Arjo Tenor Bariatric Mobile Patient Hoist with Weighing Scale
Arjo Tenor Bariatric Mobile Patient Hoist with Integrated Weighing Scale, 320 kg Safe Working Load, Pre-Owned
The Arjo Tenor is a heavy duty mobile floor lifter built for plus-size and bariatric transfers, with a safe working load of 320 kg. That capacity places it at the top of the mobile hoist range and is the reason services keep one on the ward rather than hiring in when a bariatric admission arrives. The curved jib clears the patient and allows full 360 degree rotation once lifted, and the four point bariatric spreader bar widens the gap between shoulder and leg hooks so the sling distributes load rather than squeezing. This unit carries the integrated suspended weighing scale, so a weight is captured during the transfer instead of becoming a separate procedure that often does not happen at all in bariatric care. Supplied with a pre-owned battery. Sling and charger are sold separately.
What is included
| Item | Detail | Condition |
|---|---|---|
| Arjo Tenor hoist | Bariatric mobile floor lifter with curved jib and width-adjustable chassis legs | USED |
| Integrated weighing scale | Suspended scale fitted to the hoist | USED |
| Four point bariatric spreader bar | Wide-gap spreader bar for shoulder and leg hooks | USED |
| Battery | Sealed lead acid 24 V 4 Ah, part number NDA0100-20 | USED |
| Hand control | Handset for lift and lower | USED |
What is not included
| Item | Detail | Status |
|---|---|---|
| Slings | Selected by weight, body distribution, height and physical condition | SOLD SEPARATELY |
| Battery charger | Charging unit for the 24 V battery | ADD-ON |
| Spare battery | Second pack for rotation between charges | SOLD SEPARATELY |
| Scale verification | Calibration check of the weighing function against a certified reference | SOLD SEPARATELY |
| Thorough examination | Six monthly examination by a competent person under LOLER 1998 | SOLD SEPARATELY |
| Service and inspection | Engineer service and load testing | SOLD SEPARATELY |
Mandatory before any use with a patient
- This is lifting equipment used to lift persons. In Great Britain it requires a thorough examination by a competent person at least every six months under LOLER 1998, with a current report held before the equipment enters service.
- No sling is supplied. Slings must be matched to the individual by weight, body distribution, height and physical condition, and the safe working load printed on the sling label must be checked before every use.
- The lowest safe working load in the complete system governs. A 320 kg hoist used with a 250 kg sling is a 250 kg system, and the spreader bar rating applies in the same way.
- Slings must be inspected before every use and withdrawn from service if any fraying, damage or wear is found.
- The Tenor should be serviced and inspected only by suitably qualified personnel approved for this equipment.
Pre-owned battery, no charger supplied
The battery is pre-owned. Capacity in any sealed lead acid pack falls with age and cycle count, so the number of lifts available from a full charge cannot be stated for this unit and must be assessed once it is on charge. No charger is supplied, so a charger must be in place before the hoist can be brought into service. Where a bariatric caseload depends on the hoist being available at short notice, a fresh battery and a second pack on rotation are worth budgeting for. The battery is a sealed lead acid 24 V 4 Ah pack, part number NDA0100-20.
Weighing scale accuracy
The integrated scale is a measuring function on a pre-owned device and its accuracy has not been verified here. Before any weight from this hoist is used for a clinical decision, particularly weight-based drug dosing, the scale should be checked against a certified reference by a qualified engineer and then verified at the interval set by the operating organisation.
Checked before dispatch
- Cleaned and inspected.
- Powered up and function tested through the full hoisting range, with the hand control and mast panel confirmed.
- Emergency lowering override checked.
- Spreader bar, hooks, jib and mast checked for damage, distortion and secure fixing.
- Chassis leg adjustment, castors, brakes and battery discharge indicator checked.
These are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service, load test, scale verification and thorough examination are not included unless this listing states that the unit has been serviced. Ongoing inspection and six monthly thorough examination remain with the operating organisation once the equipment is in service.
Key features
Technical specifications
| Manufacturer | Arjo, formerly ArjoHuntleigh |
| Model | Tenor with weighing scale |
| Device type | Bariatric mobile patient hoist, floor lifter |
| Safe working load | 320 kg |
| Hoist weight, without battery, with scale | 66.4 kg |
| Hoisting range | 1225 mm |
| Minimum central suspension point height | 800 mm |
| Maximum height at maximum hoisting reach | 1405 mm |
| Maximum height, legs spread | 2025 mm |
| Minimum wall distance at maximum reach, legs spread | 335 mm |
| Minimum wall distance at minimum height, legs spread | 530 mm |
| Turning radius | 1650 mm |
| Spreader bar | Four point bariatric |
| Weighing scale | Suspended, integrated |
| Battery | Sealed lead acid, 24 V, 4 Ah, part number NDA0100-20 |
| Ingress protection | IPX4 |
| Electrical classification | Internally powered equipment, Type B applied part |
| Standards | EN and IEC 60601-1 |
| Condition | Pre-owned |
Delivery and access
- This is a large, heavy item at 66.4 kg with a turning radius of 1650 mm. Measure every access point on the route before ordering, including doorways, corridor turns and lift dimensions, and check the intended room can accommodate the turning circle.
- Dimensions given are approximate and should be treated as a guide for access planning rather than exact figures.
- Delivery is to ground floor only. Two people should be available to receive and move the item.
- Return shipping is at the buyer's expense and any delivery fee paid is non-refundable.
Routine care guidance
| Component | Action | Interval |
|---|---|---|
| Slings | Inspect webbing, stitching, loops and labels, withdraw any sling showing fraying or damage | Before each use |
| Spreader bar and hooks | Check hooks, latches and attachment points for wear and distortion | Before each use |
| Battery | Return to charge after use, check the discharge indicator, note any fall in the number of lifts | After each use |
| Brakes and castors | Confirm the brakes hold, clear hair and debris from the castor spindles | Weekly |
| Emergency lowering | Confirm the override operates | Weekly |
| Mast, jib and chassis | Inspect for cracks, corrosion, loose fasteners and leg adjustment function | Monthly |
| Weighing scale | Check against a known reference weight per local policy | Per local schedule |
| Thorough examination | Formal examination by a competent person under LOLER 1998 | At least every six months |
The above is general guidance. The manufacturer instructions for use and the operating organisation's moving and handling policy take precedence. Any hoist showing damage or a fault should be taken out of service until it has been inspected and repaired.