Battery installation before
Defib Pads

Condition: Used
This item has been previously used and may show signs of cosmetic wear. However, it is in full operational condition and functions as intended. It could be a floor model or a store return. Please refer to the listing for comprehensive details and descriptions of any imperfections.

Important Note:

  • We do not have the facilities to calibrate our equipment.
  • We do not service medical items.

We strongly recommend that you have the item professionally serviced, calibrated, and cleaned before use.

The Philips Heartstart FR3 Defibrillator is specifically designed to be used efficiently during emergency situations. Its SMART Pads III have a convenient peel-and-place design that is suitable for both adults and children. With its compact size and lightweight construction, it can easily be moved around, even in tight or crowded spaces. The Quick Shock feature ensures rapid treatment by minimizing the time between shock delivery. In addition, the 3-Lead ECG cable provides critical information for accurate assessment and decision-making in non-cardiac arrest cases. Philips offers various data management solutions to assist in continuous improvement and excellence in patient care. The FR3 is built tough and versatile, meeting rigorous military standards through extensive testing. Its IP55 rating protects against dust and water jets, and it can withstand a 1,100-pound crush test. The FR3 allows for customisation to fit current and future protocols, making it highly adaptable.

The Hard case for FR3 is designed with room for a spare battery, spare AED pads and infant/child key. The Philips HeartStart FR3 status indicator can be seen through the clear window without having to remove the AED from the carrying case.

Expertly designed, the Philips HeartStart FR3 Defibrillator with Battery & Hard Case has a spacious interior for storing a spare battery, spare AED pads, and an infant/child key. Thanks to the clear window, you can easily monitor the device's status without even having to remove it from the protective carrying case - making it easy to access and transport in emergency situations.

What's included:

  • 1X FR3 Defibrillator
  • 1X Child Key
  • 1X Pads (expired)
  • 1X battery (please select year)
  • 1X Hard case

Specifications

Screen
  • Screen LCD color display, 320 x 240 pixels 2.8˝ x 2.1˝ (7.2 cm x 5.4 cm)
Bandwidth
  • Bandwidth 1 Hz to 30 Hz (-3dB), nominal (non-diagnostic)
Monitored Lead
  • Monitored lead Lead II using anterior-anterior adult pads placement
Environment/physical
Shock/drop
  • Meets MIL-STD-810F 516.5, Procedure IV (after a one-meter drop to any edge, corner, or surface in standby mode)
Sealing
  • Meets IEC529 class IP55 with battery installed
Temperature
  • Operating/standby: 32°–122°F (0°– 50°C)
Altitude
  • Meets IEC 60601-1:5.3 (1013 to 572 mbar (hPa), equivalent to air pressure from 0 to 15,000 feet; 0 to 4,572 meters) m
Vibration
  • Meets MIL-STD-810F 514.5 C-17
Patient analysis system
ECG analysis
  • Evaluates impedance of pads for contact, ECG rhythm and signal quality
Quick Shock
  • Typically arms in 8 seconds from the end of the “Stop CPR” prompt
Sensitivity/specificity
  • Meets AAMI DF80 requirements and AHA recommendations for adult defib
SMART CPR
  • Evaluates key characteristics of presenting VF and determines initial therapy.
FR3 primary battery
Type
  • Type 12 VDC, 4.7 Ah, lithium manganese dioxide Long-life primary cells
Capacity
  • Please consult User’s Manual for capacity specifications.
Standby life
  • 3 years minimum when stored under standby environmental conditions
Shelf life
  • 5 years
SMART Pads III
Application
  • Peel and place pads can be removed from packaging and stored in carry case.
Infant/Child Key
Function
  • Selects therapy for infants or children under 55 lbs (25 kg) or 8 years old
FR3 data card
Function
  • Function Stores a minimum of 8 hours of ECG, event, and voice recording.
Automated and user-activated self-tests
Function
  • Places FR3 into a scenario-based training mode and simulates shock therapy
Type
  • 10.8 Volt, 4.5 Ah Li-ion battery
Defibrillator
Models
  • Models 861388 text display 861389 ECG and text display
Waveform
  • SMART Biphasic Truncated Exponential waveform parameters adjust as a function of patient impedance.
Shock delivery
  • Via defibrillator pads placed in the anterior-anterior position for adults, infants and children.
Indicators
  • High-res LCD, beeper, voice prompts, tones, speaker, connector socket
Advanced mode
  • Advanced mode Configurable using optional HeartStart Configure software
Environmental/Physical Requirements
Sealing
  • Meets IEC529 class IP55 with battery installed
Operating Temperature
  • Operating/standby: 32°–122°F (0°– 50°C)
Operating Altitude
  • Meets IEC 60601-1:5.3 (1013 to 572 mbar (hPa), equivalent to air pressure from 0 to 15,000 feet; 0 to 4,572 meters)
Shock/Drop Abuse Tolerance
  • Meets MIL-STD-810F 516.5, Procedure IV (after a one-meter drop to any edge, corner, or surface in standby mode)
Vibration
  • Meets MIL-STD-810F 514.5 C-17
Physical
Size
  • 2.7˝ high x 5.3˝ wide x 8.7˝ deep (6.9 cm x 13.5 cm x 22.1 cm)
Weight
  • 3 lbs 8 oz (1.6 kg) with FR3 primary battery installed

Please read our terms and conditions carefully before using any medical device purchased from SelfiMed.

