Couldn't load pickup availability
Got questions?
Feel free to get in touch
Condition: Used
This item has been previously used and may show signs of cosmetic wear. However, it is in full operational condition and functions as intended. It could be a floor model or a store return. Please refer to the listing for comprehensive details and descriptions of any imperfections.
Important Note:
- We do not have the facilities to calibrate our equipment.
- We do not service medical items.
We strongly recommend that you have the item professionally serviced, calibrated, and cleaned before use.
The ResMed Stellar 150 CPAP Unit is designed to offer ventilation for adult and pediatric patients (30 lb/13 kg and above) who are not dependent on external support and can breathe on their own. It is intended for those who suffer from respiratory insufficiency, respiratory failure, and may or may not have obstructive sleep apnea. This device can be used noninvasively or invasively with an uncuffed or deflated tracheostomy. It can be used stationary in a hospital or at home, as well as on the move, such as when using a wheelchair.
Product Specifications
- Height - 120 mm
- Weight - 2.1 kg
- Breadth - 170 mm
- Length - 230 mm
- Sound pressure level - 31 dBA with uncertainty of 3 dBA as measured according to ISO 17510 – 1:2007.
- Maximum single fault steady pressure - 60 cm H2O (in all modes)
- Breathing resistance under single fault - 2 cm H2O at 30 L/min; 7.2 cm H2O at 60 L/min
- Electromagnetic compatibility - Product complies with all applicable electromagnetic compatibility requirements (EMC) according to IEC60601-1-2, for residential, commercial, and light industry environments.
- Aircraft use - Medical-Portable Electronic Devices (M-PED) that meet the Federal Aviation Administration (FAA) requirements of RTCA/DO-160 can be used during all phases of air travel without further testing or approval by the airline operator. ResMed confirms that the Stellar meets RTCA/DO-160 requirements
- Storage and transport humidity - 10%–95% non-condensing
- Tubing - Flexible plastic, 6’ 6” (2 m) or 9’ 10” (3 m) length (0.9”/22 mm diameter) SlimLine air tubing Flexible plastic, 6’ (1.83 m) length (0.6”/15 mm diameter
- Air outlet - 0.9” (22 mm) taper, compatible with ISO 5356-1:2004 Anaesthetic & Respiratory Equipment - Conical Connectors
- External DC Power Supply - 24 V, 3 A
- Screen Resolution - Dimension (L x W x H): 3” x 2.5” x 0.1” (76.9 mm x 63.9 mm x 3.15 mm) Resolution: 320 x 240 pixels
- Operating pressure range - •IPAP: 3 cm H2O to 40 cm H2O (in S, ST, T, PAC mode) •PS: 0 cm H2O to 37 cm H2O (in S, ST, T, PAC mode) •EPAP: 3 cm H2O to 25 cm H2O (in S, ST, T, iVAPS, PAC mode) •CPAP: 4 cm H2O to 20 cm H2O (in CPAP mode only) •Min PS: 0 cm H2O to 20 cm H2O (in iVAPS mode) •Max PS: 0 cm H2O to 30 cm H2O; 8 cm H2O to 30 cm H2O when AutoEPAP is on (in iVAPS mode) •Min EPAP/Max EPAP: 3 cm H2O to 25 cm H2O (in iVAPS mode when AutoEPAP is set to on) Note: iVAPS mode is only available in Stellar 150.
- IEC 60601-1 - Class II (Clause 3.14—double insulation). This adherence means the need for an protective earthing (ie, an earthed plug) is not necessary. •Type BF •Continuous operation
- Operating humidity - 10%–95% non-condensing
- Pressure measurement - Internally mounted flow transducer
- Standard air filter - Electro static fibre mesh with TPE frame structure. Bacterial filtration efficiency of 99.540% on area weight 100g/m².
- Flow measurement - Internally mounted pressure transducer
- Modes - CPAP, S, T, ST with optional iBR, PAC, iVAPS with iBR and optional Auto EPAP
- Internal Battery - Lithium-Ion battery, 14.4 V, 1.6 Ah, 23 Wh Operating hours: 2 h with a new battery under normal conditions (see below). Patient type: home chronic; pressure: IPAP/EPAP 15/5 cm H2O; mask type: Ultra Mirage; air tubing: 6’ 6” (2 m); leak: 0; respiratory rate: 20 bpm; battery capacity: 100% Patient type: hospital acute; pressure: IPAP/EPAP 20/5 cm H2O; mask type: Ultra Mirage; air tubing: 6’ 6” (2 m); leak: 0; respiratory rate: 45 bpm; battery capacity: 100%
- Power supply unit - AC 100–240V, 50–60Hz, 2.2 A, max. 65 W
- Storage and transport temperature - -4°F (-20°C) to +140°F (60°C); +122°F (+50°C*)
- Housing construction - Flame retardant engineering thermoplastic
- Operating temperature - +32°F (0°C) to + 95°F (35°C)
- Max FLow - > 200 L/min at 20 cm H2O null
- Therapy pressure tolerance - IPAP: ± 0.5 cm H2O ± 10% of set pressure (end of inspiration) EPAP/PEEP: ± 0.5 cm H2O ± 4% of set pressure CPAP: ± 0.5 cm H2O ± 10% of set pressure null
- Flow Accuracy - ± 5 L/min or 20% measured value, whichever is greater null
Water chamber- not included
CPAP MASK- Order here
CPAP Hose - Order here
"For customers buying CPAP masks from Selfimed UK:
Please note that CPAP masks & CPAP accessories (water chamber, hose, filters etc) are considered medical equipment and, as such, cannot be returned once opened or used. This policy is in place to ensure the health and safety of all our customers.
