SKU SCH4060W

Schuco 120 Electrosurgery Unit

Original price £0.00 - Original price £0.00
Original price £0.00
£399.99
£399.99 - £399.99
Current price £399.99
Availability:
Only 1 left!
PARCEL CONTROL
Next Day Hurry

UK mainland · dispatch before 1pm Mon–Fri
Delivery Mon–Sat

Schuco 120 Electrosurgery Unit, Machine Only, Pre-Owned

The Schuco 120 is a radiofrequency electrosurgical generator for minor and medium surgery, offering pure cut, blend, forced coagulation, soft coagulation and, with an adapter, bipolar coagulation. It is the unit widely used in minor operations rooms, dermatology and podiatry clinics, where one generator has to cover cutting, haemostasis and lesion work.

This listing is for the generator only. The complete pack is normally supplied with a reusable handle with finger switches, a footswitch, a 2 m power lead, a steel neutral electrode of 120 x 160 mm, a cable for a disposable neutral plate, an assorted pack of 10 electrodes of 5 cm and the user manual. None of that is supplied here, and the unit is pre-owned. It suits a buyer who already holds compatible accessories, or who is buying a second generator to sit alongside an existing set.

What is included

Item Detail Condition
Schuco 120 generator Benchtop electrosurgical unit, machine only, with no accessories of any kind USED

What is not included

Item Detail Status
Mains power lead 2 m lead in the complete pack. Required to power the unit at all ADD-ON
Monopolar handpiece Reusable handle with finger switches in the complete pack ADD-ON
Neutral electrode Steel plate of 120 x 160 mm in the complete pack. The unit does not deliver monopolar output without a plate ADD-ON
Neutral plate cable Cable for a disposable neutral plate, reference 5365 ADD-ON
Active electrodes Assorted electrodes of 5 cm, pack of 10 in the complete pack ADD-ON
Footswitch In the complete pack. Optional where a finger-switched handle is used NOT INCLUDED
Bipolar adapter and forceps Needed for bipolar work, which is not available on the unit alone NOT INCLUDED
User manual Available from the manufacturer NOT INCLUDED
Smoke evacuation Separate extraction unit and filters NOT INCLUDED

Checked before dispatch

  • Powered on, with the display, self-check routine and mode selection observed.
  • Power adjustment and the digital output reading checked through the front panel.
  • Case, sockets, switches and mains inlet inspected for damage.
  • Unit cleaned inside and out of the accessible areas.
  • Output into a test load was not verified, since no handpiece, electrode or patient plate accompanies this unit.

These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included, and this item may require service and calibration. Planned maintenance, periodic electrical safety testing and ongoing maintenance under PUWER 1998 remain with the operating organisation.

Not usable on a patient as supplied

  • Monopolar output requires a compatible handpiece, active electrode and patient plate with its cable. None are supplied here, and the unit is not fit for clinical use until they are fitted.
  • Before any clinical use, output accuracy and the plate circuit monitoring are verified by a qualified engineer against a test load, and the unit passes electrical safety testing.
  • Plate contact monitoring depends on the correct type of neutral electrode being fitted. A plate that does not match the monitoring the generator expects removes a safety function the operator may assume is working.
  • Electrosurgery is carried out only by clinicians trained in its use, under local policy covering implanted electronic devices, alcohol based skin preparation, oxygen enriched atmospheres and surgical smoke.

What the generator does and why machine only matters

An electrosurgical generator turns mains power into a high frequency current that cuts and coagulates tissue through the electrode rather than by heat conducted from a hot tip. That distinction is the point of the technology. A pure cut waveform parts tissue with very little lateral thermal spread, so a specimen taken for histopathology arrives at the laboratory readable rather than charred. Adding coagulation into the same waveform gives a blend that cuts through a dry field, which is what makes larger excisions practical in a treatment room. Forced coagulation sears superficially for surface lesions, and soft coagulation drives deeper without carbonising, which is what seals a bleeding vessel.

In monopolar mode the current has to leave the patient somewhere, and that somewhere is the patient plate. The plate is not an accessory in the ordinary sense: it is half the circuit, and a plate that is poorly sited, partly lifted or of the wrong type concentrates the return current into a small area of skin. That is the mechanism behind return electrode burns, and it is why this generator monitors the plate circuit continuously and why the split plate design exists. A buyer taking a machine-only unit is therefore taking one half of a system, and the half being supplied is the half that cannot cause harm on its own.

