24/7 Chat Available
24/7 Chat Available
Brand new
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Compatible IPAD SP1 Defibrillator Battery - Next Day Delivery
£249.99
This item
The iPAD SP1 Defibrillator Battery is designed exclusively for use with all models of the iPAD SP1 AED. Reliable and easy to replace, this official battery ensures your defibrillator is always rescue-ready when every second counts.
With a shelf life of up to 4 years and the capacity to deliver a minimum of 200 shocks, this battery provides the dependable power needed to support life-saving interventions in emergencies.
Long Battery Life – Up to 4 years from the date of manufacture.
High Capacity – Provides at least 200 shocks.
Compatibility – Designed exclusively for the iPAD SP1 Defibrillator.
Non-Rechargeable – Simple replacement with no recharging required.
Trusted Manufacturer – Produced by iPAD for guaranteed reliability.
Product: iPAD SP1 Defibrillator Battery
Battery Type: Disposable / Non-rechargeable
Shelf Life: Up to 4 years
Shock Capacity: Minimum 200 shocks
Compatibility: iPAD SP1 AED only
Manufacturer: iPAD
Emergencies are unpredictable, and a defibrillator is only effective if it has reliable power. Keeping an additional SP1 battery on hand ensures your AED is always operational — whether one is depleted during a rescue or reaches the end of its shelf life.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article