24/7 Chat Available
24/7 Chat Available
Before You Order This Bed
Please read and confirm before adding to cart
Measure your access points first
Please check the bed dimensions shown on the product page and measure your front door, hallways, stairways and room doorway before ordering. The dimensions provided are approximate and may vary slightly between models. We strongly recommend allowing extra clearance beyond the stated measurements to ensure the bed can be delivered and moved into the room safely.
Ground floor delivery only
Beds are delivered fully assembled to the ground floor only. Upper floor or room placement is not included.
Returns cost the original delivery fee
If the bed cannot fit into your home, return shipping is at your expense and the original delivery fee is non-refundable.
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Add the whole set in one go.
Hill Rom Siderails Electric Hospital Bed with Hospital Mattress
£799.99
This item
This is a fully profiling electric acute care bed from the Hill-Rom 900 platform, supplied with full-length tubular siderails and a compatible hospital mattress. Electric height, backrest, thigh, foot section and Trendelenburg adjustment let clinical staff position patients for nursing procedures, transfers and pressure area management without manual handling. Safe working load is 250 kg and the deck drops to 38.9 cm, a low height that supports safe patient egress and falls reduction. Central braking and steer control makes ward transport manageable for one person. The unit is pre-owned NHS stock in working order.
| Item | Detail | Condition |
|---|---|---|
| Electric hospital bed | Hill-Rom 900 platform profiling bed with 90 x 200 cm sleep deck | USED |
| Siderails | Full-length tubular siderails, both sides, with integrated controls | USED |
| Hospital mattress | Compatible mattress sized for the 90 x 200 cm deck | USED |
| Mains lead | Power lead for the bed's electrical system | USED |
| Item | Detail | Status |
|---|---|---|
| 3-mode bed exit alarm | Factory option, not supplied as standard on this unit | SOLD SEPARATELY |
| Fifth castor | Central castor option for improved manoeuvrability | SOLD SEPARATELY |
| Pressure redistributing mattress | Dynamic or high specification foam surface where clinically indicated | SOLD SEPARATELY |
| IV pole and drainage bag hooks | Accessory mounted equipment | SOLD SEPARATELY |
| Patient handset | Pendant control where not integrated in the siderails | SOLD SEPARATELY |
| Nurse call interface lead | Connection to a ward nurse call system | SOLD SEPARATELY |
| Service and commissioning | Engineer inspection, electrical safety test and function test | SOLD SEPARATELY |
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included unless this listing states that the unit has been serviced. Planned maintenance and periodic electrical safety testing remain with the operating organisation once the bed is in service.
| Manufacturer | Hill-Rom, a Baxter company |
| Platform | Hill-Rom 900 |
| Product type | Electric profiling hospital bed |
| Safe working load | 250 kg, patient plus mattress plus accessories |
| Bed weight | 144 kg |
| Height adjustment | 38.9 to 76.8 cm |
| Sleep deck size | 90 x 200 cm |
| Backrest angle | 0 to 65 degrees |
| Thigh section angle | 0 to 28 degrees |
| Foot section angle | Minus 22 to minus 3 degrees |
| Trendelenburg and reverse | Minus 17 to plus 17 degrees |
| Siderail type | Full-length tubular, both sides |
| Siderail height | 39.3 cm |
| Castors | 150 mm |
| Braking | Central brake and steer, foot operated |
| Controls | Integrated in siderails |
| Protection class | IPX4 |
| Power | Mains electric |
| Setting | Acute wards, nursing homes, long-term care |
| Condition | Pre-owned NHS stock, working order |
Model variant
The figures above match the Hill-Rom 900 bed platform. The 900 range was supplied in several configurations that differ in siderail style, castor specification, control layout and fitted options, and the exact variant of this unit has not been confirmed from a rating label. The bed is offered on the basis of the specification and photographs shown. Fitted options also vary between units from the same platform, so where a specific variant or option is essential, ask before ordering and the rating label and configuration will be checked.
Siderails, mattress fit and entrapment risk
Bed rails only reduce risk when the rail, the bed frame and the mattress are dimensionally compatible. A mattress that is too thin, too soft at the edges or too small for the deck leaves gaps at the rail, within the rail and between rail and mattress that a patient can become trapped in. Check the effective rail height above the compressed mattress surface and check every gap against current national guidance on the safe use of bed rails, and reassess whenever the mattress is changed, including any move to a dynamic or overlay surface. Bed rails are not appropriate for every patient and their use should follow an individual risk assessment rather than a routine default.
Delivery and access
| Component | Action | Interval |
|---|---|---|
| Siderails | Check latching, movement and integrity, confirm gaps against the mattress in use | Before each use |
| Brakes and castors | Confirm the central brake holds, clear debris and thread from castor spindles | Weekly |
| Profiling functions | Cycle height, backrest, thigh and tilt through full travel and listen for actuator strain | Weekly |
| Mains lead and controls | Inspect the lead, plug and control panels for damage and fluid ingress | Weekly |
| Mattress and cover | Decontaminate per local policy, inspect the cover for rips, staining and seam failure | Between patients |
| Frame and fixings | Inspect for cracks, corrosion, loose fasteners and deformation | Monthly |
| Planned maintenance and electrical safety test | Engineer service and test | Per local schedule |
The above is general guidance. The manufacturer instructions for use and the operating organisation's decontamination and maintenance policy take precedence. Any bed showing a fault should be taken out of service until it has been repaired and re-tested.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article