Please check the bed dimensions shown on the product page and measure your front door, hallways, stairways and room doorway before ordering. The dimensions provided are approximate and may vary slightly between models. We strongly recommend allowing extra clearance beyond the stated measurements to ensure the bed can be delivered and moved into the room safely.
Ground floor delivery only
Beds are delivered fully assembled to the ground floor only. Upper floor or room placement is not included.
Returns cost the original delivery fee
If the bed cannot fit into your home, return shipping is at your expense and the original delivery fee is non-refundable.
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Sidhil Innov8 iQ Electric Hospital Bed with Devilbiss Drive Mattress with Pump (Like New)
£999.99
This item
Arjo Huntleigh Maxi Move III Patient Hoist with Battery
£300.00
The Sidhil Innov8 iQ is a four section electric profiling ward bed built for acute wards, specialist areas and high dependency use in coronary and high dependency units. It is made in Halifax by the only remaining volume manufacturer of hospital beds in the United Kingdom, which matters on a used bed because spares and service support remain available rather than becoming an obsolete part hunt. The mattress platform runs from 340 mm to 750 mm, so a patient can step off at a low height and a clinician can work at their own. Safe working load is 255 kg with a maximum patient weight of 190 kg. Supplied here with a dynamic alternating pressure mattress and its pump.
| Item | Detail | Condition |
|---|---|---|
| Innov8 iQ bed | Four section electric profiling ward bed with removable mattress platform panels | USED |
| Side rails | Cantilever folding side rails as fitted | USED |
| Bed ends | Removable head and foot panels | USED |
| Handsets | Carer handset and patient handset | USED |
| Dynamic mattress | Alternating pressure mattress | USED |
| Mattress pump | Pump unit for the dynamic mattress | USED |
| Mains lead | Coiled mains cable for the bed | USED |
| Item | Detail | Status |
|---|---|---|
| Lifting pole | Patient lifting pole, corner socket accessory | SOLD SEPARATELY |
| IV pole | Drip pole, corner socket accessory | SOLD SEPARATELY |
| Oxygen cylinder carrier | Corner socket accessory | SOLD SEPARATELY |
| Traction frames | Balkan beam and foot end traction | SOLD SEPARATELY |
| Foam mattress | Static foam surface where a dynamic mattress is not required | SOLD SEPARATELY |
| Mattress extension block | Required whenever the platform extension is in use | SOLD SEPARATELY |
| Service and commissioning | Engineer inspection and electrical safety test | SOLD SEPARATELY |
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service is not included unless this listing states that the unit has been serviced. The manufacturer specifies servicing at least once yearly, and planned maintenance and periodic electrical safety testing remain with the operating organisation once the bed is in service.
Side rails, mattress fit and entrapment risk
Side rails only reduce risk when rail, frame and mattress are dimensionally compatible, and the Innov8 iQ has two rail types with different mattress limits. The standard three bar cantilever rail takes a mattress up to 152 mm thick. The high four bar cantilever rail takes up to 279 mm. Fitting a mattress deeper than the rail allows reduces the effective rail height and opens gaps a patient can become trapped in, and an overlay used on top of a foam mattress usually means a thinner foam mattress is needed to keep within the limit. Check the effective rail height above the compressed mattress surface and check every gap against current national guidance on the safe use of bed rails, and reassess whenever the surface changes. The manufacturer states that only Innov8 iQ side rails should be used with this bed, and that these rails are not intended for use with children.
iQ Contour. When the backrest flattens, the leg section lowers in small steps rather than all at once. That keeps the patient in position on the mattress instead of letting them slide down the bed, which is what generates shear at the sacrum and drives pressure damage. It is the single most useful thing on the bed and it happens without anyone pressing anything extra.
Auto regressing backrest. The deck moves as the backrest rises rather than dragging the patient up the bed, reducing shear and abdominal compression.
Cardiac chair. Pressing auto contour and tilt within five seconds of each other profiles the bed into a seated position with foot down tilt, so a patient can sit properly without leaving the bed.
Two handsets with lockout. The carer handset controls everything and can lower the platform to 340 mm. The patient handset is deliberately limited to 420 mm and above, so an unsupervised patient cannot put the bed into the low zone, and any function locked out on the carer handset is locked out on theirs.
