Philips Heartstart XL+ Defibrillator with Brand New Battery
£749.99
This item
Philips M3713A Adult AED Pads
£59.99
The Philips HeartStart XL+ is a defibrillator and monitor built to carry a resuscitation from first responder through to advanced life support on one device. It offers four clinical modes: Monitor, Manual Defibrillation, AED and Pacer. A basic life support responder can work in AED mode under voice and text prompts, and the same unit switches to manual defibrillation and pacing when the ALS team arrives, which removes the handover to a second machine at the worst possible moment. Defibrillation uses Philips SMART Biphasic, a low energy biphasic truncated exponential waveform with impedance compensation. Supplied here with a brand new battery.
Mandatory before any use on a person
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service, output energy verification and certification are not included unless this listing states that the unit has been serviced. Ongoing planned maintenance and periodic electrical safety testing remain with the operating organisation.
Fitted options
Pacing, SpO2, EtCO2 and non-invasive blood pressure were optional on the HeartStart XL+ and were not fitted to every unit. Where a particular capability is essential, ask before ordering and the configuration will be confirmed from the device information screen. The unit is offered on the basis of the specification and photographs shown.
| Component | Action | Interval |
|---|---|---|
| Ready For Use indicator | Check the indicator and investigate any change in status | Daily |
| Pads | Confirm sealed pads are in date and a spare set is held | Weekly |
| Operational test | Run the shock delivery test with the test load per local policy | Per local schedule |
| Battery | Keep on AC between uses, note any fall in run time | After each use |
| Cables and connectors | Inspect the ECG cable, mains lead and pads connector for damage | Weekly |
| Printer | Check paper stock and print quality where the recorder is used | Weekly |
| Housing and display | Wipe down per local policy, inspect for cracks and fluid ingress | Weekly |
| Service and output verification | Engineer service and delivered energy check | Per local schedule |
The above is general guidance. The manufacturer instructions for use and the operating organisation's resuscitation and medical device policies take precedence. Any unit that fails a self test or an operational check should be taken out of service immediately and replaced on the trolley by a working device.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article