However, we do accept returns of non-opened masks if they are still inside their original packaging, within 30 days from the date of delivery. Please be aware that the customer will be responsible for the return cost. We will only issue a refund once we have received the returned item and ensured that it has never been used before.
Due to the nature of CPAP masks, once the packaging has been opened or the mask has been used, Selfimed cannot accept returns or exchanges. This is because CPAP masks come into direct contact with the face and respiratory system, and we must maintain strict hygiene standards to prevent any potential health risks.
Selfimed advises all customers to carefully consider their purchase before opening the packaging or using the CPAP mask. If you have any questions or concerns about your CPAP mask purchase, please feel free to contact our customer service team for assistance.
Thank you for your understanding and cooperation."
Please read our terms and conditions carefully before using any medical device purchased from SelfiMed.
Potential Risks
New, used, replaced, or repaired medical devices can be dangerous. They may cause serious injury or death to the user or patient.
SelfiMed is not authorized to give medical advice or operate medical devices. We do not provide service or repairs for medical devices. Do not buy used medical equipment if you have a health emergency or a seriously ill relative unless advised by an expert.
Required Checks and Maintenance
All medical devices sold by SelfiMed come from NHS hospitals but with an unknown service history. Therefore, they may require maintenance and thorough health and safety checks before use.
These checks must be carried out by a qualified professional to ensure patient and user safety.
Liability Disclaimer
SelfiMed assumes no liability for the misuse or improper use of medical devices, including incidents that result in severe injury or death.
Regulatory Compliance
Our products are NHS-approved and therefore comply with the essential requirements of the UK Medical Devices Regulations and the EU Council Directive 93/42/EEC, as amended by Directive 2007/47/EC, and are classified as Class IIa devices.
The sale of this item may be subject to regulation by UK, EU, and FDA regulatory agencies. You must be an authorized purchaser to bid on this item.
Consult a Qualified Professional
The members of the SelfiMed UK store are not qualified to give medical advice on any medical equipment. For any questions related to the use of medical devices, please consult your General Practitioner (GP), physician, nurse, or medical technologist.
For further inquiries, contact SelfiMed at info@selfimed.com or +44 780 2644 820.
Additional information
Global Shipping: We offer worldwide shipping for our medical equipment with top-notch services. All our products come with tracking options provided by reputable national and international shipping companies.
Personal Collection: Alternatively, you can opt to collect your purchased item directly from our Leeds, LS12 4HP shop. To arrange a collection time, please call us at 07802644820 or email us at info@selfimed.com.
Import Duties and Taxes: Please note that import duties and taxes are not included in the item price or shipping quote. The responsibility for these charges lies with the buyer. Kindly check with your country's customs office for information on additional fees before placing a bid or making a purchase.
Customs fees are typically charged by the shipping company or collected upon item pickup. If the buyer fails to assist Customs and the shipping company in clearing and paying import duties and taxes, SelfiMed will not entertain refund requests.
Contact Us: For any inquiries regarding shipping or import/customs duties, feel free to reach out to us. We are here to assist you and provide the necessary information.
Used & Like New items
- All used items (or Like New) are shipped with a minimum guarantee of 30 days.
- If the item is defective or does not match the description, you can return it within 30 days for a replacement item or a refund.
- If you are unsatisfied with your purchase, you can return it within 30 days for a full refund.
New medical equipment
- You can return new medical equipment within 30 days for a full refund, with or without justification.
- You will receive a full refund if the item is unopened and contains the original packaging.
It's important to note that SelfiMed does not refund shipping costs outside the UK under any circumstances.
**When are you eligible for a full refund, including shipping charges?**
You will receive a complete reimbursement, covering your shipping expenses, in the following scenarios:
1. If you cancel your order before the item is dispatched.
2. If the item is not as described.
3. If the item sustains damage during the delivery process.
4. If the courier loses the item, preventing it from reaching you.
**Under what circumstances might you receive only a partial refund?**
1. If the item has already been dispatched and you change your mind without any damage, you will receive a refund for the item's price minus the shipping fees. Additionally, you will be responsible for the return shipping costs in this case.
2. For brand-new items that have been opened and used, even briefly, without defects, we may accept the return but deduct 40% from the original item price. It's important to note that shipping fees will not be refunded in this situation, and you will be responsible for covering the return shipping costs.
Please be aware that we do not furnish CE certificates for medical devices sent outside the UK. Before placing an order, we highly advise verifying your local customs regulations.
If your shipment is returned at the border, we must convey that we will not reimburse the shipping cost. Nonetheless, if the item is returned, we will refund the purchase price. We appreciate your understanding on this matter.
The medical items come directly from NHS hospitals and are sold in good working conditions unless otherwise stated. Therefore, it is your responsibility as the purchaser to have them tested, calibrated or serviced by a professional before any clinical use on humans.
NOTE:
Regardless of the origin of the Equipment, the documentation provided or the identification appearing on the Equipment, the Equipment described and offered here is in no way certified, recommended or provided for a specific use. Buyer agrees that Seller shall not be liable for any injury or damage, incidental or consequential, in any way associated with the Equipment. By bidding on this Equipment, the buyer indicates its acknowledgement and agreement to the terms of this disclaimer.