Electrical CPR. One button levels, flattens and lowers the platform, then drives it to maximum height for chest compressions, overriding any locked out functions. Manual CPR handles on both sides drop the backrest faster still.
| Manufacturer | Sidhil, Halifax |
| Model | Innov8 iQ general ward bed |
| Type | Four section electric profiling hospital bed |
| Safe working load | 255 kg, patient plus mattress plus accessories |
| Maximum patient weight | 190 kg |
| Overall length | 2280 mm |
| Integral length extension | 200 mm |
| Overall width | 1030 mm |
| Mattress platform height | 340 to 750 mm |
| Patient handset height range | 420 to 750 mm |
| Mattress platform length | 2000 mm |
| Mattress platform width | 880 mm |
| Under bed clearance | 150 mm with the platform at 420 mm, 80 mm at 340 mm |
| Backrest angle | 0 to 70 degrees |
| Thigh section angle | 0 to 35 degrees |
| Foot section angle | 0 to 21 degrees |
| Head down tilt | 0 to 13 degrees |
| Foot down tilt | 0 to 13 degrees |
| Mattress length | 2000 mm maximum |
| Mattress width | 864 mm recommended, 880 mm maximum |
| Mattress thickness | 152 mm with standard side rails, 279 mm with high side rails |
| Mattress weight | 15 kg maximum |
| Bed weight, frame only | 95 kg |
| Bed weight, complete with standard rails | 130 kg |
| Bed weight, complete with high rails | 134 kg |
| Linen shelf load | 20 kg maximum |
| Power supply | 230 V, plus or minus 10 per cent, 50 to 60 Hz, 2 A |
| Duty cycle | 10 per cent, 2 minutes of continuous use followed by 18 minutes at rest |
| Electrical classification | Class 1, Type B applied parts |
| Ingress protection | IPX4 |
| Standards | IEC 60601-1:2005, IEC 60601-2-52:2009, IEC 60601-1-2:2007 |
| Servicing | At least once yearly per the manufacturer |
| Condition | Pre-owned, powers up |
Configuration and mattress details
The Innov8 iQ was supplied with a choice of standard or high cantilever side rails, and the rail fitted determines the maximum mattress thickness. The rail type on this unit, and the model of the dynamic mattress and pump supplied with it, are not stated here pending confirmation against the item, and should not be assumed from the description above. Ask before ordering if either is needed, particularly where a specific mattress depth or pump specification is required.
Hoist clearance
Under bed clearance is 150 mm with the platform at 420 mm and 80 mm at the minimum height of 340 mm. Where a mobile hoist is used with the bed, the manufacturer warns that hoist legs higher than 75 mm risk collision when the bed is operated in the low zone. Check the hoist leg height against the clearance before the bed enters service in a room where hoisting takes place.
Delivery and access
| Component | Action | Interval |
|---|---|---|
| Side rails | Check the release plunger engages, the rail locks upright, and gaps against the mattress in use | Before each use |
| Brakes and castors | Push test with the brake bar down and confirm the bed does not move, then check tracking runs straight | Weekly |
| Profiling functions | Cycle height, backrest, knee break, tilt and auto contour through full travel on both handsets | Weekly |
| CPR release | Confirm both manual handles drop the backrest and the electrical CPR function operates | Weekly |
| Battery backup | Confirm the bed operates on battery, and keep it on mains between uses | Monthly |
| Mattress and pump | Decontaminate per local policy, inspect the cover for rips and seam failure, confirm the alternating cycle runs | Between patients |
| Bed extension | Extend and retract, confirming it locks in both positions and that the mattress extension block is fitted when extended | Monthly |
| Frame and fixings | Inspect welds and paint for cracks, and check all nuts, bolts and fasteners are tight | Monthly |
| Engineer service and electrical safety test | Full service per the manufacturer schedule | At least yearly |
The above is general guidance. The manufacturer instructions for use and the operating organisation's decontamination and maintenance policy take precedence. The bed should be withdrawn from service if it shows damage or does not perform as intended, until it has been repaired and determined fit for use.
UK mainland: Orders placed Monday to Friday are dispatched within 2 working days from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland and islands: standard delivery takes 5-10 working days.
Europe, USA and Canada: delivery typically takes 10-21 working days.
Other international destinations: delivery usually takes 10- 21 working days.
Orders shipped outside the United Kingdom may attract import duty and local tax, which are charged by the destination country and are the buyer's responsibility.
SelfiMed offers a 30-day change-of-mind return policy on eligible items. To request a return, please contact us within 30 days of delivery. Items returned under this policy must be in the same condition as received and suitable for resale.
Please note that brand new items must remain unopened, unused and in their original packaging to be eligible for return. Once a new item has been opened or used, it may no longer qualify for return as new, and any accepted return may be subject to restocking fees.
For hygiene reasons, opened CPAP masks, CPAP parts and CPAP accessories, including tubing, filters and humidifier chambers, cannot be returned.
Return shipping costs are the responsibility of the customer.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Specifications and compatibility are given in good faith and can change without notice.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article