Skip to content
VAT Relief available for eligible patients — save 20% on your order
Next-day dispatch on orders placed before 1pm Monday–Friday
Worldwide delivery with trusted carriers — tracked and insured
Free UK delivery over £300 · large items £1,000+
Brand
Philips Genuine Parts
  • UK stock, dispatched from Leeds
All products / CPAP Mask Accessories

Frame for DreamWear CPAP Masks

PhilipsSKU FRC2198L02
Price
£4699£120.99Save 61%

Price shown excludes VAT.

VAT relief available on this product

Eligible customers can claim VAT relief on this product at checkout.

Size Large
Quantity
Unit price£46.99
Total£46.99
You save£0.00

Prefer a quote?

Frequently bought together

Add the whole set in one go.

Frame for DreamWear CPAP Masks £46.99 This item
Elbow for DreamWear CPAP Masks £14.99 £19.99
Total for the set £0.00

Key attributes
Brand
Philips
Category
CPAP Mask Accessories
SKU
FRC2198L02
Options
4 to choose from

Philips Respironics DreamWear Mask Frame, Genuine Spare Part

The DreamWear frame is the hollow silicone body of the mask. Air arrives from the tube at the top of the head, travels down two soft channels either side of the face and meets at the cushion under the nose, which is why there is nothing across the bridge of the nose and nothing in the field of view.

This is a genuine Philips Respironics spare part, supplied on its own in small, medium or large. Any frame size works with any DreamWear cushion, so a frame can be renewed without changing the rest of the mask.

Before fitting the frame

  • The frame is part of the air path. It is assembled with a genuine DreamWear cushion and elbow, following the mask user guide, and is not adapted to parts from another mask system.
  • The vent that clears exhaled air sits in the elbow, not the frame. Never block, tape over or modify any vent opening.
  • Frame size and cushion size are separate choices. Changing frame size does not change the cushion required, and the two are not fitted by matching the labels.
  • Where mask leak, pressure marks or discomfort persist after the frame is renewed, the fit is reviewed by the clinical service rather than corrected by tightening the headgear.

Why the frame is the part that wears

On most masks the frame is rigid plastic and the cushion does the work. DreamWear is built the other way round: the frame is soft silicone and hollow, so it is simultaneously the structure that holds the mask on the face and the duct that carries the air. That design is what gets the tube off the face and up to the crown of the head, and it is why the mask suits people who sleep on their side or their front, or who want to read or wear glasses in bed with the mask on.

It also explains why the frame is a wearing part rather than a permanent one. Silicone in daily contact with skin oils gradually loses the slight tackiness that holds a seal, and the arms lose a little of their spring, so the mask drifts and the headgear ends up being tightened to compensate. Tightening is the wrong fix: it presses the cushion harder against the face, marks the skin and often makes the leak worse. Philips sets the renewal interval at three months for that reason, and a frame reaching that point is a cheaper answer than a whole new mask.

Two things are worth knowing before ordering. The hollow arms mean that if one side is compressed against a pillow, the air redirects through the other, so side sleeping does not interrupt therapy, but it also means a split or a crack anywhere in the frame is a leak in the air path rather than a cosmetic fault. And the frame is not a universal part: it fits the DreamWear family only. Anyone with a different Philips mask, or a mask from another manufacturer, needs that manufacturer's own frame.

Key features

Hollow silicone frame, carrying air down both sides of the face to the cushion, so the mask body is the duct and there is no tube crossing the field of view.
Tube connection at the crown of the head, keeping the hose clear of the face and off the pillow, which is what allows side and front sleeping without the tube being pulled.
Dual channel airflow, redirecting through the opposite arm when one side is compressed against a pillow, so therapy continues through a position change rather than pausing.
Soft frame with minimal contact area, following the contours of the face rather than clamping across them, which reduces the pressure points that show as marks in the morning.
Works with every DreamWear cushion type, covering nasal, gel nasal pillow, silicone nasal pillow and full face, so one frame serves whichever cushion the wearer settles on.
Three sizes, small, medium and large, with medium fitting most adults. Sizing follows the distance from the crown of the head to the nose rather than face width.
Assembles without tools, pushing together with the cushion, elbow and headgear, so a frame is renewed in under a minute at the bedside.
Genuine Philips Respironics part, holding the tolerances the cushion seal and the vent flow were designed around, which a copied frame cannot be relied on to do.

Specification limited to what is confirmed

  • Frame length figures quoted in an earlier description have been left out. They were given in inches only and do not correspond to the physical size of any DreamWear frame, so they would have misled anyone sizing from them.
  • Sizing is done with the manufacturer's DreamWear sizing gauge, or by matching the size marked on an existing frame. The size is printed on the frame itself, next to the connector.
  • Part numbers above are confirmed against the pack before dispatch.

Choosing the right size

Medium fits most adults and is the size supplied in most complete DreamWear masks, so a wearer replacing a frame from a boxed mask is usually on medium unless they changed it.
The size is printed on the frame, moulded near the tube connector. Reading it off the frame already in use is quicker and more reliable than measuring.
Frame size is independent of cushion size, so a wearer using a small cushion is not necessarily on a small frame, and changing cushion type does not require a different frame.

Routine care schedule

Task Interval
Wipe the frame and cushion clean after use Daily
Wash the frame in warm water with a mild detergent, rinse and air dry away from direct sunlight Weekly
Inspect the arms and connector for splits, cracks or hardening Weekly
Renew the frame Every three months
Renew the cushion To the interval in the mask instructions, typically more often than the frame

Intervals follow manufacturer guidance and are shortened where the mask is used in a shared or institutional setting.

Reviews

Written by people who bought from us.

No reviews yet. Bought this item? Be the first to say how it went.

Every review comes from a verified buyer of this product.

Verified by Reviewit
Our reviews on Reviewit
Free Shipping £300. UK Mainland & selected UK islands £300 Free Shipping UK Mainland & selected UK islands

Global Shipping

Worldwide delivery – trusted carriers

VAT Relief Available

For eligible patients & conditions