new in extra small, A, B and C. The cushion pushes straight onto the AF541 mask frame and is interchangeable with the over-the-nose cushion on the same mask, so a patient can be rotated between the two seals without changing mask system. The mask, elbow and headgear are ordered separately.
Check before the mask is used on a patient
Facial pressure injury is the most common complication of non-invasive ventilation, and the nasal bridge is where it happens. The skin there is thin and sits directly over bone, a conventional oro-nasal mask places its firmest seal exactly across it, and every leak invites another turn on the headgear. In a patient who cannot reposition themselves and needs continuous ventilation, damage can appear within a day, at which point the options narrow: the patient still needs ventilating and the mask still needs to seal.
The under-the-nose cushion changes where the load sits. It closes below the nostrils and around the mouth, leaving the bridge uncovered, and Philips makes the two cushion types interchangeable on the same mask frame precisely so they can be alternated. Rotating between seals offloads and redistributes pressure, which is the recognised way to reduce skin breakdown over a long period of ventilation, and it means a unit does not have to stock two mask systems to do it. The clearer field of view is a secondary benefit that matters more than it sounds for a conscious, frightened patient.
Two limits are worth stating. This is a cushion, not a mask: it fits the AF541 frame and nothing else, so a department without AF541 masks in stock cannot use it. And it is not an answer to skin damage on its own. Pressure moves to the upper lip, cheeks and chin, so inspection continues at the new contact points, and where a bridge lesion already exists the cushion is one part of a plan alongside dressings, rotation and time off the mask.
| Elbow | Used with |
|---|---|
| Entrainment elbow, Leak 1 | Anti-asphyxia valve, for dedicated non-invasive ventilators on single limb circuits |
| Entrainment elbow, Leak 2 | Anti-asphyxia valve with intentional leak ports, for dedicated non-invasive ventilators on single limb circuits |
| Standard elbow | Ventilators with an integrated safety valve system, on dual limb circuits |
| Bronchoscopy elbow | Airway access during bronchoscopy, on masks using the click-style 22 mm elbow design |
All AF541 click-style elbows include a nebulising port. Elbows are ordered separately and are not supplied with this cushion.
Specification limited to what is confirmed
| Task | When |
|---|---|
| Inspect the cushion for splits, hardening or distortion before fitting | Every use |
| Inspect the skin at the upper lip, cheeks and chin | To local pressure ulcer prevention policy |
| Rotate between under-the-nose and over-the-nose seals to redistribute pressure | To the clinical plan for the patient |
| Clean or reprocess strictly to the AF541 instructions for use | To local decontamination policy |
| Discard the cushion | At the end of that patient's use, or sooner if damaged. Single patient use |
Cleaning, reprocessing and use limits follow the manufacturer's instructions for use and the receiving organisation's decontamination policy.
Specifications can change without notice. Ask us for the current technical file.
Further documentation is available on request.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article