Arjo Tenor Bariatric Mobile Patient Hoist with Weighing Scale
£449.99
This item
Arjo Huntleigh Maxi Move III Patient Hoist with Battery
£300.00
The Arjo Tenor is a heavy duty mobile floor lifter built for plus-size and bariatric transfers, with a safe working load of 320 kg. That capacity places it at the top of the mobile hoist range and is the reason services keep one on the ward rather than hiring in when a bariatric admission arrives. The curved jib clears the patient and allows full 360 degree rotation once lifted, and the four point bariatric spreader bar widens the gap between shoulder and leg hooks so the sling distributes load rather than squeezing. This unit carries the integrated suspended weighing scale, so a weight is captured during the transfer instead of becoming a separate procedure that often does not happen at all in bariatric care. Supplied with a pre-owned battery. Sling and charger are sold separately.
| Item | Detail | Condition |
|---|---|---|
| Arjo Tenor hoist | Bariatric mobile floor lifter with curved jib and width-adjustable chassis legs | USED |
| Integrated weighing scale | Suspended scale fitted to the hoist | USED |
| Four point bariatric spreader bar | Wide-gap spreader bar for shoulder and leg hooks | USED |
| Battery | Sealed lead acid 24 V 4 Ah, part number NDA0100-20 | USED |
| Hand control | Handset for lift and lower | USED |
| Item | Detail | Status |
|---|---|---|
| Slings | Selected by weight, body distribution, height and physical condition | SOLD SEPARATELY |
| Battery charger | Charging unit for the 24 V battery | ADD-ON |
| Spare battery | Second pack for rotation between charges | SOLD SEPARATELY |
| Scale verification | Calibration check of the weighing function against a certified reference | SOLD SEPARATELY |
| Thorough examination | Six monthly examination by a competent person under LOLER 1998 | SOLD SEPARATELY |
| Service and inspection | Engineer service and load testing | SOLD SEPARATELY |
Mandatory before any use with a patient
Pre-owned battery, no charger supplied
The battery is pre-owned. Capacity in any sealed lead acid pack falls with age and cycle count, so the number of lifts available from a full charge cannot be stated for this unit and must be assessed once it is on charge. No charger is supplied, so a charger must be in place before the hoist can be brought into service. Where a bariatric caseload depends on the hoist being available at short notice, a fresh battery and a second pack on rotation are worth budgeting for. The battery is a sealed lead acid 24 V 4 Ah pack, part number NDA0100-20.
Weighing scale accuracy
The integrated scale is a measuring function on a pre-owned device and its accuracy has not been verified here. Before any weight from this hoist is used for a clinical decision, particularly weight-based drug dosing, the scale should be checked against a certified reference by a qualified engineer and then verified at the interval set by the operating organisation.
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. This item may require service and calibration. A full engineer service, load test, scale verification and thorough examination are not included unless this listing states that the unit has been serviced. Ongoing inspection and six monthly thorough examination remain with the operating organisation once the equipment is in service.
| Manufacturer | Arjo, formerly ArjoHuntleigh |
| Model | Tenor with weighing scale |
| Device type | Bariatric mobile patient hoist, floor lifter |
| Safe working load | 320 kg |
| Hoist weight, without battery, with scale | 66.4 kg |
| Hoisting range | 1225 mm |
| Minimum central suspension point height | 800 mm |
| Maximum height at maximum hoisting reach | 1405 mm |
| Maximum height, legs spread | 2025 mm |
| Minimum wall distance at maximum reach, legs spread | 335 mm |
| Minimum wall distance at minimum height, legs spread | 530 mm |
| Turning radius | 1650 mm |
| Spreader bar | Four point bariatric |
| Weighing scale | Suspended, integrated |
| Battery | Sealed lead acid, 24 V, 4 Ah, part number NDA0100-20 |
| Ingress protection | IPX4 |
| Electrical classification | Internally powered equipment, Type B applied part |
| Standards | EN and IEC 60601-1 |
| Condition | Pre-owned |
Delivery and access
| Component | Action | Interval |
|---|---|---|
| Slings | Inspect webbing, stitching, loops and labels, withdraw any sling showing fraying or damage | Before each use |
| Spreader bar and hooks | Check hooks, latches and attachment points for wear and distortion | Before each use |
| Battery | Return to charge after use, check the discharge indicator, note any fall in the number of lifts | After each use |
| Brakes and castors | Confirm the brakes hold, clear hair and debris from the castor spindles | Weekly |
| Emergency lowering | Confirm the override operates | Weekly |
| Mast, jib and chassis | Inspect for cracks, corrosion, loose fasteners and leg adjustment function | Monthly |
| Weighing scale | Check against a known reference weight per local policy | Per local schedule |
| Thorough examination | Formal examination by a competent person under LOLER 1998 | At least every six months |
The above is general guidance. The manufacturer instructions for use and the operating organisation's moving and handling policy take precedence. Any hoist showing damage or a fault should be taken out of service until it has been inspected and repaired.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article