In the box: BiPAP A40 Pro unit, Heated humidifier and 4 more.

Warranty

The warranty depends on the item's condition. This item's row is highlighted.

ItemWarrantyCovers
Brand new, other brandsManufacturer'sAs set by the maker
Brand new, Alvera6 monthsFaults in materials or manufacture
New (other)12 monthsFaults in normal use
Like new and refurbished6 monthsFaults in normal use
Pre-owned90 daysFaults in normal use
Missing parts or with defects30 daysFaults other than those listed on the page

Alvera items are covered by Elarix Medical, the maker of Alvera. Other conditions are covered by SelfiMed. Every warranty starts on the day of delivery.

Not covered

  • Normal wear: cushions and pillows soften and seal less well with use, and headgear stretches. This is why they are replaced on a schedule.
  • Damage from cleaning with alcohol, bleach, scented soap or a dishwasher.
  • Drops, cuts, crushing, or changes made to the product.
  • The wrong size or model ordered.

How to claim

Email info@selfimed.com with your order number and a clear photo or short video of the fault. If we ask for the item back, please clean it first.

Returns and refunds

Opened or used CPAP accessories can't be returned. Masks, cushions, nasal pillows, tubing, filters and anything that touches the airway are sealed for hygiene and cannot come back once the seal is broken, even if unused.

  • Change of mind: 30 days from delivery on UK orders. You pay the return postage.
  • Opened new items: a deduction of up to 40% may apply; from day 15 to day 30, 40%.
  • Faulty or not as described: full refund within 30 days, and we pay the return postage. After that, the warranty applies.
  • International orders: no change-of-mind returns.

Full terms: returns and warranty policy. These terms do not affect your statutory rights.

All products / BiPAP Machine

Philips Respironics BiPAP Machine A40 Unit with 1096770 Detachable Battery Module with Li-ion Battery

PhilipsSKU PHB205901
Price
$80200

−10%at checkout · BLACKFRIDAY10

Black Friday · ends Monday 30 November, 23:59

Quantity
Unit price$802.00
Total$802.00

Prefer a quote?

Frequently bought together

Add the whole set in one go.

Total for the set $0.00

Key attributes
Brand
Philips
Category
BiPAP Machine
SKU
PHB205901
Options
2 to choose from

BiPAP Machine Philips Respironics A40 Pro with 1096770 Battery Module and Heated Humidifier

This pre-owned BiPAP machine is a Philips Respironics BiPAP A40 Pro bi-level non-invasive ventilator built for patients with chronic and complex respiratory insufficiency. It is indicated for adult and paediatric patients above 10 kg and is used in hospitals, sleep laboratories and home ventilation programmes. This unit is supplied with the 1096770 detachable battery module and lithium-ion battery, together with the heated humidifier and water chamber.

The A40 Pro adapts therapy to changing patient conditions and delivers the lowest effective pressure while maintaining ventilation quality. AVAPS holds a target tidal volume by adjusting pressure support, AVAPS-AE additionally monitors upper airway resistance and adjusts EPAP to keep the airway patent, and Automated Airway Management supports patients with overlapping breathing syndromes. Auto-Trak synchronisation with leak compensation keeps the device responsive to weak respiratory drive, which matters for neuromuscular and hypoventilation cases.

Visual Leak gives a real-time indication of total circuit leak, which helps the clinical team resolve mask fit problems quickly. The device connects to Philips Care Orchestrator for remote therapy review and patient management. Operation is quiet at around 30 dBA and the housing is compact enough for long-term domiciliary use while retaining the performance expected in a hospital NIV service.

Mandatory before any clinical use

  • This device must be commissioned and function tested by a qualified ventilator engineer before it is used on a patient.
  • Ventilation modes, pressures, backup rate, tidal volume targets and alarm limits must be set only by or under the direction of the responsible clinician.
  • A fresh patient circuit and fresh air inlet filters are mandatory. A fresh water chamber is strongly advised for a new patient.
  • This unit is not sold for life-support ventilation. It is a non-life-support bi-level device and must not be used where uninterrupted ventilation is required to sustain life.

Key features

AVAPS volume assurance holds a target tidal volume by automatically varying pressure support, which supports carbon dioxide clearance in hypoventilation.
AVAPS-AE mode monitors upper airway resistance and adjusts EPAP to maintain a patent airway, with an automatic backup rate option that follows the spontaneous respiratory rate.
Automated Airway Management addresses overlapping breathing syndromes in bi-level patients without repeated manual retitration.
Auto-Trak synchronisation with leak compensation, including a sensitive Auto-Trak setting and a flow trigger option for weak respiratory effort.
Pressure to 40 cm H2O across a 4 to 40 cm H2O range, covering high pressure support requirements in neuromuscular and chest wall disease.
Visual Leak indication shows total circuit leak in real time so mask fit can be corrected at the bedside.
Paediatric capability down to 10 kg body weight, so the same platform covers transition and adult services.
Detachable battery module supports transfers, mobilisation and mains interruption, using the 1096770 module supplied with this unit.
Integrated humidification with a System One heated humidifier and heated tube compatibility for comfort during long overnight sessions.
Low flow oxygen entrainment of up to 15 L/min at 10 psi where supplementary oxygen is prescribed.
Comprehensive alarm set covering circuit disconnect, apnoea, low tidal volume, low minute ventilation, high respiratory rate and low SpO2.
Care Orchestrator connectivity for remote therapy review, compliance monitoring and proactive caseload management.
Quiet and compact at approximately 30 dBA and around 2 kg, suitable for a bedside table in a domiciliary setting.

Pre-owned battery module

The lithium-ion battery supplied with this unit is pre-owned. The usable capacity of any lithium-ion cell falls with age and cycle count, so the runtime achieved will be lower than that of a fresh cell and cannot be stated for this unit. The battery must be assessed by the commissioning engineer and must not be relied upon as the sole power source for a patient. Where mains independence is clinically required, a fresh battery should be fitted before the device enters service.

Pre-owned electrical equipment

The unit has been cleaned and visually inspected. An engineer electrical safety test is recommended before clinical use, alongside the ventilator function test described above.

Supplementary oxygen safety

Where oxygen is added to the circuit, keep the device and circuit away from smoking, naked flames and any source of ignition. Do not use oil, grease or petroleum based products on or near the equipment. Use the device in a ventilated room and keep the air intake and filter area unobstructed. Oxygen flow must be set by the responsible clinician and the oxygen source must be turned off when the device is not running.

Humidifier and water chamber

Fill the chamber with distilled water only. Tap water leaves mineral deposits that damage the chamber and reduce humidifier performance. Empty and dry the chamber daily and clean it before first use in a new patient. The chamber is a consumable component and should be renewed at the interval given in the instructions for use.

Routine care guidance

Component Action Interval
Reusable foam filter Wash in warm water with mild detergent, air dry fully before refitting Weekly
Disposable ultrafine filter Fit a fresh filter, or sooner if visibly soiled Monthly
Patient circuit Clean per the circuit instructions, inspect for splits and leaks Weekly
Water chamber Empty, rinse and dry, refill with fresh distilled water Daily
Device exterior Wipe with a damp cloth, device disconnected from the mains Weekly
Mask and headgear Clean per the interface instructions Per interface guidance

Intervals above are general guidance for a single patient in a domiciliary setting. Institutional decontamination policy and the manufacturer instructions for use take precedence.