Fisher and Paykel MR810AEK Humidifier

Fisher & PaykelSKU FIS4119V
Price
ยฃ29999

Price shown excludes VAT.

VAT relief available on this product

Eligible customers can claim VAT relief on this product at checkout.

Quantity
Unit priceยฃ299.99
Totalยฃ299.99

Prefer a quote?
Key attributes
Brand
Fisher & Paykel
Category
Respiratory humidifier
SKU
FIS4119V
Options
2 to choose from

Fisher and Paykel MR810AEK Respiratory Humidifier, 230 V UK Model, Pre-owned

The Fisher and Paykel MR810 is a heated respiratory humidifier built to warm and humidify the gas delivered to a patient through a face, nasal or oral mask. It is the humidifier at the centre of the Fisher and Paykel 810 system, used alongside noninvasive ventilation and CPAP where dry gas at flow would otherwise dry the nose and mouth, thicken secretions and drive a patient off therapy within the first few nights. MR810AEK is the 230 V model built for the United Kingdom supply.

Humidification on the MR810 is set by the operator rather than measured at the airway. Three positions set the heater plate to roughly 45, 60 and 70 degrees Celsius, and with a heated breathing circuit fitted the gas reaching the patient sits in the region of 26 to 29, 30 to 33 and 33 to 36 degrees Celsius respectively. Fisher and Paykel quote the 810 system as delivering humidity at 31 degrees Celsius and 32 mg per litre for noninvasive ventilation. With an unheated circuit the delivered figures fall, because the gas loses heat along the tube and condenses on the way, which is the practical argument for running a heated circuit on anything other than a short run in a warm room.

Control is by microprocessor servo rather than a fixed heater. The unit senses flow from the power the heater plate draws and from thermistor feedback, and adapts, so output holds when flow changes instead of needing a manual correction. A heater wire indicator lights when the unit recognises a compatible heated circuit, so an operator can see at a glance whether the circuit is being driven. Faults are signalled on a single "See Manual" indicator which flashes a code pattern, and the codes are read from the Fisher and Paykel manual.

The unit takes the MR290 single use auto-fill chamber, the MR370 reusable chamber and the MR250, and drives Fisher and Paykel heater wire circuits in the RT202 and RT308 families, with the RT307 as an unheated option. The chamber, the circuit and the water are all items a clinical buyer holds already, so this listing is for the humidifier unit itself. It is classed as Type BF applied part equipment and the manual cites IEC 60601-1, IEC and EN 60601-1-2 and ISO 8185.

References

Reference MR810AEK
Brand Fisher and Paykel Healthcare
Model family MR810
Regional variant AEK, 230 V, United Kingdom
Device type Heated respiratory humidifier
Compatible chambers MR290, MR370, MR250
Compatible heated circuits RT202 and RT308 families
Compatible unheated circuit RT307
Condition Pre-owned

Features

  • Three humidity settings, with heater plate temperatures of roughly 45, 60 and 70 degrees Celsius.
  • Microprocessor servo control that senses flow from heater plate power draw and thermistor feedback, and adapts as flow changes.
  • Heater wire output for Fisher and Paykel heated circuits, with an indicator that lights when a compatible circuit is recognised.
  • Takes the MR290 auto-fill chamber for single patient use, or the MR370 reusable chamber where a decontamination route is in place.
  • Compact bench footprint at 1.7 kg empty, so it sits beside a ventilator rather than needing its own trolley.
  • Type BF applied part classification, with the manual citing IEC 60601-1, IEC and EN 60601-1-2 and ISO 8185.
  • Fault reporting through a single indicator that flashes a code pattern read from the manual.

Points to note before ordering

  • Unit only. No chamber, breathing circuit or water. The MR290, MR370 or MR250 chamber and an RT series circuit are to be sourced separately.
  • 230 V United Kingdom model. The AEK suffix is the 230 V build. The 115 V and 100 V versions carry different suffixes and are not interchangeable on supply.
  • Heated against unheated circuit. Delivered temperature and humidity at the patient are lower with an unheated circuit, and condensation in the tube is to be expected.
  • Pre-owned condition. Marks to the casing consistent with service use. To be electrically safety tested and function checked against the Fisher and Paykel instructions before clinical use.