24/7 Chat Available
24/7 Chat Available
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Add the whole set in one go.
Arjo Sara Stedy Patient Stand Aid with Leg Spreader
£469.99
This item
The Arjo Sara Stedy is a non-powered stand and transfer aid that lets a single carer help a patient rise from sitting and move a short distance. The patient stands on the platform holding the central frame, the seat paddles fold down behind them to take their weight in a semi-sitting position, and the carer moves the unit to a bed, chair, toilet or basin.
This unit has a leg spreader. The base legs open to widen the footprint, so the Sara Stedy can be brought in close around a chair, a commode or a wheelchair and the patient can stand from a seated position without shuffling forward first. On a fixed-base Sara Stedy the unit has to stop short of anything wider than its own base, and the leg spreader is what removes that restriction.
The Sara Stedy keeps the patient working. A wheelchair transfer asks nothing of the patient and a hoist takes over the movement, whereas the Sara Stedy asks them to stand and hold on, which maintains leg strength and confidence while the frame makes it safe for the carer to support them. By redistributing the patient's weight onto the frame, it reduces the force the carer has to apply and with it the risk of carer injury. The transfer happens face to face at eye level, which matters for communication and dignity during toileting and personal care.
Low friction castors make the unit easy to steer, and two rear brakes hold it still while the patient stands and sits. The safe working load is 182 kg.
| Item | Detail |
|---|---|
| Manufacturer | Arjo, formerly ArjoHuntleigh |
| Product | Sara Stedy stand and transfer aid |
| Configuration | With leg spreader |
| Related configuration | Sara Stedy with fixed base, no leg spreader, a different unit |
Patient selection. The Sara Stedy is for patients who can bear weight through their legs, hold the frame and rise from sitting with support. It is not suitable for a patient who cannot stand, cannot hold on, or cannot follow simple instruction, and for them a hoist is the appropriate equipment. It is a transfer aid for short distances within a room or area, not a walking aid and not a means of transporting a patient along corridors or between floors. Selection is a clinical decision recorded in the patient's moving and handling assessment.
Safe use of the leg spreader and brakes. Open the legs before approaching the chair or commode, position the unit, then apply both rear brakes before the patient stands. The patient places both feet on the platform before the seat paddles are lowered, and the paddles are raised only once the patient is standing securely. Close the legs again before moving through a doorway. Move slowly on level floors, avoid thresholds, slopes and uneven surfaces with a patient on board, and read the safe working load from this unit's own label before use.
Condition and inspection. This unit is pre-owned and supplied without a service history. Check the frame, platform, seat paddles, handles, leg spreader mechanism, castors and brakes for damage and correct operation before first use, and inspect routinely to the manufacturer's instructions and local policy thereafter. Duties under PUWER 1998 apply to equipment used at work. Clean between patients with a disinfectant compatible with the frame and grips.
Specifications can change without notice. Ask us for the current technical file.
Further documentation is available on request.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article