The trade-off is straightforward and worth stating plainly. Machine only is the right purchase for a clinic that already runs Schuco 120 units and holds handpieces, plates and leads in stock, or for a service holding a spare generator against a breakdown. It is the wrong purchase for anyone setting up minor surgery from scratch, because the accessories then have to be sourced separately and will usually cost more assembled piecemeal than a complete pack. It is also the wrong purchase where bipolar work is the main requirement, since bipolar on this unit depends on an adapter and forceps that are not supplied, and it is not a substitute for a dedicated bipolar generator in a theatre setting.

Key features

Five operating modes, covering pure cut, blend, forced coagulation, soft coagulation and bipolar with an adapter, so one generator handles excision, surface lesion work and haemostasis without changing machines.
Pure cut with minimal thermal spread, dissecting without downward pressure or drag on the blade, which leaves excised tissue readable for histopathology rather than degraded at the margins.
Blend mode, combining cutting and coagulation in a single waveform so the operator works in a haemostatic field and the view of the site is not lost to bleeding.
Soft coagulation without carbonisation, raising tissue resistance so the effect penetrates rather than charring the surface, which is what seals a vessel instead of laying a crust over it.
Continuous patient plate monitoring, with contact checked through a split neutral electrode, so a plate lifting during a procedure is detected rather than discovered afterwards.
Digital reading of delivered power, showing what is actually reaching the tissue rather than a dial position, which makes settings repeatable between sessions and between operators.
Handle control of output, allowing mode and power to be driven from the handpiece so attention stays on the surgical field, with footswitch control available as an alternative.
Self-check on start-up, with microcontroller monitoring of the operating function, so a fault in the output stage is signalled before a procedure begins.
Selectable mains input, accepting 115 or 230 V AC at 50 to 60 Hz, which allows the unit to be used across sites without a converter.

Technical specifications

Brand Schuco
Model 120 electrosurgery unit
Reference LD-S-10100-20
Manufacturer LED SpA, Italy, supplied in the United Kingdom as the Schuco 120
Product type Radiofrequency electrosurgical generator, monopolar with bipolar by adapter
Condition Pre-owned, machine only
Modes Cut, blend, forced coagulation, soft coagulation, bipolar with adapter
Maximum output, cut 120 W into 250 ohms
Maximum output, blend 90 W into 200 ohms
Maximum output, forced coagulation 80 W into 150 ohms
Maximum output, soft coagulation 60 W into 100 ohms
Maximum output, bipolar 40 W into 100 ohms
Working frequency 600 kHz
Patient circuit Type F
Monitoring Patient and plate circuit, output power, self-check
Input voltage 115 or 230 V AC, selectable
Mains frequency 50 to 60 Hz
Electrical input power 300 VA
Dimensions (W x H x D) 254 x 104 x 288 mm
Weight 5 kg
Standards EN 60601-1, EN 60601-1-2, EN 60601-2-2

Specification limited to what is confirmed

  • Performance figures above are manufacturer data for the Surtron 120 generator sold in the United Kingdom as the Schuco 120. They describe the model, not measured output from this individual unit, which has not been verified against a test load.
  • Serial number, production year, the position of the voltage selector as shipped, accessory socket types and any service history are not confirmed and can be checked against the rating label and the rear panel on request.
  • Hours of previous use are unknown, as is usual for pre-owned equipment of this type.

Condition and history

Pre-owned, previously in clinical service, with cosmetic marks consistent with use. Photographs form part of the description and show the actual unit offered.
Supplied as the generator alone, so a working system has to be assembled around it. The accessories listed above are sourced before the unit can be commissioned.
Ongoing maintenance sits under PUWER 1998, alongside periodic electrical safety testing and output verification, and remains with the organisation operating the equipment.

Checks in service

Check Interval
Inspect handpiece, electrode and plate leads for damaged insulation before connection Before every procedure
Confirm plate siting, full contact and the monitoring indication Before every procedure
Observe the self-check and the digital power reading at power-up Before every session
Clean the case, panel and accessible sockets After every session
Fit fresh single use electrodes, or reprocess reusable ones to the manufacturer instructions Every patient
Electrical safety testing and verification of output against a test load Annually, and after any repair or transport

Intervals follow common practice for electrosurgical equipment and are adjusted to the manufacturer instructions and local medical device policy.