Skip to content
BLACK FRIDAYUp to −80% on selected items · −10% on everything else with BLACKFRIDAY10Ends Mon 30 Nov
Free UK mainland delivery over £300 · large items £1,000+
Next-day dispatch on orders placed before 1pm Monday–Friday
Worldwide delivery with trusted carriers — tracked and insured
VAT Relief available for eligible patients — save 20% on your order
Before you buy
Returns: 30 days change of mind on UK orders.
Warranty: 90 days (SelfiMed)
In the box: Welch Allyn CP 150 electrocardiograph, 10 lead patient cable.

Warranty

The warranty depends on the item's condition. This item's row is highlighted.

ItemWarrantyCovers
Brand new, other brandsManufacturer'sAs set by the maker
Brand new, Alvera6 monthsFaults in materials or manufacture
New (other)12 monthsFaults in normal use
Like new and refurbished6 monthsFaults in normal use
Pre-owned90 daysFaults in normal use
Missing parts or with defects30 daysFaults other than those listed on the page

Alvera items are covered by Elarix Medical, the maker of Alvera. Other conditions are covered by SelfiMed. Every warranty starts on the day of delivery.

Not covered

  • Normal wear: cushions and pillows soften and seal less well with use, and headgear stretches. This is why they are replaced on a schedule.
  • Damage from cleaning with alcohol, bleach, scented soap or a dishwasher.
  • Drops, cuts, crushing, or changes made to the product.
  • The wrong size or model ordered.

How to claim

Email info@selfimed.com with your order number and a clear photo or short video of the fault. If we ask for the item back, please clean it first.

Returns and refunds

Opened or used CPAP accessories can't be returned. Masks, cushions, nasal pillows, tubing, filters and anything that touches the airway are sealed for hygiene and cannot come back once the seal is broken, even if unused.

  • Change of mind: 30 days from delivery on UK orders. You pay the return postage.
  • Opened new items: a deduction of up to 40% may apply; from day 15 to day 30, 40%.
  • Faulty or not as described: full refund within 30 days, and we pay the return postage. After that, the warranty applies.
  • International orders: no change-of-mind returns.

Full terms: returns and warranty policy. These terms do not affect your statutory rights.

All products / Electrocardiogramme

Welch Allyn CP 150 ECG Machine with 10 Lead ECG Lead

Welch AllynSKU WEL4070D
Price
£59999

−10%at checkout · BLACKFRIDAY10

Black Friday · ends Monday 30 November, 23:59

Price shown excludes VAT.

VAT relief available on this product

Eligible customers can claim VAT relief on this product at checkout.

Quantity
Unit price£599.99
Total£599.99

✓ FREE UK mainland delivery on this item

Prefer a quote?
Key attributes
Brand
Welch Allyn
Category
Electrocardiogramme
SKU
WEL4070D
Options
2 to choose from

Welch Allyn CP 150 Resting Electrocardiograph with 10 Lead Patient Cable, Pre-Owned

The Welch Allyn CP 150 is a resting electrocardiograph for primary care, occupational health and outpatient clinics. It records a diagnostic quality trace, previews it on a 7 inch colour touchscreen before anything is printed, and produces a full size printout on Z-fold thermal paper. It is supplied here with the 10 lead patient cable.

The naming is worth clearing up, because it causes more ordering errors than any other detail on an ECG machine. A 10 lead cable has ten lead wires and ten electrodes on the patient: one on each limb and six across the chest. Those ten electrodes produce the twelve views a clinician reads, so a 10 lead cable and a 12 lead ECG are the same thing described from different ends. A machine without its cable records nothing at all, which is why the cable is the accessory that decides whether a used ECG machine is usable on arrival.

In practice the CP 150 earns its place on three things. Instant-on means a trace can be taken the moment a patient is on the couch rather than after a boot sequence. The preview before print means a poor trace is spotted and repeated on screen rather than on paper, which on a busy clinic day is a real saving in both paper and time. And the lead quality monitoring flags a poor electrode connection before the recording, which is the difference between a clean trace and a repeat.

Connectivity is by USB and Ethernet as standard, with a CardioPerfect workstation route for storing and reviewing tests on a PC, and at least 100 tests held in the device itself. Battery operation gives around eight hours or roughly 250 recordings per charge, so the machine travels to the patient rather than the other way round.

References

Item Detail
Manufacturer Welch Allyn, part of Hillrom and Baxter
Model CP 150 resting electrocardiograph
Patient cable 10 lead, producing a 12 lead ECG
Variants in the range With or without MEANS interpretation, with or without spirometry, with or without wireless

Features

  • 7 inch colour touchscreenat 800 by 480, used for patient data entry and for previewing the trace, which removes the keypad fumbling that slows older machines.
  • Preview before print, in 3, 6 or full 12 lead views, so a poor recording is caught on screen and repeated rather than printed and thrown away.
  • Instant-on, so a trace can be started the moment the patient is ready rather than after a boot sequence.
  • Lead quality monitoring, checking each electrode connection and prompting before the recording, which is where most repeat traces come from.
  • Full size printout on Z-fold thermal paper, 21 by 28 cm, which is the format most UK practices file and post.
  • At least 100 tests stored in the device, with export to a USB memory stick or to a CardioPerfect workstation.
  • Standard and Cabrera lead configurations, so the output matches local reporting convention.
  • Advanced filtering, with a 35 Hz muscle tremor filter, a 0.5 Hz high performance baseline filter and selectable 50 or 60 Hz mains interference rejection.
  • Common mode rejection above 80 dB, which is what keeps a trace clean in a room full of other electrical equipment.
  • Battery operation, around 8 hours of continuous use or 250 recordings per charge, recharging to most of its capacity in about 4 hours.
  • USB and Ethernet connectivityas standard, with one USB client port and four USB host ports.

Important notice

Verify before clinical use.This is a diagnostic measuring device. On receipt, confirm the machine records a clean trace on all twelve leads using a simulator or a known good subject, check the printout against the on-screen trace, and confirm the date, time and paper speed settings are correct before any recording is filed in a patient record. Electrical safety testing, including patient applied part leakage, is carried out as for any pre-owned mains powered medical device. No calibration certificate accompanies this unit, and ongoing maintenance and periodic testing sit with the operating organisation under PUWER 1998.

Interpretation is decision support, not a diagnosis.Where a machine is fitted with the MEANS interpretation option, the statements it prints are a second opinion generated by an algorithm and are always overread by a clinician competent to report an ECG. An uninterpreted trace is not a normal trace, and an interpreted one is not a confirmed diagnosis.

Cables, electrodes and hygiene.Check the patient cable and every lead wire for damaged insulation, bent pins and cracked connectors before each use, since a damaged cable produces artefact that can be mistaken for pathology. Electrodes are single use and are never reapplied between patients. Lead wire colour coding differs between the AHA and IEC standards, so confirm which standard the supplied cable follows before it is used by staff trained on the other, and clean the cable and the machine to local decontamination policy between patients.

Reviews

Written by people who bought from us.

Verified by Reviewit
Our reviews on Reviewit
Free Shipping £300. UK Mainland & selected UK islands £300 Free Shipping UK Mainland & selected UK islands

UK Mainland Next Day Delivery

Order by 1pm, Mon-Fri. Delivery available Mon-Sat.

VAT Relief Available

For eligible patients & conditions