Huntleigh Nimbus 3 Inflatable Mattress With Pump
£149.99
This item
Hill-Rom ClinActiv Bag
£21.99
Hill-Rom Total Care Duo 2 Electric Critical Care Bed with Hospital Mattress
£1,299.99
The Huntleigh Nimbus 3 is a dynamic mattress replacement system for the prevention, treatment and management of pressure ulcers. Used across hospital, nursing home and home care settings for decades, it replaces the standard mattress on hospital and domestic beds, and the bed can still be profiled and adjusted with the mattress in place.
The Auto-Matt sensor pad continually adjusts cell pressures to optimal levels according to the patient's size, weight and position, with no manual setup weights to enter. Dedicated Heelguard cells provide maximum pressure redistribution under the vulnerable heel area, the anti-sink torso section maintains support, and a quick-release CPR control allows rapid deflation in an emergency. This system is supplied pre-owned with the mattress, pump and connecting tubeset.
| Item | Qty | Condition |
|---|---|---|
| Nimbus 3 alternating pressure mattress with cover and CPR control | 1 | Used |
| Nimbus 3 pump | 1 | Used |
| Connecting tubeset | 1 | Used |
| Manufacturer | Huntleigh Healthcare (Arjo) |
|---|---|
| Model | Nimbus 3 |
| Condition | Pre-owned |
| Type | Dynamic alternating pressure mattress replacement system |
| Maximum patient weight | 250 kg (39 st) |
| Mattress dimensions | 2085 x 890 x 215 mm (standard width) |
| Mattress weight | 15.5 kg |
| Cell material | Polyurethane |
| Pump dimensions | 508 x 220 x 100 mm |
| Pump weight | 5.7 kg |
| Operating cycle | 10 minutes |
| Power supply | 230 VAC, 50 Hz, 35 VA |
| Safety classification | Class II, Type BF, IP21 |
Orders shipped outside the United Kingdom may attract import duty and local tax, which are charged by the destination country and are the buyer's responsibility.
SelfiMed offers a 30-day change-of-mind return policy on eligible items. To request a return, please contact us within 30 days of delivery. Items returned under this policy must be in the same condition as received and suitable for resale.
Please note that brand new items must remain unopened, unused and in their original packaging to be eligible for return. Once a new item has been opened or used, it may no longer qualify for return as new, and any accepted return may be subject to restocking fees.
For hygiene reasons, opened CPAP masks, CPAP parts and CPAP accessories, including tubing, filters and humidifier chambers, cannot be returned.
Return shipping costs are the responsibility of the customer.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
SelfiMed Ltd, trading as SelfiMed UK, supplies medical equipment, replacement parts and accessories but does not provide medical advice, diagnosis or treatment. Customers are responsible for ensuring that they are legally authorised to purchase and use any equipment supplied and for complying with all applicable regulations in their country. Certain medical devices may require a valid prescription or clinical directive before dispatch. Components, accessories and kits are supplied as replacement or accessory items unless expressly stated otherwise, and correct assembly, calibration, commissioning and application remain the responsibility of the user or an appropriately qualified professional.
All equipment must be used, maintained and cleaned in accordance with the manufacturer’s instructions. SelfiMed UK accepts no liability for misuse, incorrect assembly, mishandling, unauthorised modification or use outside the manufacturer’s intended purpose, and does not guarantee suitability for any particular clinical outcome unless confirmed in writing. Pre-owned or refurbished equipment should not be used for emergency or critical care without appropriate professional oversight and commissioning. Customers should obtain advice from a qualified healthcare professional or medical device technician where required and assume responsibility for the lawful, safe and appropriate use of the products purchased.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article