Welch Allyn Connex Spot Vital Signs Monitor on Stand with Power Supply and Accessories
£399.99
This item
The Welch Allyn Connex Spot Monitor is a spot-check vital signs device for wards, clinics and outpatient areas. This unit measures non-invasive blood pressure, oxygen saturation and pulse rate, and comes on a mobile stand with its power supply, cuff and hose, and SpO2 sensor. The Connex platform is built around workflow rather than measurement alone: readings can be captured against a patient record and sent onward, which removes the transcription step where observation errors usually enter the notes. A colour touchscreen and a rechargeable battery let the unit run through a round and return to the mains between uses.
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service and calibration are not included unless this listing states that the unit has been serviced. Verification of measurement accuracy against local policy, planned maintenance and periodic electrical safety testing remain with the operating organisation once the device is in service.
Clinical use
Configuration and modules
The Connex Spot Monitor was supplied in several configurations. Oximetry was offered with more than one technology, thermometry was an option that is not fitted to every unit, and connectivity and printer options varied. Consumables are specific to the modules fitted. No model number or module set is stated here, and none should be assumed. Ask before ordering and the configuration will be confirmed from the device information screen and the rating label, so that cuffs, sensors and probe covers can be matched correctly from the outset.
Weight not stated
The approximate 4 kg figure in circulation for this model covers different configurations and does not distinguish the monitor from the monitor plus stand. No weight is given here. If it is needed before purchase, ask and the unit will be weighed as supplied.
| Component | Action | Interval |
|---|---|---|
| Cuff and hose | Inspect for splits, kinks and leaks, wipe down per local policy | Between patients |
| SpO2 sensor | Check the emitter and detector windows are clean and the cable is undamaged | Between patients |
| Device and stand | Wipe down per local policy, check castors and stand security | Weekly |
| Battery | Return to mains after use, note any fall in runtime | After each use |
| Mains lead and plug | Inspect for damage and strain at the entry point | Weekly |
| Cuff sizing stock | Confirm the full range of cuff sizes needed for the caseload is available | Monthly |
| Accuracy verification and electrical safety test | Engineer check against a calibrated reference | Per local schedule |
The above is general guidance. The manufacturer instructions for use and the operating organisation's medical device management policy take precedence. Any device giving readings that do not fit the clinical picture should be taken out of service and verified before further use.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
September 29, 2026
A plain-language guide to the Bristol Maid Treatment Table covering construction, features, PUWER obligations and what to check when buyi...
Read Article
September 29, 2026
Key factors to assess when selecting an examination couch for podiatry, covering height range, leg rest design, SWL, upholstery condition...
Read Article
September 29, 2026
Common setup, operation and maintenance mistakes with the Linet Latera Electric Hospital bed, and clear practical guidance on how to avoi...
Read Article