The Vision Alpha is a mains powered intensive care ventilator carrying the Novalung name, documented in United Kingdom paediatric intensive care practice from 2009. It is a conventional positive pressure ventilator rather than an extracorporeal device, and it is offered here as a pre-owned unit with its configuration, modes and service history stated in writing by Elarix Medical before dispatch.
The Novalung name needs a word of explanation, because it carries two quite different meanings. Novalung GmbH became widely associated with extracorporeal lung assist, in particular the pumpless membrane device used to remove carbon dioxide without a conventional pump circuit, and Novalung marketed that product line under the phrase membrane ventilator. A buyer searching the Novalung name is often looking for that oxygenator rather than for a bedside ventilator. This unit is the latter: a ventilator that delivers breaths to the patient through an endotracheal tube and a breathing circuit. Novalung GmbH was merged fully into Xenios AG in 2019, and Xenios AG sits within Fresenius Medical Care, so technical support and spares for this model are arranged through independent biomedical engineering rather than through a current ventilator programme.
Specifications are the part this listing deliberately leaves open. No manufacturer data sheet, operating manual or service manual for the Vision Alpha is publicly available, and a ventilator is not a device on which figures should be inferred from a family resemblance to another model. Patient group, the modes fitted, pressure and volume ranges, trigger sensitivity, whether high frequency oscillation is present and the gas supply arrangement all vary by build and by software version. Elarix Medical reads those from the rating plate, the mode keys and the software version on the unit itself and states them in writing, rather than publishing a specification table that a buyer might plan a service around.
What a ventilator of this class needs in order to be put to work is more predictable, and is worth setting out plainly. It requires medical oxygen and medical air at pipeline pressure, a patient breathing circuit of the correct size for the patient group, active humidification, a flow sensor appropriate to the circuit, and a pre-use check against a test lung. Commissioning means verification of delivered volume, pressure and oxygen concentration against a calibrated gas flow analyser, a full alarm test, and an electrical safety test. None of that is included in this sale, and a ventilator is not returned to clinical service on the strength of a power-on test.
| Badge | Novalung |
| Model | Vision Alpha |
| Device type | Intensive care positive pressure ventilator |
| Device category | Life supporting equipment |
| Documented clinical use | United Kingdom paediatric intensive care, from 2009 |
| Corporate route | Novalung GmbH merged into Xenios AG in 2019; Xenios AG sits within Fresenius Medical Care |
| Patient group | Read from the unit and stated before dispatch |
| Modes fitted | Read from the unit and stated before dispatch |
| Serial number and software version | Stated in writing before dispatch |
| Condition | Pre-owned |
Points to note before ordering
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
This item is pre-owned and comes with a 90-day SelfiMed warranty, starting on the day it is delivered.
Read the full returns and warranty policy
This does not affect your statutory rights.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Written by people who bought from us.
Meical Equipment Advice and Guidance
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Read Article
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Read Article
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Read Article