24/7 Chat Available
24/7 Chat Available
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Anetic Aid QA4 Hydraulic Transfer Trolley
£599.99
This item
The Anetic Aid QA4 is a mobile surgery system rather than a transfer trolley in the ordinary sense. A day case patient is admitted, anaesthetised, operated on, recovered and discharged on the same platform, which removes every transfer between trolley, table and bed that a conventional pathway would involve. Each of those transfers is a manual handling task, a delay, and a chance of injury to patient and staff.
This is the hydraulic version. Height is raised and lowered on a foot pump rather than by an actuator, so there is no battery to age, no charger to find and no control box to fail. For a department that wants the QA4 platform and its accessory range without the cost and the maintenance of powered functions, that is a sound trade, and it is why the hydraulic model remains in service alongside the powered one.
The platform takes the same interchangeable head and leg sections as the rest of the range, which is what adapts one trolley across general surgery, gynaecology, endoscopy, ENT, dental and ophthalmic work. Removable rotating side rails protect the patient in transport and recovery and clear entirely for surgical access. Centrally braked castors and a low rolling resistance make a loaded trolley manageable on level ground.
This unit is pre-owned. The hydraulic and powered models carry different weight limits and different height ranges, so the figures below are those the manufacturer publishes for the hydraulic model, and the label on this individual trolley governs its use.
| Item | Detail |
|---|---|
| Manufacturer | Anetic Aid Limited, United Kingdom |
| Product | QA4 Mobile Surgery System, hydraulic functions |
| Manufacturer product code | 21310 |
| Instructions for use | Document 992008 |
| Powered equivalent | QA4 Powered Mobile Surgery System, product code 21300, document 992010 |
The hydraulic model has a lower weight limit than the powered model. Anetic Aid publishes a maximum patient weight of 160 kg with a safe working load of 200 kg for the QA4 Mobile Surgery System, product code 21310, while the powered system, product code 21300, is rated at 250 kg with a safe working load of 300 kg. Those figures are not interchangeable and the higher pair must never be applied to a hydraulic trolley. The safe working load is the sum of the patient, every accessory fitted and everything carried on those accessories. Removable head sections take a maximum of 25 kg and the removable leg section a maximum of 50 kg. Confirm the figures on this individual trolley's own label before it is used, and work to those.
Inspection, testing and statutory duties. No service history, load test or certificate accompanies this trolley. A full functional check through the hydraulic range, the brakes and every latch is carried out on receipt. Where equipment used at work raises or lowers a person, the receiving organisation should confirm with its own competent person how LOLER 1998 and PUWER 1998 apply to this trolley in its intended use and at what interval, and arrange thorough examination accordingly. A hydraulic system introduces its own failure modes, so pay particular attention to any sign of fluid loss, to a platform that creeps down under load, and to a foot pump that needs more strokes than it once did.
Use limitations from the manufacturer. The trolley is not used to transport patients in a moving vehicle, and is not used outside where rough ground may damage it. Ground clearance beneath the central column is very low, so uneven surfaces and inclines cause problems. Check that nothing is stored in the base of the trolley before the patient platform is lowered. Do not apply excessive force to the steering pedal, and never stand on it, since that permanently damages the mechanism. Where a patient is positioned over a perineal cut out, their weight is offset towards the foot end and the platform behaves differently. Lower the trolley to minimum height whenever a patient is left on it, and have patients mount at the centre of the platform with weight evenly distributed.
Specifications can change without notice. Ask us for the current technical file.
Further documentation is available on request.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article