ResMed AirCurve 11 VAuto Bi-Level Bipap With HumidAir- Complete Bundle
£1,569.99
This item
Resmed AirFit F40 Full Face CPAP Mask
£99.99
The ResMed AirCurve 11 VAuto is a bi-level positive airway pressure device that delivers a higher pressure on inspiration and a lower pressure on expiration, so the wearer breathes out against less pressure than the level holding the airway open. The VAuto algorithm adjusts those pressures through the night inside the range set by the prescribing clinician rather than holding a single fixed value.
The device is supplied with the HumidAir humidifier fitted, a colour touchscreen for navigation, SlimLine air tubing, a standard filter, water chamber, mains power supply, SD card and a carry case.
| Item | Detail | Condition |
|---|---|---|
| AirCurve 11 VAuto device | Bi-level unit with the HumidAir humidifier fitted | NEW |
| SlimLine air tubing | Unheated ResMed SlimLine tubing | NEW |
| Standard filter | Disposable air inlet filter, one fitted | NEW |
| Water chamber | Standard tub for the HumidAir humidifier | NEW |
| Power supply unit | Mains power supply and lead | NEW |
| Carry case | Case sized for the device and supplied accessories | NEW |
| SD card | Fitted for on-device therapy data recording | NEW |
| User manual | Manufacturer user guide | NEW |
| Item | Detail | Status |
|---|---|---|
| Mask and headgear | Chosen to fit the wearer and the prescribed pressures | SOLD SEPARATELY |
| Heated air tubing | ClimateLineAir 11 tubing, used with Climate Control | SOLD SEPARATELY |
| Spare filters | Consumable, renewed on the routine care schedule | SOLD SEPARATELY |
| Side cover | Blank cover for running the device without humidification. The HumidAir humidifier is fitted in its place | NOT INCLUDED |
| DC converter | Needed for 12 V operation away from mains power | NOT INCLUDED |
| Distilled water | Used to fill the humidifier chamber | NOT INCLUDED |

New and boxed
Therapy pressures are set by the prescribing clinical service
Fixed pressure CPAP holds one pressure across the whole breathing cycle, which means the wearer exhales against the same pressure that is holding the airway open. Where the prescribed pressure is high, or where breathing out already takes effort, that resistance is a common reason therapy is abandoned in the first weeks. A bi-level device separates the two levels: a higher inspiratory pressure supports the breath in, and a lower expiratory pressure lets the breath out. The gap between them, the pressure support, is what changes both the comfort of the breath and the volume moved on each cycle.
The VAuto part of the name describes how those levels behave overnight. Instead of sitting at two fixed values, the device raises and lowers the expiratory pressure in response to airway resistance and carries the inspiratory pressure with it, so the pressure support stays constant while the underlying pressure tracks what the airway needs at that moment. Sleeping position, sleep stage and nasal congestion all move that requirement through the night, and a single fixed setting has to be high enough to cover the worst part of it.
Two limitations are worth knowing before purchase. The tubing supplied is unheated, so in a cold bedroom with humidification set high, condensation can collect in the tube; heated tubing and Climate Control address this and are bought separately. The device also runs from mains power with no internal battery, so it travels in its case but does not run unplugged. It is the wrong choice in two situations: where the prescription is straightforward fixed or auto-adjusting CPAP, in which case a bi-level adds cost and set-up complexity for no clinical gain, and where a person depends on ventilation to sustain breathing, since this device assists spontaneous breathing rather than replacing it.

| Manufacturer | ResMed |
| Model | AirCurve 11 VAuto |
| Device type | Bi-level positive airway pressure, auto-adjusting |
| Therapy delivery | Independent inspiratory and expiratory pressure |
| Humidification | Integrated HumidAir humidifier with Climate Control |
| Air tubing supplied | SlimLine, unheated |
| Interface | Colour touchscreen with start and stop button |
| Comfort settings | Adjustable ramp |
| Data recording | SD card supplied, myAir app in supported regions |
| Weight | 1.1 kg |
| Power supply | 100 to 240 V AC |
| Certification | CE marked, EU MDR compliant |
Specification limited to what is confirmed
| Component | Interval |
|---|---|
| Air tubing | Renew every 1 to 3 months |
| Air inlet filter | Renew every 1 to 3 months, or sooner where deposits are visible |
| Water chamber | Renew every 6 to 12 months |
| Mask cushion | Renew as required, following the mask instructions for use |
Intervals follow manufacturer guidance and are shortened where the device is used in a shared or institutional setting.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article