24/7 Chat Available
24/7 Chat Available
Before You Order This Bed
Please read and confirm before adding to cart
Measure your access points first
Please check the bed dimensions shown on the product page and measure your front door, hallways, stairways and room doorway before ordering. The dimensions provided are approximate and may vary slightly between models. We strongly recommend allowing extra clearance beyond the stated measurements to ensure the bed can be delivered and moved into the room safely.
Ground floor delivery only
Beds are delivered fully assembled to the ground floor only. Upper floor or room placement is not included.
Returns cost the original delivery fee
If the bed cannot fit into your home, return shipping is at your expense and the original delivery fee is non-refundable.
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Hill-Rom AvantGuard Electric Hospital Bed with Mattress
£799.99
This item
The Hill-Rom AvantGuard AVG1200 Electric Hospital Bed (model LI158Bx/1200) is a premium electric profiling bed designed to deliver maximum patient safety, comfort, and caregiver efficiency. Suitable for acute wards, surgical recovery, and general medical use, it offers fully motorised head, back, thigh, and height adjustments with Trendelenburg and Reverse Trendelenburg positioning for advanced clinical flexibility.
This electric hospital bed features the intuitive EasyChair® Mode, allowing one-touch transition to a seated recovery position. Dual pendant controls, side panels, and an optional arm-mounted controller offer full control to both patient and caregiver. With battery backup, central brake-and-steer system, and removable head/foot boards, the Hill-Rom AVG1200 combines safety, manoeuvrability, and reliability—ideal for modern acute-care environments.
Fully motorised profiling for precise comfort and safe handling
Trendelenburg & Reverse Trendelenburg tilt functions
EasyChair® Mode for one-touch seated positioning
Adjustable height (40–85 cm) to reduce falls risk
Emergency CPR release lever for rapid flattening
Dual pendant, nurse-side, and optional arm controls
Function lockout to prevent misuse
Central brake and steer system for safety
Removable head and foot boards for emergency access
Technical Specifications
| Feature | Details |
|---|---|
| Sleep Surface | 90 × 200 cm |
| Height Range | 40–85 cm (model dependent) |
| Trendelenburg Angle | Electrically controlled |
| Control System | Pendant, side panel, optional arm mount |
| Brake System | Centralised with steer assist |
| Power Supply | AC mains + battery backup |
| Side Rails | TotalGuard™ or metal rails |
| EasyChair® | Yes |
| Weight Capacity | Model dependent |
| Castors | 125–150 mm |
Optional Accessories
MobiBar® egress handle
IV pole & oxygen holder
Pressure-relief mattress
Accessory bar & drainage hooks
Patient helper arms
Ideal For
Acute hospital wards
Post-operative and recovery units
General medical and surgical floors
Hospices and high-dependency units
Long-term and elderly care settings
UK mainland: Orders placed Monday to Friday are dispatched within 2 working days from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland and islands: standard delivery takes 5-10 working days.
Europe, USA and Canada: delivery typically takes 10-21 working days.
Other international destinations: delivery usually takes 10- 21 working days.
Orders shipped outside the United Kingdom may attract import duty and local tax, which are charged by the destination country and are the buyer's responsibility.
SelfiMed offers a 30-day change-of-mind return policy on eligible items. To request a return, please contact us within 30 days of delivery. Items returned under this policy must be in the same condition as received and suitable for resale.
Please note that brand new items must remain unopened, unused and in their original packaging to be eligible for return. Once a new item has been opened or used, it may no longer qualify for return as new, and any accepted return may be subject to restocking fees.
For hygiene reasons, opened CPAP masks, CPAP parts and CPAP accessories, including tubing, filters and humidifier chambers, cannot be returned.
Return shipping costs are the responsibility of the customer.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Specifications and compatibility are given in good faith and can change without notice.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article