Potential Risks

New, used, replaced, or repaired medical devices can be dangerous. They may cause serious injury or death to the user or patient.

SelfiMed is not authorized to give medical advice or operate medical devices. We do not provide service or repairs for medical devices. Do not buy used medical equipment if you have a health emergency or a seriously ill relative unless advised by an expert.

Required Checks and Maintenance

All medical devices sold by SelfiMed come from NHS hospitals but with an unknown service history. Therefore, they may require maintenance and thorough health and safety checks before use.

These checks must be carried out by a qualified professional to ensure patient and user safety.

Liability Disclaimer

SelfiMed assumes no liability for the misuse or improper use of medical devices, including incidents that result in severe injury or death.

Regulatory Compliance

Our products are NHS-approved and therefore comply with the essential requirements of the UK Medical Devices Regulations and the EU Council Directive 93/42/EEC, as amended by Directive 2007/47/EC, and are classified as Class IIa devices.

The sale of this item may be subject to regulation by UK, EU, and FDA regulatory agencies. You must be an authorized purchaser to bid on this item.

Consult a Qualified Professional

The members of the SelfiMed UK store are not qualified to give medical advice on any medical equipment. For any questions related to the use of medical devices, please consult your General Practitioner (GP), physician, nurse, or medical technologist.

For further inquiries, contact SelfiMed at info@selfimed.com or +44 780 2644 820.

Additional information

Global Shipping: We offer worldwide shipping for our medical equipment with top-notch services. All our products come with tracking options provided by reputable national and international shipping companies.

Personal Collection: Alternatively, you can opt to collect your purchased item directly from our Leeds, LS12 4HP shop. To arrange a collection time, please call us at 07802644820 or email us at info@selfimed.com.

Import Duties and Taxes: Please note that import duties and taxes are not included in the item price or shipping quote. The responsibility for these charges lies with the buyer. Kindly check with your country's customs office for information on additional fees before placing a bid or making a purchase.

Customs fees are typically charged by the shipping company or collected upon item pickup. If the buyer fails to assist Customs and the shipping company in clearing and paying import duties and taxes, SelfiMed will not entertain refund requests.

Contact Us: For any inquiries regarding shipping or import/customs duties, feel free to reach out to us. We are here to assist you and provide the necessary information.

Used & Like New items

  • All used items (or Like New) are shipped with a minimum guarantee of 30 days.
  • If the item is defective or does not match the description, you can return it within 30 days for a replacement item or a refund.
  • If you are unsatisfied with your purchase, you can return it within 30 days for a full refund.

New medical equipment

  • You can return new medical equipment within 30 days for a full refund, with or without justification.
  • You will receive a full refund if the item is unopened and contains the original packaging.

It's important to note that SelfiMed does not refund shipping costs outside the UK under any circumstances.

 **When are you eligible for a full refund, including shipping charges?**

You will receive a complete reimbursement, covering your shipping expenses, in the following scenarios:

1. If you cancel your order before the item is dispatched.

2. If the item is not as described.

3. If the item sustains damage during the delivery process.

4. If the courier loses the item, preventing it from reaching you.

 **Under what circumstances might you receive only a partial refund?**

1. If the item has already been dispatched and you change your mind without any damage, you will receive a refund for the item's price minus the shipping fees. Additionally, you will be responsible for the return shipping costs in this case.

2. For brand-new items that have been opened and used, even briefly, without defects, we may accept the return but deduct 40% from the original item price. It's important to note that shipping fees will not be refunded in this situation, and you will be responsible for covering the return shipping costs.

Please be aware that we do not furnish CE certificates for medical devices sent outside the UK. Before placing an order, we highly advise verifying your local customs regulations.

If your shipment is returned at the border, we must convey that we will not reimburse the shipping cost. Nonetheless, if the item is returned, we will refund the purchase price. We appreciate your understanding on this matter.

The medical items come directly from NHS hospitals and are sold in good working conditions unless otherwise stated. Therefore, it is your responsibility as the purchaser to have them tested, calibrated or serviced by a professional before any clinical use on humans.

NOTE:

Regardless of the origin of the Equipment, the documentation provided or the identification appearing on the Equipment, the Equipment described and offered here is in no way certified, recommended or provided for a specific use. Buyer agrees that Seller shall not be liable for any injury or damage, incidental or consequential, in any way associated with the Equipment. By bidding on this Equipment, the buyer indicates its acknowledgement and agreement to the terms of this disclaimer.