Welch Allyn CP 150 ECG Machine with 10 Lead ECG Lead
ยฃ429.99
This item
The Welch Allyn CP 150 is a resting electrocardiograph for primary care, occupational health and outpatient clinics. It records a diagnostic quality trace, previews it on a 7 inch colour touchscreen before anything is printed, and produces a full size printout on Z-fold thermal paper. It is supplied here with the 10 lead patient cable.
The naming is worth clearing up, because it causes more ordering errors than any other detail on an ECG machine. A 10 lead cable has ten lead wires and ten electrodes on the patient: one on each limb and six across the chest. Those ten electrodes produce the twelve views a clinician reads, so a 10 lead cable and a 12 lead ECG are the same thing described from different ends. A machine without its cable records nothing at all, which is why the cable is the accessory that decides whether a used ECG machine is usable on arrival.
In practice the CP 150 earns its place on three things. Instant-on means a trace can be taken the moment a patient is on the couch rather than after a boot sequence. The preview before print means a poor trace is spotted and repeated on screen rather than on paper, which on a busy clinic day is a real saving in both paper and time. And the lead quality monitoring flags a poor electrode connection before the recording, which is the difference between a clean trace and a repeat.
Connectivity is by USB and Ethernet as standard, with a CardioPerfect workstation route for storing and reviewing tests on a PC, and at least 100 tests held in the device itself. Battery operation gives around eight hours or roughly 250 recordings per charge, so the machine travels to the patient rather than the other way round.
| Item | Detail |
|---|---|
| Manufacturer | Welch Allyn, part of Hillrom and Baxter |
| Model | CP 150 resting electrocardiograph |
| Patient cable | 10 lead, producing a 12 lead ECG |
| Variants in the range | With or without MEANS interpretation, with or without spirometry, with or without wireless |
Verify before clinical use.ย This is a diagnostic measuring device. On receipt, confirm the machine records a clean trace on all twelve leads using a simulator or a known good subject, check the printout against the on-screen trace, and confirm the date, time and paper speed settings are correct before any recording is filed in a patient record. Electrical safety testing, including patient applied part leakage, is carried out as for any pre-owned mains powered medical device. No calibration certificate accompanies this unit, and ongoing maintenance and periodic testing sit with the operating organisation under PUWER 1998.
Interpretation is decision support, not a diagnosis.ย Where a machine is fitted with the MEANS interpretation option, the statements it prints are a second opinion generated by an algorithm and are always overread by a clinician competent to report an ECG. An uninterpreted trace is not a normal trace, and an interpreted one is not a confirmed diagnosis. Whether this individual machine carries the interpretation option is confirmed before dispatch, since the CP 150 was sold in both configurations and the two are visually identical.
Cables, electrodes and hygiene.ย Check the patient cable and every lead wire for damaged insulation, bent pins and cracked connectors before each use, since a damaged cable produces artefact that can be mistaken for pathology. Electrodes are single use and are never reapplied between patients. Lead wire colour coding differs between the AHA and IEC standards, so confirm which standard the supplied cable follows before it is used by staff trained on the other, and clean the cable and the machine to local decontamination policy between patients.
Specifications can change without notice. Ask us for the current technical file.
Further documentation is available on request.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuardโข Universal In-Line filter, with plain fac...
Read Article