Skip to content
BLACK FRIDAYUp to −80% on selected items · −10% on everything else with BLACKFRIDAY10Ends Mon 30 Nov
Free UK mainland delivery over £300 · large items £1,000+
Next-day dispatch on orders placed before 1pm Monday–Friday
Worldwide delivery with trusted carriers — tracked and insured
VAT Relief available for eligible patients — save 20% on your order
Before you buy
Returns: 30 days change of mind on UK orders.
Warranty: 90 days (SelfiMed)
In the box: Power-PRO TL stretcher, Compatible battery and 3 more.

Warranty

The warranty depends on the item's condition. This item's row is highlighted.

ItemWarrantyCovers
Brand new, other brandsManufacturer'sAs set by the maker
Brand new, Alvera6 monthsFaults in materials or manufacture
New (other)12 monthsFaults in normal use
Like new and refurbished6 monthsFaults in normal use
Pre-owned90 daysFaults in normal use
Missing parts or with defects30 daysFaults other than those listed on the page

Alvera items are covered by Elarix Medical, the maker of Alvera. Other conditions are covered by SelfiMed. Every warranty starts on the day of delivery.

Not covered

  • Normal wear: cushions and pillows soften and seal less well with use, and headgear stretches. This is why they are replaced on a schedule.
  • Damage from cleaning with alcohol, bleach, scented soap or a dishwasher.
  • Drops, cuts, crushing, or changes made to the product.
  • The wrong size or model ordered.

How to claim

Email info@selfimed.com with your order number and a clear photo or short video of the fault. If we ask for the item back, please clean it first.

Returns and refunds

Opened or used CPAP accessories can't be returned. Masks, cushions, nasal pillows, tubing, filters and anything that touches the airway are sealed for hygiene and cannot come back once the seal is broken, even if unused.

  • Change of mind: 30 days from delivery on UK orders. You pay the return postage.
  • Opened new items: a deduction of up to 40% may apply; from day 15 to day 30, 40%.
  • Faulty or not as described: full refund within 30 days, and we pay the return postage. After that, the warranty applies.
  • International orders: no change-of-mind returns.

Full terms: returns and warranty policy. These terms do not affect your statutory rights.

All products / Ambulance stretcher

Stryker 6550 Power-Pro TL Ambulance Stretcher with Compatible Battery & Charger

StrykerSKU STA1475N05
Price
£92999£1,999.99Save 53%

−10%at checkout · BLACKFRIDAY10

Black Friday · ends Monday 30 November, 23:59

Price shown excludes VAT.

VAT relief available on this product

Eligible customers can claim VAT relief on this product at checkout.

Hours Used 10.0 - 12 Hours
Quantity
Unit price£929.99
Total£929.99
You save£0.00

Free UK mainland delivery on orders over £1,000

Prefer a quote?

Frequently bought together

Add the whole set in one go.

Stryker Power Stretcher Push & Pull Pole £99.99 £109.99
Emergency Lifting Sheet Max Load 150kg £62.69 £68.96
Duo Patient Transfer Slide £38.49 £42.34
Total for the set £0.00

Key attributes
Brand
Stryker
Category
Ambulance stretcher
SKU
STA1475N05
Options
6 to choose from

Stryker 6550 Power-PRO TL Electric Ambulance Stretcher, Pre-Owned, with Compatible Battery, Charger, Mattress and Restraint Straps

The Stryker 6550 Power-PRO TL is an electrically operated ambulance stretcher built to take the manual lift out of patient loading and unloading. Battery driven hydraulics raise and lower the litter under control, which removes the repeated heavy lifting that drives cumulative back injury in ambulance crews. Rated capacity is 318 kg. Retractable head and foot sections shorten the cot for storage and confined spaces, the pneumatic backrest adjusts across a 0 to 73 degree range, and foot end controls keep operation within reach during a transfer. This unit is pre-owned and is supplied with a compatible battery, a compatible charger, a mattress and restraint straps.

Stryker 6550 Power-PRO TL electric ambulance stretcher with powered hydraulic lift

Mandatory before any use with a patient

  • This stretcher is lifting equipment used to lift persons. In Great Britain it falls under LOLER 1998 and requires a thorough examination by a competent person at least every six months, with a current report of thorough examination held before the equipment enters service.
  • A qualified service engineer must inspect, function test and load test the unit before it carries a patient, covering the hydraulic lift, the manual override, the wheel locks, the side rails, the backrest cylinder and the retractable head and foot sections.
  • Operators must be trained on this cot and on the fastening system fitted to the vehicle before use on the road.
  • The 318 kg rating applies to the stretcher in serviceable condition. Any lower limit set by the vehicle fastener, the loading system or the crew's safe system of work takes precedence.
  • Inspect the restraint straps and mattress cover before service. Webbing that is frayed, a buckle that does not latch cleanly, or a cover with rips or tears should be renewed before the cot is used.

Compatible battery and charger, not original manufacturer parts

The battery and charger supplied with this unit are third party compatible items rather than original parts. They are pre-owned, so usable capacity and the number of lift cycles available from a full charge cannot be stated and must be assessed by the commissioning engineer. Where a service pattern depends on guaranteed runtime, an original battery should be fitted and a second pack held on rotation. Charge only with a charger rated for the battery in use, and do not mix charging hardware across different battery types.

Key features

Battery powered hydraulic lift raising and lowering the litter under control, so the crew guides the load rather than lifting it.
318 kg maximum weight capacity and the same figure for maximum unassisted lift, within the limits of the vehicle and fastening system.
Pneumatic backrest adjusting from flat through to seated across a 0 to 73 degree range.
Retractable head and foot sections shortening the cot to 139.7 cm for corridors, lifts and loading, extending to 194.3 cm for transport.
Foot end controls placing operation where the crew stands during loading and unloading.
Class II double insulated electrical construction on the powered system.
58.4 cm width, a standard cot footprint for ambulance saloons and hospital corridors.
Mattress and restraint straps supplied, so the cot arrives with the patient surface and restraint set rather than as a bare frame.
Established parts and accessory ecosystem across the Power-PRO platform, which keeps a used cot serviceable in a mixed fleet.

Suited to

  • Ambulance and emergency services
  • Hospital emergency departments
  • Inter-facility patient transfers
  • Event medical and private ambulance operators

Delivery and access

  • This is a large, heavy item measuring 194.3 cm in overall length. Measure every access point on the route, including doorways, corridor turns, lift dimensions and loading bay height, before ordering.
  • Dimensions given are approximate and should be treated as a guide for access planning rather than an exact figure.
  • Delivery is to ground floor only, kerbside or first accessible doorway. Two people should be available to receive and move the item.
  • Return shipping is at the buyer's expense and any delivery fee paid is non-refundable.

Routine care guidance

Component Action Interval
Battery Check charge state, return to charge after use, inspect contacts for corrosion Every shift
Wheel locks and castors Check locks hold, clear debris and thread from the castor spindles Every shift
Restraints Check webbing for fraying and confirm every buckle latches and releases cleanly Every shift
Lift and backrest Cycle through full travel, confirm the backrest cylinder holds and the manual override operates Weekly
Mattress Decontaminate per local policy, inspect the cover for rips and seam failure After each patient
Frame and fixings Inspect for cracks, deformation, loose fasteners and hydraulic leaks Monthly
Thorough examination Formal examination by a competent person under LOLER 1998 At least every six months

The above is general guidance. The manufacturer instructions for use and the operating service's own decontamination and maintenance policy take precedence. Any unit showing a fault should be taken out of service until it has been repaired and re-tested.